A-2
Events and Messages
w
Table A.2
Event Messages
Number Type
Event Text
0x0000
Information
MegaRAID firmware initialization started (PCI ID
%04x/%04x/%04x/%04x)
0x0001
Information
MegaRAID firmware version %s
0x0002
Fatal
Unable to recover cache data from TBBU
0x0003
Information
Cache data recovered from TBBU successfully
0x0004
Information
Configuration cleared
0x0005
Warning
Cluster down; communication with peer lost
0x0006
Information
Virtual drive %s ownership changed from %02x to
%02x
0x0007
Information
Alarm disabled by user
0x0008
Information
Alarm enabled by user
0x0009
Information
Background initialization rate changed to %d%%
0x000a
Fatal
Controller cache discarded due to memory/battery
problems
0x000b
Fatal
Unable to recover cache data due to configuration
mismatch
0x000c
Information
Cache data recovered successfully
0x000d
Fatal
Controller cache discarded due to firmware version
incompatibility
0x000e
Information
Consistency Check rate changed to %d%%
0x000f
Fatal
Fatal firmware error: %s
0x0010
Information
Factory defaults restored
0x0011
Information
Flash downloaded image corrupt
0x0012
Critical
Flash erase error
0x0013
Critical
Flash timeout during erase
0x0014
Critical
Flash error
0x0015
Information
Flashing image: %s
0x0016
Information
Flash of new firmware image(s) complete
0x0017
Critical
Flash programming error
0x0018
Critical
Flash timeout during programming
0x0019
Critical
Flash chip type unknown
0x001a
Critical
Flash command set unknown
0x001b
Critical
Flash verify failure
(Sheet 1 of 13)
Содержание ThinkServer RD230
Страница 1: ...ThinkServer RD230 RD240 and TD230 MegaRAID SAS Software User Guide ...
Страница 2: ......
Страница 3: ...ThinkServer RD230 RD240 and TD230 MegaRAID SAS Software User Guide ...
Страница 16: ...Contents ...
Страница 24: ...Contents ...
Страница 68: ...2 36 Introduction to RAID ...
Страница 252: ...7 10 MegaRAID Storage Manager Window and Menus ...
Страница 262: ...8 10 Configuration Figure 8 5 Virtual Drive Creation Menu The dialog box shown in Figure 8 6 appears ...
Страница 300: ...8 48 Configuration ...
Страница 328: ...9 28 Monitoring System Events and Storage Devices ...
Страница 334: ...10 6 Maintaining and Managing Storage Configurations ...
Страница 360: ...B 12 Glossary ...
Страница 363: ......
Страница 364: ......