Configuration
2−143
l
EDSVF9383V−EXT EN 2.0
Function
ORx−IN1
ORx−IN2
ORx−IN3
ORx−OUT
0
0
0
0
1
0
0
0
0
1
0
0
1
1
0
0
0
0
1
0
1
0
1
0
0
1
1
0
1
1
1
1
0 = LOW
1 = HIGH
In a contactor control, the function corresponds to a parallel connection of normally−open contacts.
ORx
−
IN2
ORx
−
IN1
ORx
−
IN3
ORx
−
OUT
Fig. 2−119
Function of the OR operation as a parallel connection of normally−open contacts
Tip!
If only two inputs are required, use the inputs ORx−IN1 and ORx−IN2. Assign the input ORx−IN3 with
the signal source FIXED0.