Configuration
Basic configuration
2−11
l
EDSVF9383V−EXT EN 2.0
M
M
0
1
9300VEC010
Fig. 2−3
Basic structure of a step controller for a bulk material filling station
0
Dosing drive
1
Conveyor drive
Input and output assignment
Dosing drive
Conveyor drive
Analog inputs
·
Dosing speed
·
Dosing amount
·
Conveyor speed
·
Step width
Digital inputs
·
Controller enable
·
Direction of rotation
·
Defined dosing amount
·
Start dosing
·
TRIP reset
·
Controller enable
·
Step direction
·
Defined step width
·
Start step
·
TRIP reset
Digital outputs
·
Error (TRIP)
·
Current speed
>
C0017 (Qmin)
·
Ready for operation (RDY)
·
Dosing completed
·
Error (TRIP)
·
Current speed
>
C0017 (Qmin)
·
Ready for operation (RDY)
·
Step completed
Analog outputs
·
Actual speed
·
Motor current
·
Actual speed
·
Motor current