Configuration
2−55
l
EDSVF9383V−EXT EN 2.0
Function
ANDx−IN1
ANDx−IN2
ANDx−IN3
ANDx−OUT
0
0
0
0
1
0
0
0
0
1
0
0
1
1
0
0
0
0
1
0
1
0
1
0
0
1
1
0
1
1
1
1
0 = LOW
1 = HIGH
In a contactor control, the function corresponds to a series connection of normally−open contacts.
ANDx
−
IN1
ANDx
−
IN2
ANDx
−
IN3
ANDx
−
OUT
Fig. 2−33
AND function as a series connection of normally−open contacts
Tip!
If only two inputs are required, use the inputs ANDx−IN1 and ANDx−IN2. Assign the input ANDx−IN3
to the signal source FIXED1.