Lenovo System x3650 M4 HD Скачать руководство пользователя страница 1044

Recoverable

No

Severity

Warning

Serviceable

No

Automatically notify support

No

User Response

Complete the following steps:

1. Perform the actions mentioned one at a time and try the test after each action.

2. If the problem remains, contact your technical-service representative.

3. Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s).

Reconnect it to power.

4. Make sure that DSA and BIOS/uEFI are at the latest level.

Related links

IBM Support website

Latest level of DSA

Latest level of BMC/IMM

201-815-002 : Standalone Memory Test Aborted

Program Error with Quick Memory Menu Option Selection.

Recoverable

No

Severity

Warning

Serviceable

No

Automatically notify support

No

User Response

Complete the following steps:

1. Perform the actions mentioned one at a time and try the test after each action.

2. If the problem remains, contact your technical-service representative.

3. Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s).

Reconnect it to power.

4. Make sure that DSA and BIOS/uEFI are at the latest level.

Related links

IBM Support website

Latest level of DSA

Latest level of BMC/IMM

1032

Lenovo System x3650 M4 HD Installation and Service Guide

Содержание System x3650 M4 HD

Страница 1: ...Lenovo System x3650 M4 HD Installation and Service Guide Machine Type 5460 ...

Страница 2: ...ormation document and the Safety Information and Environmental Notices and User Guide documents on the Lenovo Documentation CD Sixth Edition September 2016 Copyright Lenovo 2015 2016 LIMITED AND RESTRICTED RIGHTS NOTICE If data or software is delivered pursuant to a General Services Administration GSA contract use reproduction or disclosure is subject to restrictions set forth in Contract No GS 35...

Страница 3: ...ing a memory module 43 DIMM installation sequence 46 Memory mirrored channel 46 Memory rank sparing 47 Installing a memory module 48 Installing an adapter 49 Installing an adapter in a PCI riser card assembly 50 Installing an adapter in the rear two hard disk drive kit 52 Installing the ServeRAID adapter memory module 53 Installing a RAID adapter battery or flash power module 54 Installing the dua...

Страница 4: ...Solving Ethernet controller problems 159 Solving undetermined problems 160 Problem determination tips 160 Recovering the server firmware UEFI update failure 162 In band manual recovery method 162 In band automated boot recovery method 164 Out of band method 164 Automated boot recovery ABR 164 Nx boot failure 164 Chapter 5 Parts listing Lenovo System x3650 M4 HD Type 5460 167 Replaceable server com...

Страница 5: ...ppendix D Getting help and technical assistance 1135 Before you call 1135 Using the documentation 1136 Getting help and information from the World Wide Web 1136 How to send DSA data 1136 Creating a personalized support web page 1136 Software service and support 1137 Hardware service and support 1137 Taiwan product service 1137 Appendix E Notices 1139 Trademarks 1140 Important notes 1140 Recycling ...

Страница 6: ...iv Lenovo System x3650 M4 HD Installation and Service Guide ...

Страница 7: ...en Ennen kuin asennat tämän tuotteen lue turvaohjeet kohdasta Safety Information Avant d installer ce produit lisez les consignes de sécurité Vor der Installation dieses Produkts die Sicherheitshinweise lesen Prima di installare questo prodotto leggere le Informazioni sulla Sicurezza Les sikkerhetsinformasjonen Safety Information før du installerer dette produktet Antes de instalar este produto le...

Страница 8: ... caution statement are in the Safety Information document under Statement 1 Be sure to read all caution and danger statements in this documentation before you perform the procedures Read any additional safety information that comes with your system or optional device before you install the device Statement 1 DANGER Electrical current from power telephone and communication cables is hazardous To av...

Страница 9: ... the lithium battery use only Part Number 33F8354 or an equivalent type battery recommended by the manufacturer If your system has a module containing a lithium battery replace it only with the same module type made by the same manufacturer The battery contains lithium and can explode if not properly used handled or disposed of Do not Throw or immerse into water Heat to more than 100 C 212 F Repai...

Страница 10: ...eil A Laser de Classe 1 Statement 4 CAUTION Use safe practices when lifting 18 kg 39 7 lb 32 kg 70 5 lb 55 kg 121 2 lb Statement 5 CAUTION The power control button on the device and the power switch on the power supply do not turn off the electrical current supplied to the device The device also might have more than one power cord To remove all electrical current from the device ensure that all po...

