Configuration
2−80
l
EDSVF9383V−EXT EN 2.0
2.4.20
Dead band (DB)
This FB eliminates input signals around the zero point (e.g. disturbances on analog input voltages).
DB1
DB1-OUT
DB1-IN
C0623
C0622
±199.99 %
C0621
C0620
Fig. 2−67
Dead band (DB1)
Signal
Source
Note
Name
Type
DIS
DIS format
CFG
List
Lenze
DB1−IN
a
C0623
dec [%]
C0622
1
1000
−
DB1−OUT
a
−
−
−
−
−
limited to ±199.99 %
Function
C0621
C0620
DB1
−
in
DB1
−
OUT
Fig. 2−68
Dead band and gain
l
Under C0621 you can set the parameters for the dead band.
l
Under C0620 you can alter the gain.