Configuration
2−131
l
EDSVF9383V−EXT EN 2.0
2.4.44.3
Initialization of the motor potentiometer
Under C0265, you can activate different initialization functions for the mains switch−on.
l
C0265 = 0
– The current output value is saved before mains disconnection or mains failure. The motor
potentiometer starts with this value after mains connection.
l
C0265 = 1
– The motor potentiometer starts with the lower limit (C0261) after mains connection.
l
C0265 = 2
– The motor potentiometer starts with 0% after mains connection.
If the initialization is completed, the motor potentiometer follows the applied control function.