Страница 11: ...upply or any part that has the following label attached Hazardous voltage current and energy levels are present inside any component that has this label attached There are no serviceable parts inside these components If you suspect a problem with one of these parts contact a service technician Statement 12 CAUTION The following label indicates a hot surface nearby Statement 26 CAUTION Do not place...

Страница 12: ... the leveling pads on the rack cabinet Always install stabilizer brackets on the rack cabinet Always install servers and optional devices starting from the bottom of the rack cabinet Always install the heaviest devices in the bottom of the rack cabinet x Lenovo System x3650 M4 HD Installation and Service Guide ...

Страница 13: ...h the server The server contains X Architecture technologies which help increase performance and reliability For more information see What your server offers on page 12 and Reliability availability and serviceability on page 15 You can obtain up to date information about the server and other Lenovo server products at http shop lenovo com us en systems At http www ibm com support mysupport you can ...

Страница 14: ...above each bay If firmware and documentation updates are available you can download them from the Lenovo website The server might have features that are not described in the documentation that comes with the server and the documentation might be updated occasionally to include information about those features or technical updates might be available to provide additional information that is not inc...

Страница 15: ...erGuide Setup and Installation CD to help you configure the hardware install device drivers and install the operating system For a list of supported optional devices for the server see http www lenovo com serverproven The Lenovo Documentation CD The Lenovo Documentation CD contains documentation for the server in Portable Document Format PDF and includes the Lenovo Documentation Browser to help yo...

Страница 16: ...en you select a document a description of the document is displayed under Topic Description To select more than one document press and hold the Ctrl key while you select the documents Click View to view the selected document or documents in Acrobat Reader or xpdf If you selected more than one document all the selected documents are opened in Acrobat Reader or xpdf To search all the documents type ...

Страница 17: ...the server model additional documentation might be included on the Lenovo Documentation CD The ToolsCenter for System x and BladeCenter is an online information center that contains information about tools for updating managing and deploying firmware device drivers and operating systems The ToolsCenter for System x and BladeCenter is at http publib boulder ibm com infocenter toolsctr v1r0 The serv...

Страница 18: ...peed up to 8 0 GT per second Notes Use the Setup utility to determine the type and speed of the microprocessors in the server For a list of supported microprocessors see http www lenovo com serverproven Memory Minimum 2 GB Maximum 768 GB 64 GB using unbuffered DIMMs UDIMMs 384 GB using registered DIMMs RDIMMs 768 GB using load reduction DIMMs LRDIMMs Type PC3 8500 DDR3 1066 PC3 10600 DDR3 1333 PC3...

Страница 19: ...Slot 1 PCI Express 3 0 x8 full height full length Slot 2 PCI Express 3 0 x8 full height half length Slot 3 PCI Express 3 0 x8 full height half length Type 2 Slot 1 PCI Express 3 0 x16 full height full length Slot 2 PCI Express 3 0 x8 full height half length Slot 3 not available Type 3 Slot 1 PCI X full height full length Slot 2 PCI X full height half length Slot 3 PCI Express 3 0 x16 full height h...

Страница 20: ... One System Management RJ 45 on the rear to connect to a systems management network This system management connector is dedicated to the IMM2 functions One serial port Two VGA ports One is on the rear the other one is optional when the video and USB breakout cable is installed Light path diagnostics panel Video controller integrated into the IMM2 Matrox G200eR core two analog ports one front and o...

Страница 21: ...5 Maximum dew point 24 C 75 F Maximum rate of temperature change Hard disk drives 20 C hr 68 F hr Environment Server off Temperature 5 C to 45 C 41 F to 113 F Relative humidity 8 to 85 Maximum dew point 27 C 80 6 F Storage non operating Temperature 1 C to 60 C 33 8 F to 140 0 F Maximum altitude 3 050 m 10 000 ft Relative humidity 5 to 80 Maximum dew point 29 C 84 2 F Shipment non operating Tempera...

Страница 22: ...in bels for a random sample of system Table 1 Power supply configurations One or two 550 watt power supplies One 750 watt power supply Two 750 watt power supplies One 900 watt power supply Two 900 watt power supplies Video adapters Not supported Not supported Quadro K600 or K2000 Two Quadro K600 or K2000 Not supported Quadro K600 or K2000 Two Quadro K600 or K2000 Microprocessor Support up to 95 wa...

