Configuration
2−72
l
EDSVF9383V−EXT EN 2.0
2.4.16.2
Function 2: CMP1−IN1 > CMP1−IN2
l
Selection: C0680 = 2
l
This function is used to find out whether the actual speed is higher than a limit value (n
act.
>
n
x
)" for one direction of rotation.
CMP1
−
OUT
CMP1
−
IN1
CMP1
−
IN2
1
0
C0681
CMP1
−
IN2
C0681
t
CMP1
−
IN1
t
CMP1
−
OUT
Fig. 2−55
Exceeding signal values (CMP1−IN1 > CMP1−IN2)
Function procedure
1. If the value at CMP1−IN1 exceeds the value at CMP1−IN2, CMP1−OUT changes from LOW to
HIGH.
2. If the value at CMP1−IN1 undershoots the value at CMP1−IN2 minus C0681 again, CMP1−OUT
changes from HIGH to LOW.
2.4.16.3
Function 3: CMP1−IN1 < CMP1−IN2
l
Selection: C0680 = 3
l
This function is used to find out whether the actual speed is lower than a limit value (n
act.
<
n
x
)" for one direction of rotation.
CMP1
−
OUT
CMP1
−
IN1
CMP1
−
IN2
1
0
C0681
CMP1
−
IN2
C0681
t
CMP1
−
IN1
t
CMP1
−
OUT
Fig. 2−56
Undershooting signal values (CMP1−IN1 < CMP1−IN2)
Function procedure
1. If the value at CMP1−IN1 falls below the value at CMP1−IN2, CMP1−OUT changes from LOW
to HIGH.
2. If the value at CMP1−IN1 exceeds the value at CMP1−IN2 plus C0681 again, CMP1−OUT
changes from HIGH to LOW.
Содержание 9300 vector Series
Страница 8: ...Preface Definition of notes used 1 6 l EDSVF9383V EXT EN 2 0...
Страница 188: ...Application examples Centre winder with internal diameter calculation 3 18 l EDSVF9383V EXT EN 2 0...
Страница 192: ...Signal flow charts Speed control 4 4 l EDSVF9383V EXT EN 2 0 Fig 4 1 Basic configuration 1000 speed control sheet 1...
Страница 205: ...Signal flow charts Step control 4 17 l EDSVF9383V EXT EN 2 0 Fig 4 13 Basic configuration 2000 step control sheet 1...
Страница 211: ...Signal flow charts Torque control 4 23 l EDSVF9383V EXT EN 2 0 Fig 4 17 Basic configuration 4000 torque control sheet 1...