IF55 ROT CANopen®
because of an file error).
0800 0024h
No data available
6.10 Emergency (EMCY) objects
Emergency (EMCY) objects are triggered by the device when an internal error
occurs.
Structure of the EMCY message:
IDENTIFIER
CAN Data Byte
COB-ID(hex)
0
1
2
3…7
see the
object
Error code
Error Sub-
register
Specific code
LSB
MSB
01
00…00
Available error codes indicated by CANopen but not necessarily supported by
the manufacturer:
Error code
Description
0000h
Error reset or no error
1000h
Generic error,
Node guarding error
2000h
Current – generic error
2100h
Current, CANopen device input side – generic
2200h
Current inside the CANopen device – generic
2300h
Current, CANopen device output side – generic
3000h
Voltage – generic error
3100h
Mains voltage – generic
3200h
Voltage inside the CANopen device – generic
3300h
Output voltage – generic
4000h
Temperature – generic error
4100h
Ambient temperature – generic
4200h
Device temperature – generic
5000h
CANopen device hardware – generic error
5530h
Flash memory error
6000h
CANopen device software – generic error
6100h
Internal software – generic
6200h
User software – generic
6300h
Data set – generic