Страница 23: ...d 2013 Internal external power supply efficiency http www plugloadsolutions com psu_reports IBM_FSA011_550W_SO 301_Report pdf http www plugloadsolutions com psu_reports IBM_7001676 XXXX_550W_SO 458_Report pdf http www plugloadsolutions com psu_reports IBM_7001605 XXXX_750W_SO 258_Report pdf http www plugloadsolutions com psu_reports SO 299_IBM_DPS 750AB 1_750W_Report pdf http www plugloadsolutions...

Страница 24: ...ing a rich set of diagnostic tests of the major components of the server DSA creates a DSA log which is a chronologically ordered merge of the system event log as the IPMI event log the integrated management module IMM event log as the ASM event log and the operating system event logs You can send the DSA log as a file to Lenovo Support or view the information as a text file or HTML file Two editi...

Страница 25: ...ent Interface IPMI version 2 0 Simple Network Management Protocol SNMP version 3 0 Common Information Model CIM Web browser Some of the features that are unique to the IMM are enhanced performance higher resolution remote video expanded security options and Feature on Demand enablement for hardware and firmware options For additional information see Using the integrated management module on page 1...

Страница 26: ...n installed If a problem occurs with the primary Ethernet connection and the optional Ethernet adapter is installed on the server all Ethernet traffic that is associated with the primary connection is automatically switched to the optional redundant Ethernet adapter connection If the applicable device drivers are installed this switching occurs without data loss and without user intervention Redun...

Страница 27: ...that is stored in the server the availability of the server when you need it and the ease with which you can diagnose and correct problems Your server has the following RAS features 3 year parts and 3 year labor limited warranty Machine Type 5460 24 hour support center Automatic error retry and recovery Automatic restart on nonmaskable interrupt NMI Automatic restart after a power failure Backup b...

Страница 28: ...le error or multi bit error by the Unified Extensible Firmware Interface UEFI Solid state drives Standby voltage for system management features and monitoring Startup boot from LAN through remote initial program load RIPL or dynamic host configuration protocol boot protocol DHCP BOOTP System auto configuring from the configuration menu System error logging POST and IMM Systems management monitorin...

Страница 29: ...pdating installed plug ins to add new features and functions to the base capabilities Managing the life cycles of virtual resources For more information about Systems Director see the documentation on the Systems Director DVD that comes with the server the Systems Director Information Center at http pic dhe ibm com infocenter director pubs index jsp topic 2Fcom ibm director main helps doc 2Ffqm0_m...

Страница 30: ...flashing it indicates that the drive is in use Hard disk drive status LEDs This LED is used on hot swap hard disk drives When this LED is lit it indicates that the drive has failed If an optional ServeRAID controller is installed in the server when this LED is flashing slowly one flash per second it indicates that the drive is being rebuilt When the LED is flashing rapidly three flashes per second...

Страница 31: ...onnector Captive screws USB ports 2 Video connector blue Figure 8 Video and USB breakout cable Operator information panel The following illustration shows the controls and LEDs on the operator information panel 1 2 3 4 Ethernet activity LEDs Check log LED Locator button locator LED Power control button power on LED Ethernet icon System error LED Reset button Figure 9 Operator information panel Pow...

Страница 32: ... system board is also lit to help isolate the error This LED is controlled by the IMM Notes 1 Depending on the type of operator information panel installed in your server the Reset button is on the operator information panel or the light path diagnostics panel 2 You do not have to pull out the operator information panel to obtain more information if there s no release latch existed in your server ...

Страница 33: ...rk traffic from the production network You can use the Setup utility to configure the server to use a dedicated systems management network or a shared network Ethernet connectors Use either of these connectors to connect the server to a network When you enable shared Ethernet for IMM2 in the Setup utility you can access the IMM2 using either the Ethernet 1 or the system management Ethernet default...

Страница 34: ...supply error LED is lit it indicates that the power supply has failed Note Power supply 1 is the default primary power supply If power supply 1 fails you must replace the power supply immediately Power on LED When this LED is lit and not flashing it indicates that the server is turned on The states of the power on LED are as follows Off Power is not present or the power supply or the LED itself ha...

