Configuration
2−110
l
EDSVF9383V−EXT EN 2.0
2.4.37
Integrator (INT)
These FBs calculate an angle of rotation from a speed signal. The angle of rotation is output as phase
signal and analog signal.
INT1-IN
INT1-RESET
C1355
C1356
INT1-AOUT
± 199.99 %
C1358
C1359
C1351
INT1
INT1-POUT
± 32000 rev.
INT1-REF
C1354
C1357
C1350
INT1-DOUT
Fig. 2−89
Integrator (INT1)
Signal
Source
Note
Name
Type
DIS
DIS format
CFG
List
Lenze
INT1−REF
ph
C1357
dec [inc]
C1354
3
1000
−
INT1−IN
phd
C1358
dec [rpm]
C1355
4
1000
−
INT1−RESET
d
C1359
bin
C1356
2
1000
HIGH = sets the integrator to zero
INT1−DOUT
d
−
−
−
−
−
−
INT1−POUT
ph
−
−
−
−
−
−
INT1−AOUT
a
−
−
−
−
−
limited to ±199.99 %
C1365
C1366
INT2-AOUT
± 199.99 %
C1368
C1369
C1361
INT2
INT2-POUT
± 32000 rev.
INT2-REF
C1364
C1367
C1360
INT2-DOUT
Fig. 2−90
Integrator (INT2)
Signal
Source
Note
Name
Type
DIS
DIS format
CFG
List
Lenze
INT2−REF
ph
C1367
dec [inc]
C1364
3
1000
−
INT2−IN
phd
C1368
dec [rpm]
C1365
4
1000
−
INT2−RESET
d
C1369
bin
C1366
2
1000
HIGH = sets the integrator to zero
INT2−DOUT
d
−
−
−
−
−
−
INT2−POUT
ph
−
−
−
−
−
−
INT2−AOUT
a
−
−
−
−
−
limited to ±199.99 %
Range of functions
l
Output angle of rotation as phase signal
l
Compare angle of rotation with reference value
l
Output angle of rotation as analog signal
l
Phase signal reset
Содержание 9300 vector Series
Страница 8: ...Preface Definition of notes used 1 6 l EDSVF9383V EXT EN 2 0...
Страница 188: ...Application examples Centre winder with internal diameter calculation 3 18 l EDSVF9383V EXT EN 2 0...
Страница 192: ...Signal flow charts Speed control 4 4 l EDSVF9383V EXT EN 2 0 Fig 4 1 Basic configuration 1000 speed control sheet 1...
Страница 205: ...Signal flow charts Step control 4 17 l EDSVF9383V EXT EN 2 0 Fig 4 13 Basic configuration 2000 step control sheet 1...
Страница 211: ...Signal flow charts Torque control 4 23 l EDSVF9383V EXT EN 2 0 Fig 4 17 Basic configuration 4000 torque control sheet 1...