4-80
WebBIOS Configuration Utility
•
Select
Fast Init
or
Slow Init
to initialize this virtual drive. A fast
initialization quickly writes zeroes to the first and last 10 Mbyte
regions of the new virtual drive and then completes the initialization
in the background. A slow initialization is not complete until the entire
virtual drive has been initialized with zeroes. It is seldom necessary
to use this option, because the virtual drive was already initialized
when you created it.
Caution:
Before you run an initialization, back up any data on the
virtual drive that you want to save. All data on the virtual
drive is lost when you initialize it.
•
Select
CC
to run a consistency check on this virtual drive. For more
information, see
Section 4.8.1, “Running a Consistency Check.”
(This
option is not available for RAID 0 virtual drives.)
In the right panel of the Virtual Drive screen you can change the virtual
drive configuration by adding or removing a drive or by changing the
RAID level.
Caution:
Before you change a virtual drive configuration, back up
any data on the virtual drive that you want to save.
To remove a drive from a virtual drive, select the drive in the small panel
beneath the
Remove drive
option. Then select
Remove drive
and click
Go
at the bottom of the panel.
See
Section 4.8.4, “Migrating the RAID Level of a Virtual Drive”
for
information about adding a drive to a virtual drive or migrating its RAID
level.
4.6.3
Viewing Drive Properties
The Physical Drive screen displays the properties of a selected drive and
enables you to perform operations on the drive. There are two ways to
access the Physical Drive screen:
•
On the main menu screen, click on a drive in the right panel under
the heading
Physical Drives
.
•
On the main menu screen, click on
Physical Drives
in the left panel
to display the Physical Drive screen. Then click on a drive in the right
panel. Click on the
Properties
button, and click
Go
. The properties
for the selected drive displays.
Содержание ThinkServer RD230
Страница 1: ...ThinkServer RD230 RD240 and TD230 MegaRAID SAS Software User Guide ...
Страница 2: ......
Страница 3: ...ThinkServer RD230 RD240 and TD230 MegaRAID SAS Software User Guide ...
Страница 16: ...Contents ...
Страница 24: ...Contents ...
Страница 68: ...2 36 Introduction to RAID ...
Страница 252: ...7 10 MegaRAID Storage Manager Window and Menus ...
Страница 262: ...8 10 Configuration Figure 8 5 Virtual Drive Creation Menu The dialog box shown in Figure 8 6 appears ...
Страница 300: ...8 48 Configuration ...
Страница 328: ...9 28 Monitoring System Events and Storage Devices ...
Страница 334: ...10 6 Maintaining and Managing Storage Configurations ...
Страница 360: ...B 12 Glossary ...
Страница 363: ......
Страница 364: ......