Страница 35: ...minutes This is normal operation while the system loads Turning off the server Use this information for details about turning off the server When you turn off the server and leave it connected to power the server can respond to requests to the service processor such as a remote request to turn on the server While the server remains connected to power one or more fans might continue to run To remov...

Страница 36: ...ver The server can be turned off by Wake on LAN feature with the following limitation Note When you install any PCI adapter the power cords must be disconnected from the power source before you remove the PCI Express riser card assembly and the PCI X riser card assembly Otherwise the Wake on LAN feature might not work The integrated management module II IMM2 can turn off the server as an automatic...

Страница 37: ...that the server is working correctly Start the server and make sure that the operating system starts if an operating system is installed or that a 19990305 error code is displayed indicating that an operating system was not found but the server is otherwise working correctly If the server is not working correctly see Running the DSA Preboot diagnostic programs on page 139 for information about how...

Страница 38: ...diagnostic data to Lenovo Standard upload http www ibm com de support ecurep send_http html Standard upload with the system serial number http www ecurep ibm com app upload_hw Secure upload http www ibm com de support ecurep send_http html secure Secure upload with the system serial number https www ecurep ibm com app upload_hw Server components The following illustration shows the major component...

Страница 39: ...sh power module Microprocessor installation tool 1 8 inch SSD backplane assembly Power paddle card Dual port network adapter Figure 13 Server components Blue on a component indicates touch points where you can grip the component to remove it from or install it in the server open or close a latch and so on Orange on a component or an orange label on or near a component indicates that the component ...

Страница 40: ...SB hypervisor connector Power signal connector 2nd power supply to system board Power supply connector 2nd power supply to system board Microprocessor 2 Fan 4 Fan 3 Fan 2 Fan 1 SAS SATA backplane configuration connector 1 Microprocessor 1 DIMM connectors System battery SAS 0 SAS 1 SAS SATA backplane power connector 1 SAS SATA backplane configuration connector 2 Operator information panel connector...

Страница 41: ... any switch settings or move any jumpers turn off the server then disconnect all power cords and external cables Review the information in Safety on page v Installation guidelines on page 34 Handling static sensitive devices on page 36 and Turning off the server on page 23 2 Any system board switch or jumper block that is not shown in the illustrations in this document are reserved 3 If there is a...

Страница 42: ... 1 and 2 Normal default Loads the primary server firmware ROM page Pins 2 and 3 Loads the secondary backup server firmware ROM page JP20 System TPM physical presence jumper Pins 1 and 2 Normal default Pins 2 and 3 Indicates a physical presence to the system TPM 1 If no jumper is present the server responds as if the pins are set to the default 2 Changing the position of the UEFI boot backup jumper...

Страница 43: ...of this switch does not affect the administrator password check if an administrator password is set See Passwords on page 107 for additional information about passwords The following table describes the functions of the button on the system board Table 5 Button on the server Button name Function Force NMI button This button is on the rear of the server Press this button to force a nonmaskable inte...

Страница 44: ... error LED Fan 1 error LED Microprocessor 1 error LED System board error LED DIMM 19 24 error LEDs under the latches DIMM 1 6 error LEDs under the latches DIMM 7 18 error LEDs under the latches Figure 17 System board LEDs System board optional device connectors The following illustration shows the connectors on the system board for the optional devices 32 Lenovo System x3650 M4 HD Installation and...

Страница 45: ...ws the connectors on the PCI riser card for user installable PCI adapters 00 00000 00000 00000 000000 000000 000000 000000 00000 00000 00000 0000000 0000000 0000000 0000000 0000000 00 0 PCI riser card assembly in long position Adapter Adapter connectors PCI riser card assembly in short position Adapter Adapter connectors Full length adapter bracket Full length adapter bracket Figure 19 PCI riser c...

Страница 46: ...re that the devices that you are installing are supported For a list of supported optional devices for the server see http www lenovo com serverproven When you install your new server take the opportunity to download and apply the most recent firmware updates This step will help to ensure that any known issues are addressed and that your server is ready to function at maximum levels of performance...

Страница 47: ...erver open or close a latch and so on Orange on a component or an orange label on or near a component indicates that the component can be hot swapped which means that if the server and operating system support hot swap capability you can remove or install the component while the server is running Orange can also indicate touch points on hot swap components See the instructions for removing or inst...

