Configuration
2−57
l
EDSVF9383V−EXT EN 2.0
2.4.10
Analog outputs via terminals X6/62 and X6/63 (AOUT)
These FB are used to output internal analog signals as voltage signals and e.g. display values or
setpoints for slaves.
62
AOUT1
C434/1
+
+
AOUT1−IN
AOUT1−GAIN
AOUT1−OFFSET
C0434/3
C0434/2
C0431
C0433
C0432
X6
Fig. 2−36
Analog output via terminal X6/62 (AOUT1)
Signal
Source
Note
Name
Type
DIS
DIS format
CFG
List
Lenze
AOUT1−IN
a
C0434/1
dec [%]
C0431
1
5001
−
AOUT1−OFFSET
a
C0434/2
dec [%]
C0432
1
19512
−
AOUT1−GAIN
a
C0434/3
dec [%]
C0433
1
19510
−
63
AOUT2
C439/1
+
+
AOUT2−IN
AOUT2−GAIN
AOUT2−OFFSET
C0439/3
C0439/2
C0436
C0438
C0437
X6
Fig. 2−37
Analog output via terminal X6/63 (AOUT2)
Signal
Source
Note
Name
Type
DIS
DIS format
CFG
List
Lenze
AOUT2−IN
a
C0439/1
dec [%]
C0436
1
5002
−
AOUT2−OFFSET
a
C0439/2
dec [%]
C0437
1
19513
−
AOUT2−GAIN
a
C0439/3
dec [%]
C0438
1
19511
−
Содержание 9300 vector Series
Страница 8: ...Preface Definition of notes used 1 6 l EDSVF9383V EXT EN 2 0...
Страница 188: ...Application examples Centre winder with internal diameter calculation 3 18 l EDSVF9383V EXT EN 2 0...
Страница 192: ...Signal flow charts Speed control 4 4 l EDSVF9383V EXT EN 2 0 Fig 4 1 Basic configuration 1000 speed control sheet 1...
Страница 205: ...Signal flow charts Step control 4 17 l EDSVF9383V EXT EN 2 0 Fig 4 13 Basic configuration 2000 step control sheet 1...
Страница 211: ...Signal flow charts Torque control 4 23 l EDSVF9383V EXT EN 2 0 Fig 4 17 Basic configuration 4000 torque control sheet 1...