IF55 ROT CANopen®
1010-01 Store parameters
[Unsigned32, rw]
This object is used to save all parameters on non-volatile memory.
Write "
save
" (ASCII code in hexadecimal format) in the data bytes:
Master
Slave
COB-ID
Cmd
Index
Sub
Data bytes
600+ID
23
10
10
01
73
61
76
65
s
a
v
e
Slave
Master (confirmation)
COB-ID
Cmd
Index
Sub
Data bytes
580+ID
60
10
10
01
00
00
00
00
1011-01 Restore default parameters
[Unsigned32, rw]
This object allows the operator to restore all parameters to default values
(default values are set at the factory by Lika Electronic engineers to allow the
operator to run the device for standard operation in a safe mode).
Write "
load
" (ASCII code in hexadecimal format) in the data bytes and then
issue a
Reset node
command:
Master
Slave
COB-ID
Cmd
Index
Sub
Data bytes
600+ID
23
11
10
01
6C
6F
61
64
l
o
a
d
Slave
Master (confirmation)
COB-ID
Cmd
Index
Sub
Data bytes
580+ID
60
11
10
01
00
00
00
00
Master
Slave (
Reset node
)
COB-ID
Cmd
Slave ID
000
81
ID
Slave
Master (Boot-up)
COB-ID
Cmd
700+ID
00
NOTE
Save the default values after upload using the store parameters function (see
the
object).
MAN IF55 ROT CB E 1.2.odt
6 - CANopen® interface (DS 406)
49 of 88