Configuration
2−153
l
EDSVF9383V−EXT EN 2.0
2.4.53
CW/CCW/Quick stop (R/L/Q)
This FB evaluates the input of the direction of rotation protected against wire breakage. If there is no
signal for the direction of rotation, quick stop is released.
C0889/2
C0889/1
R/L/Q
R/L/Q−QSP
R/L/Q−R/L
R/L/Q−R
R/L/Q−L
C0885
C0886
Fig. 2−131
CW/CCW/Quick stop (R/L/Q)
Signal
Source
Note
Name
Type
DIS
DIS format
CFG
List
Lenze
R/L/Q−R
d
C0889/1
bin
C0885
2
51
−
R/L/Q−L
d
C0889/2
bin
C0886
2
52
−
R/L/Q−QSP
d
−
−
−
−
−
−
R/L/Q−R/L
d
−
−
−
−
−
−
Function
l
After mains connection, the two outputs are initialized as follows:
Inputs
Outputs
R/L/Q−R
R/L/Q−L
R/L/Q−R/L
R/L/Q−QSP
−
−
0
1
0 = LOW
1 = HIGH
l
After the initialization, the following relationship results in dependence of the input signals:
Inputs
Outputs
R/L/Q−R
R/L/Q−L
R/L/Q−R/L
R/L/Q−QSP
0
0
0/1
*
1
1
0
0
0
0
1
1
0
1
1
unchanged
unchanged
0 = LOW
1 = HIGH
*
If you have selected a direction of rotation and then set both inputs to LOW, the signal state at R/L/Q−R/L will not change.
Содержание 9300 vector Series
Страница 8: ...Preface Definition of notes used 1 6 l EDSVF9383V EXT EN 2 0...
Страница 188: ...Application examples Centre winder with internal diameter calculation 3 18 l EDSVF9383V EXT EN 2 0...
Страница 192: ...Signal flow charts Speed control 4 4 l EDSVF9383V EXT EN 2 0 Fig 4 1 Basic configuration 1000 speed control sheet 1...
Страница 205: ...Signal flow charts Step control 4 17 l EDSVF9383V EXT EN 2 0 Fig 4 13 Basic configuration 2000 step control sheet 1...
Страница 211: ...Signal flow charts Torque control 4 23 l EDSVF9383V EXT EN 2 0 Fig 4 17 Basic configuration 4000 torque control sheet 1...