A-12
Events and Messages
0x0115
Information
CopyBack aborted on PD %s and src is PD %s
0x0116
Information
CopyBack complete on PD %s from PD %s
0x0117
Progress
CopyBack progress on PD %s is %s
0x0118
Information
CopyBack resumed on PD %s from %s
0x0119
Information
CopyBack automatically started on PD %s from %s
0x011a
Critical
CopyBack failed on PD %s due to source %s error
0x011b
Warning
Early Power off warning was unsuccessful
0x011c
Information
BBU FRU is %s
0x011d
Information
%s FRU is %s
0x011e
Information
Controller hardware revision ID %s
0x011f
Warning
Foreign import shall result in a backward incompatible
upgrade of configuration metadata
0x0120
Information
Redundant path restored for PD %s
0x0121
Warning
Redundant path broken for PD %s
0x0122
Information
Redundant enclosure EMM %s inserted for EMM %s
0x0123
Information
Redundant enclosure EMM %s removed for EMM %s
0x0124
Warning
Patrol Read can't be started, as PDs are either not
ONLINE, or are in a VD with an active process, or are
in an excluded VD
0x0125
Information
Copyback aborted by user on PD %s and src is PD %s
0x0126
Critical
Copyback aborted on hot spare %s from %s, as hot
spare needed for rebuild
0x0127
Warning
Copyback aborted on PD %s from PD %s, as rebuild
required in the array
0x0128
Fatal
Controller cache discarded for missing or offline VD %s
When a VD with cached data goes offline or missing
during runtime, the cache for the VD is discarded.
Because the VD is offline, the cache cannot be saved.
0x0129
Information
Copyback cannot be started as PD %s is too small for
src PD %s
0x012a
Information
Copyback cannot be started on PD %s from PD %s, as
SAS/SATA is not supported in an array
0x012b
Information
Microcode update started on PD %s
0x012c
Information
Microcode update completed on PD %s
Table A.2
Event Messages (Cont.)
Number Type
Event Text
(Sheet 11 of 13)
Содержание ThinkServer RD230
Страница 1: ...ThinkServer RD230 RD240 and TD230 MegaRAID SAS Software User Guide ...
Страница 2: ......
Страница 3: ...ThinkServer RD230 RD240 and TD230 MegaRAID SAS Software User Guide ...
Страница 16: ...Contents ...
Страница 24: ...Contents ...
Страница 68: ...2 36 Introduction to RAID ...
Страница 252: ...7 10 MegaRAID Storage Manager Window and Menus ...
Страница 262: ...8 10 Configuration Figure 8 5 Virtual Drive Creation Menu The dialog box shown in Figure 8 6 appears ...
Страница 300: ...8 48 Configuration ...
Страница 328: ...9 28 Monitoring System Events and Storage Devices ...
Страница 334: ...10 6 Maintaining and Managing Storage Configurations ...
Страница 360: ...B 12 Glossary ...
Страница 363: ......
Страница 364: ......