Application examples
Dosing drive for a filling station
3−6
l
EDSVF9383V−EXT EN 2.0
3.4
Dosing drive for a filling station
This application is based on the basic configuration C0005 = 2000.
Q
R
Fig. 3−4
Basic structure of a step controller for a bulk material filling station
Dosing drive
Conveyor drive
Input and output assignment
Dosing drive
Conveyor drive
Analog inputs
X6/1,2
·
Dosing speed
·
Conveyor speed
X6/3,4
·
Dosing amount
·
Step width
Digital inputs
X5/28
·
Controller enable
·
Controller enable
X5/E1, X5/E2
·
Direction of rotation/quick stop
·
Step direction/quick stop
X5/E3
·
Fixed dosing amount
·
Fixed step width
X5/E4
·
Start dosing
·
Start step
X5/E5
·
TRIP reset
·
TRIP reset
Digital outputs
X5/A1
·
Error (TRIP)
·
Error (TRIP)
X5/A2
·
Current speed
>
C0017 (Qmin)
·
Current speed > C0017 (Q
min
)
X5/A3
·
Ready for operation (RDY)
·
Ready for operation (RDY)
X5/A4
·
Dosing completed
·
Step completed
Analog outputs
X6/62
·
Actual speed
·
Actual speed
X6/63
·
Motor current
·
Motor current
Tip!
If the required amount has not yet been reached at the end of dosing, you can control redosing via
the setpoint.
Содержание 9300 vector Series
Страница 8: ...Preface Definition of notes used 1 6 l EDSVF9383V EXT EN 2 0...
Страница 188: ...Application examples Centre winder with internal diameter calculation 3 18 l EDSVF9383V EXT EN 2 0...
Страница 192: ...Signal flow charts Speed control 4 4 l EDSVF9383V EXT EN 2 0 Fig 4 1 Basic configuration 1000 speed control sheet 1...
Страница 205: ...Signal flow charts Step control 4 17 l EDSVF9383V EXT EN 2 0 Fig 4 13 Basic configuration 2000 step control sheet 1...
Страница 211: ...Signal flow charts Torque control 4 23 l EDSVF9383V EXT EN 2 0 Fig 4 17 Basic configuration 4000 torque control sheet 1...