Страница 48: ...s that could fall into the server as you lean over it Avoid dropping any metallic objects such as paper clips hairpins and screws into the server Handling static sensitive devices Use this information to handle static sensitive devices Attention Static electricity can damage the server and other electronic devices To avoid damage keep static sensitive devices in their static protective packages un...

Страница 49: ...d slide the cover toward the rear of the server until the cover has disengaged from the chassis Step 5 Lift the server cover off the server and set it aside Attention For proper cooling and airflow replace the server cover before you turn on the server Removing a PCI riser card assembly Use this information to remove a PIC riser card assembly The server comes with one riser card assembly with opti...

Страница 50: ...devices you must first remove the air baffle to access certain components or connectors on the system board The following illustration shows how to remove the air baffle To remove the air baffle complete the following steps Step 1 Read the safety information that begins on page Safety on page v and Installation guidelines on page 34 Step 2 Turn off the server and peripheral devices and disconnect ...

Страница 51: ...ore you turn on the server Operating the server with the air baffle removed might damage server components Stretching a PCI riser card assembly Use this information to stretch a PCI riser card assembly Note It is not necessary to capture adaptor card with the full length adaptor bracket when installing half length adaptor cards If you are installing a full length adapter in the upper riser card PC...

Страница 52: ...ull length adapter in the upper riser card PCI slot and will replace it with a shorter adapter or no adapter you must shrink the full length PCI riser card assembly To shrink the full length PCI riser card assembly complete the following steps Step 1 Rotate the thumb screw which is far from the PCI slot end counterclockwise and shorten the PCI riser card assembly 2 1 Figure 25 PCI riser card assem...

Страница 53: ...ress adapter slot cover in the event that you later remove the device For a complete list of supported optional devices for the server see http www lenovo com serverproven Drive IDs The drive ID that is assigned to each drive is printed on the front or rear of the server The following illustrations show the locations of the IDs of the drives The ID numbers and the drive bay numbers are the same 2 ...

Страница 54: ...4 Step 2 Remove the filler panel from the empty drive bay Keep the filler panel in a safe place Step 3 Touch the static protective package that contains the drive to any unpainted metal surface on the server then remove the drive from the package and place it on a static protective surface Step 4 Install a 2 5 inch hot swap drive a Make sure that the tray handle is in the open unlocked position b ...

Страница 55: ... If you have other devices to install or remove do so now Otherwise go to Completing the installation on page 94 Installing a memory module The following notes describe the types of DIMMs that the server supports and other information that you must consider when you install DIMMs When you install or remove DIMMs the server configuration information changes When you restart the server the system di...

Страница 56: ...module data bus L Load Reduction DIMM LRDIMM R Registered DIMM RDIMM U Unbuffered DIMM with no ECC x64 bit primary data bus aa is the CAS latency in clocks at maximum operating frequency bb is the JEDEC SPD Revision Encoding and Additions level cc is the reference design file for the design of the DIMM d is the revision number of the reference design of the DIMM Note To determine the type of a DIM...

Страница 57: ...available for the server are 2 GB 4 GB 8 GB and 16 GB The server supports a minimum of 2 GB and a maximum of 384 GB of system memory using RDIMMs The LRDIMM option that is available for the server is 32 GB The server supports a minimum of 32 GB and a maximum of 768 GB of system memory using LRDIMMs Note The amount of usable memory is reduced depending on the system configuration A certain amount o...

Страница 58: ... no matching requirements Table 7 Normal mode DIMM installation sequence Number of installed microprocessor DIMM connector population sequence One microprocessor installed 1 4 9 12 2 5 8 11 3 6 7 10 Two microprocessors installed 1 13 4 16 9 21 12 24 2 14 5 17 8 20 11 23 3 15 6 18 7 19 10 22 Memory mirrored channel Memory mirrored channel mode replicates and stores data on two pairs of DIMMs within...

Страница 59: ...y channel Figure 32 Connectors on each memory channel The following table shows the installation sequence for memory mirrored channel mode Table 8 Memory mirrored channel mode DIMM population sequence Number of DIMMs Number of installed microprocessor DIMM connector First pair of DIMMs 1 1 4 Second pair of DIMMs 1 9 12 Third pair of DIMMs 1 2 5 Fourth pair of DIMMs 1 8 11 Fifth pair of DIMMs 1 3 6...

