Configuration
Use of funktion blocks
2−38
l
EDSVF9383V−EXT EN 2.0
Removing connections
l
Since a source may have several targets, there may be additional signal connections, which
may under certain conditions not be wanted.
l
Example:
– In the default setting of the basic configuration C0005 = 1000 (speed control) ASW1−IN1 and
AIN2−OUT are connected.
– The above−taken steps do not automatically deactivate this connection! If the connection is
not desired, it must be removed.
+
−
*
/
x/(1
−
y)
C0600
x
y
ARIT2
ARIT2
−
OUT
C0602/1
"
200%
C0602/2
ARIT2
−
IN1
ARIT2
−
IN2
C0601/1
C0601/2
62
AOUT1
C434/1
+
+
AOUT1
−
IN
AOUT1
−
GAIN
AOUT1
−
OFFSET
C0434/3
C0434/2
C0431
C0433
C0432
3
4
AIN2
+
+
AIN2
−
OUT
AIN2
−
GAIN
AIN2
−
OFFSET
C0409/1
C0409/2
C0407
C0408
C0108/1
C0109/1
C0027/2
C0026/2
ASW1
−
IN1
C0812/1
1
0
C0812/2
ASW1
−
SET
ASW1
−
IN2
ASW1
ASW1
−
OUT
C0813
C0810/1
C0810/2
C0811
FIXED0
FIXED0%
NSET
−
NADD
Fig. 2−18
Removing connections in a configuration
6. Remove the connection between ASW1−IN1 and AIN2−OUT:
– Use
z
or
y
to select C0810/1
– Press PRG to go to the parameter level.
– Use
z
or
y
to select the constant FIXED0% (selection number 1000).
– Confirm with SH + PRG.
– Press PRG to go back to the code level.
The connection has now been removed.
7. Save the new configuration, if necessary:
– Use C0003 and save the new signal configuration in a parameter set to ensure that the
changes will not get lost after mains switching.
Содержание 9300 vector Series
Страница 8: ...Preface Definition of notes used 1 6 l EDSVF9383V EXT EN 2 0...
Страница 188: ...Application examples Centre winder with internal diameter calculation 3 18 l EDSVF9383V EXT EN 2 0...
Страница 192: ...Signal flow charts Speed control 4 4 l EDSVF9383V EXT EN 2 0 Fig 4 1 Basic configuration 1000 speed control sheet 1...
Страница 205: ...Signal flow charts Step control 4 17 l EDSVF9383V EXT EN 2 0 Fig 4 13 Basic configuration 2000 step control sheet 1...
Страница 211: ...Signal flow charts Torque control 4 23 l EDSVF9383V EXT EN 2 0 Fig 4 17 Basic configuration 4000 torque control sheet 1...