Configuration
Basic configuration
2−7
l
EDSVF9383V−EXT EN 2.0
2.2.3
Speed control (C0005 = 1000)
The configuration C0005 = 1000 (Lenze setting) has mainly been designed for single drives. The
setpoint speed for the drive is selected via the analog input X6/1. The signals are internally
conditioned together with the digital control signals.
Short setup
The "Short setup" menu contains the following codes. In the "Short setup" menu of the XT keypad
and "Global Drive Control", the codes are listed in the following order.
Code
Explanation
Lenze setting
C0005
Selection of the basic configuration
1000
C0010
Minimum speed
Reference value for the absolute and relative setpoint selection for the
acceleration and deceleration times
0 rpm
C0011
Maximum speed
3000 rpm
C0012
Acceleration time T
ir
of the main setpoint
5.00 s
C0013
Deceleration time T
if
of the main setpoint
5.00 s
C0034
Voltage / current range for analog signals at the input X6/1, X6/2
0
C0104
Selection of acceleration function of the linear ramp−function generator of NSET
0
C0038/1 ... C0038/6
Suppressing the speed ranges, function block NLIM1
0
C0039/1
JOG setpoints for the speed setpoint conditioning, function block NSET
1500 rpm
C0190
Arithmetic function, function block NSET
Connects main setpoint (C0046) and additional setpoint (C0040)
0
C0220
Acceleration time T
ir
for additional setpoint, function block NSET
2.00 s
C0221
Deceleration time T
if
for additional setpoint, function block NSET
2.00 s
C0105
Quick stop deceleration time
5.00 s
C0909
Speed limitation, function block MCTRL
1
C0026/1
Offset of AIN1 (X6/1, X6/2)
0.00 %
C0026/2
Offset of AIN2 (X6/3, X6/4)
0.00 %
C0027/1
Gain AIN1 (X6/1, X6/2)
100.00 %
C0027/2
Gain AIN2 (X6/3, X6/4)
100.00 %
C0006
Selection of the operating mode for the motor control
5
C0025
Speed feedback
1
C0019
Operating threshold − automatic DC injection brake (Auto−GSB)
0 rpm
C0036
Set continuous brake current
0.0 A
C0107
Hold time for automatic DC injection braking (Auto−GSB)
0.00 s
C0142
Start conditions for flying restart circuit
1
C0145
Selection of flying restart method
1
C0070
Speed controller gain
10.0
C0071
Adjustment time of speed controller
50 ms
C0074
Limitation of the speed controller
10.00 %
C0077
Adjustment time of field controller
4.0 ms
C0898
Torque limitation in the field weakening range, function block MCTRL
0
C0472/3
Free control code for analog signals
100.00%
C0017
Q
min
switching threshold
50 rpm
Содержание 9300 vector Series
Страница 8: ...Preface Definition of notes used 1 6 l EDSVF9383V EXT EN 2 0...
Страница 188: ...Application examples Centre winder with internal diameter calculation 3 18 l EDSVF9383V EXT EN 2 0...
Страница 192: ...Signal flow charts Speed control 4 4 l EDSVF9383V EXT EN 2 0 Fig 4 1 Basic configuration 1000 speed control sheet 1...
Страница 205: ...Signal flow charts Step control 4 17 l EDSVF9383V EXT EN 2 0 Fig 4 13 Basic configuration 2000 step control sheet 1...
Страница 211: ...Signal flow charts Torque control 4 23 l EDSVF9383V EXT EN 2 0 Fig 4 17 Basic configuration 4000 torque control sheet 1...