Configuration
2−73
l
EDSVF9383V−EXT EN 2.0
2.4.16.4
Function 4: |CMP1−IN1| = |CMP1−IN2|
l
Selection: C0680 = 4
l
This function is used to carry out the comparison "|n
act.
| = |n
x
|" for instance.
l
This function is the same as function 1. (
¶
– However, the absolute value of the input signals (without sign) is created before the signals
are processed.
2.4.16.5
Function 5: |CMP1−IN1| > |CMP1−IN2|
l
Selection: C0680 = 5
l
This function is used to carry out the comparison "|n
act.
| > |n
x
|" independently of the direction
of rotation.
l
This function is the same as function 3. (
¶
– However, the absolute value of the input signals (without sign) is created before the signals
are processed.
2.4.16.6
Function 6: |CMP1−IN1| < |CMP1−IN2|
l
Selection: C0680 = 6
l
This function is the same as function 2. (
¶
– However, the absolute value of the input signals (without sign) is created before the signals
are processed.
l
This function is used to carry out the comparison "|n
act.
| < |n
x
|" independently of the direction
of rotation.
Содержание 9300 vector Series
Страница 8: ...Preface Definition of notes used 1 6 l EDSVF9383V EXT EN 2 0...
Страница 188: ...Application examples Centre winder with internal diameter calculation 3 18 l EDSVF9383V EXT EN 2 0...
Страница 192: ...Signal flow charts Speed control 4 4 l EDSVF9383V EXT EN 2 0 Fig 4 1 Basic configuration 1000 speed control sheet 1...
Страница 205: ...Signal flow charts Step control 4 17 l EDSVF9383V EXT EN 2 0 Fig 4 13 Basic configuration 2000 step control sheet 1...
Страница 211: ...Signal flow charts Torque control 4 23 l EDSVF9383V EXT EN 2 0 Fig 4 17 Basic configuration 4000 torque control sheet 1...