Configuration
2−95
l
EDSVF9383V−EXT EN 2.0
2.4.29
Digital outputs (DIGOUT)
This FB conditions digital signals and output them at terminals X5/A1 ... X5/A4.
A1
A2
A3
A4
1
0
C0118/1...4
DIGOUT
DIGOUT1
DIGOUT2
DIGOUT3
C0117/1
C0117/2
C0117/3
C0117/4
C0444/4
C0444/3
C0444/2
C0444/1
X5
1
DIGOUT4
Fig. 2−76
Digital outputs (DIGOUT)
Signal
Source
Note
Name
Type
DIS
DIS format
CFG
List
Lenze
DIGOUT1
d
C0444/1
bin
C0117/1
2
15000
−
DIGOUT2
d
C0444/2
bin
C0117/2
2
10650
−
DIGOUT3
d
C0444/3
bin
C0117/3
2
500
−
DIGOUT4
d
C0444/4
bin
C0117/4
2
5003
−
Function
The terminals X5/A1 to X5/A4 are updated every millisecond. The level for every output can be
inverted.
l
Select the desired output under C0118 with the corresponding subcode (e.g. subcode
C0118/3 for output X5/A3)
l
Select the desired level:
−
0 = Level not inverted (HIGH active)
−
1 = Level inverted (LOW active)
Содержание 9300 vector Series
Страница 8: ...Preface Definition of notes used 1 6 l EDSVF9383V EXT EN 2 0...
Страница 188: ...Application examples Centre winder with internal diameter calculation 3 18 l EDSVF9383V EXT EN 2 0...
Страница 192: ...Signal flow charts Speed control 4 4 l EDSVF9383V EXT EN 2 0 Fig 4 1 Basic configuration 1000 speed control sheet 1...
Страница 205: ...Signal flow charts Step control 4 17 l EDSVF9383V EXT EN 2 0 Fig 4 13 Basic configuration 2000 step control sheet 1...
Страница 211: ...Signal flow charts Torque control 4 23 l EDSVF9383V EXT EN 2 0 Fig 4 17 Basic configuration 4000 torque control sheet 1...