Complete the following steps:
1. Verify that matching Processors are installed in the correct Processor sockets according to the
service information for this product.
2. Check IBM support site for an applicable service bulletin or firmware update that applies to
this Processor error.
3. (Trained Service technician only) Replace the system board.
•
I.2018002 [I.2018002] The device found at Bus % Device % Function % could not be configured
due to resource constraints. The Vendor ID for the device is % and the Device ID is %.
Explanation:
OUT_OF_RESOURCES (PCI Option ROM)
Severity
Info
User Response
Complete the following steps:
1. If this PCIe device and/or any attached cables were recently installed, moved, serviced or
upgraded, reseat adapter and any attached cables.
2. Check IBM support site for any applicable service bulletin or UEFI or adapter firmware update
that applies to this error. NOTE: It may be necessary to disable unused option ROMs from UEFI
F1 setup or ASU or using adapter manufacturer utilities so that adapter firmware can be updated.
3. Move card to a different slot. If slot not available or error re-occurs, replace adapter.
4. (Trained Service technician only) If adapter was moved to a different slot and error did not
re-occur, verify that this is not a system limitation and then replace the system board. Also, if
this is not the initial installation and the error persists after adapter replacement, replace system
board.
•
I.2018003 [I.2018003] A bad option ROM checksum was detected for the device found at Bus %
Device % Function %. The Vendor ID for the device is % and the Device ID is %.
Explanation:
ROM CHECKSUM ERROR
Severity
Error
User Response
Complete the following steps:
1. If this PCIe device and/or any attached cables were recently installed, moved, serviced or
upgraded, reseat adapter and any attached cables.
2. Move adapter to a different system slot, if available.
3. Check IBM support site for any applicable service bulletin or UEFI or adapter firmware update
that applies to this error. NOTE: It may be necessary to configure slot to Gen1 or to use
special utility software so that adapter firmware can be upgraded. Gen1/Gen2 settings can be
configured via F1 Setup -> System Settings -> Devices and I/O Ports -> PCIe Gen1/Gen2/Gen3
Speed Selection, or the ASU Utility.
4.
Replace adapter.
958
Lenovo System x3650 M4 HD Installation and Service Guide
Содержание System x3650 M4 HD
Страница 1: ...Lenovo System x3650 M4 HD Installation and Service Guide Machine Type 5460 ...
Страница 6: ...iv Lenovo System x3650 M4 HD Installation and Service Guide ...
Страница 134: ...122 Lenovo System x3650 M4 HD Installation and Service Guide ...
Страница 178: ...166 Lenovo System x3650 M4 HD Installation and Service Guide ...
Страница 190: ...178 Lenovo System x3650 M4 HD Installation and Service Guide ...
Страница 314: ...302 Lenovo System x3650 M4 HD Installation and Service Guide ...
Страница 964: ...952 Lenovo System x3650 M4 HD Installation and Service Guide ...
Страница 988: ...976 Lenovo System x3650 M4 HD Installation and Service Guide ...
Страница 1146: ...1134 Lenovo System x3650 M4 HD Installation and Service Guide ...
Страница 1150: ...1138 Lenovo System x3650 M4 HD Installation and Service Guide ...
Страница 1157: ...People s Republic of China Class A electronic emission statement Taiwan Class A compliance statement Appendix E Notices 1145 ...
Страница 1158: ...Taiwan BSMI RoHS declaration 1146 Lenovo System x3650 M4 HD Installation and Service Guide ...
Страница 1167: ......
Страница 1168: ......