Страница 60: ...nnector First pair of DIMMs 1 1 2 Second pair of DIMMs 1 4 5 Third pair of DIMMs 1 8 9 Fourth pair of DIMMs 1 11 12 Fifth pair of DIMMs 1 7 10 Sixth pair of DIMMs 1 3 6 Seventh pair of DIMMs 2 13 14 Eighth pair of DIMMs 2 16 17 Ninth pair of DIMMs 2 20 21 Tenth pair of DIMMs 2 23 24 Eleventh pair of DIMMs 2 19 22 Twelfth pair of DIMMs 2 15 18 Note DIMM connectors 3 6 7 10 15 18 19 and 22 are not u...

Страница 61: ...lot align correctly with the alignment tab Step 9 Insert the DIMM into the connector by aligning the edges of the DIMM with the slots at the ends of the DIMM connector see System board optional device connectors on page 32 for the locations of the DIMM connectors Step 10 Firmly press the DIMM straight down into the connector by applying pressure on both ends of the DIMM simultaneously The retainin...

Страница 62: ...he active power manager active power management event signal will be enabled by the system board logic The server provides two PCI riser card slots on the system board If you want to install a PCI Express or PCI X adapter you must order the PCI riser card option If you are installing a ServeRAID M5110 or ServeRAID M5120 adapter it can only be installed in PCI slot 1 2 4 or 5 The following table sh...

Страница 63: ...se 00 0000 0000 0000 0000 0000 0000 0000000 0000000 0000000 0000000 PCI riser card assembly Full length adapter bracket Figure 36 Full length adapter bracket removal b Riser card assembly 2 if the adapter is a full length adapter for the upper expansion slot in the riser card the full length adapter bracket is on the cage by default Step 8 Connect any required cables to the adapter see Internal ca...

Страница 64: ...age 224 Step 5 Follow the cabling instructions if any come with the adapter Route the adapter cables before you install the adapter Attention When you route cables do not block any connectors or the ventilated space around any of the fans Make sure that cables are not routed on top of components under the rear two hard disk drive kit Make sure that cables are not pinched by the server components S...

Страница 65: ... and disconnect all power cords Step 3 Remove the cover see Removing the cover on page 37 Step 4 Connect the cable to the ServeRAID adapter memory module ServeRAID memory module Flash power module cable Figure 38 Cable installation Step 5 Align the memory module with the retention pins Install the memory module into the system board Connector Rentention pins ServeRAID memory module Figure 39 Serve...

Страница 66: ...e Important The battery must recharge for at least 6 hours under normal operating conditions To protect your data the ServeRAID controller firmware changes the write policy to write through until the battery unit is sufficiently charged When the battery unit is charged the ServeRAID controller firmware changes the write policy to write back For brevity in this documentation the Intelligent Battery...

Страница 67: ...nched and does not cover any connectors or obstruct any components on the system board Step 7 Install the battery or flash power module on top of the air baffle a Align the battery or flash power module cable connector with the slot on the holder Place the battery or flash power module into the holder and make sure that the holder engages the battery or flash power module securely Chapter 2 Instal...

Страница 68: ...batteries or flash power modules that you install b Connect the other end of the cable to the battery or flash power module 00000 00000 00000 00000 00000 00000 Flash power module cable ServeRAID memory module Flash power module Figure 43 Battery or flash power module cable installation Note Make sure the battery or flash power module is seated properly 56 Lenovo System x3650 M4 HD Installation and...

Страница 69: ...ort network adapter Option part number FRU part number Qlogic dual port 10GbE SFP Embedded VFA 90Y6454 90Y5099 Dual port FDR embedded adapter 00D4143 00J6248 The following notes describe the types of adapters that the server supports and other information that you must consider when you install an adapter To configure network adapters complete the following steps 1 From the Setup utility main menu...

Страница 70: ...to the Lenovo website The actual procedure might vary slightly from what is described in this document Port 0 on the Emulex Dual Port 10GbE SFP Embedded VFA III can be configured as shared system management When the server is in standby mode both ports on the Emulex Dual Port 10GbE SFP Embedded VFA III function at 100M connection speed with Wake on LAN feature The Emulex Dual Port 10GbE SFP Embedd...

Страница 71: ...that contains the new adapter to any unpainted metal surface on the server Then remove the adapter from the package Step 7 Align the adapter so that the port connectors on the adapter line up with the pin and thumbscrew on the chassis then align the connector of the adapter with the adapter connector on the system board Chapter 2 Installing optional devices 59 ...

Страница 72: ...tention brackets engage the adapter Make sure the adapter is securely seated on the connector on the system board Attention Make sure the port connectors on the adapter are aligned properly with the chassis on the rear of the server An incorrectly seated adapter might cause damage to the system board or the adapter Step 9 Fasten the thumbscrew on the rear side of the chassis 60 Lenovo System x3650...

Страница 73: ...hen you install a power supply Before you install an additional power supply or replace a power supply with one of a different wattage you may use the Power Configurator utility to determine current system power consumption For more information and to download the utility go to http www ibm com systems bladecenter resources powerconfig html The server comes with one hot swap 12 volt output power s...

Страница 74: ...vice also might have more than one power cord To remove all electrical current from the device ensure that all power cords are disconnected from the power source 1 2 Statement 8 CAUTION Never remove the cover on a power supply or any part that has the following label attached Hazardous voltage current and energy levels are present inside any component that has this label attached There are no serv...

Страница 75: ...forward into the power supply bay until it clicks Make sure that the power supply connects firmly into the power supply connector Attention Do not install power supplies of different watt in the server Step 5 Route the power cord through the handle and cable tie if any so that it does not accidentally become unplugged Step 6 Connect the power cord for the new power supply to the power cord connect...

Страница 76: ...pports and other information that you must consider when you install a power supply Before you install an additional power supply or replace a power supply with one of a different wattage you may use the Power Configurator utility to determine current system power consumption For more information and to download the utility go to http www ibm com systems bladecenter resources powerconfig html The ...

Страница 77: ... 29 CAUTION This equipment is designed to permit the connection of the earthed conductor of the dc supply circuit to the earthing conductor at the equipment This equipment is designed to permit the connection of the earthed conductor of the dc supply circuit to the earthing conductor at the equipment If this connection is made all of the following conditions must be met This equipment shall be con...

Страница 78: ...to be attached to this product 2 Attach signal cables to the product 3 Attach power cords to the product For ac systems use appliance inlets For dc systems ensure correct polarity of 48 V dc connections RTN is and 48 V dc is Earth ground should use a two hole lug for safety 4 Attach signal cables to other devices 5 Connect power cords to their sources 6 Turn ON all the power sources 1 Turn OFF all...

Страница 79: ...nt Be sure to read the multilingual safety instructions on the CD that comes with the server before you use the product Installing a hot swap dc power supply Use this information to install a hot swap dc power supply Attention Only trained service personnel other than Lenovo service technicians are authorized to install and remove the 48 volt dc power supply and make the connections to and disconn...

Страница 80: ...ower supply connector Step 7 Route the power cord through the handle and cable tie if any so that it does not accidentally become unplugged Step 8 Connect the other ends of the dc power cable to the dc power source Cut the wires to the correct length but do not cut them shorter than 150 mm 6 inch If the power source requires ring terminals you must use a crimping tool to install the ring terminals...

Страница 81: ...edundant power information label that comes with this option on the server cover near the power supplies Figure 54 Redundant power information label Installing a USB embedded hypervisor flash device Use this information to install a USB embedded hypervisor flash device To install a USB hypervisor flash device complete the following steps Step 1 Read the safety information that begins on Safety on ...

Страница 82: ...her devices to install or remove do so now Otherwise go to Completing the installation on page 94 Installing the front video and USB breakout cable Use this information to install the front video and USB breakout cable To install the front video and USB breakout cable complete the following steps Step 1 Read the safety information that begins on Safety on page v and Installation guidelines on page...

Страница 83: ...board Any damage to the microprocessor sockets may require replacing the system board Be extremely careful the microprocessor socket contacts are very fragile Do not touch the microprocessor socket contacts Contaminants on the microprocessor contacts or microprocessor socket contacts such as oil from your skin can cause connection failures between the contacts and the socket Do not allow the therm...

Страница 84: ...ing levels within the same server model you do not have to install the microprocessor with lowest stepping level and features in microprocessor socket 1 Both microprocessor voltage regulator modules are integrated on the system board Read the documentation that comes with the microprocessor to determine whether you have to update the server firmware To download the latest level of server firmware ...

Страница 85: ...nes on page 34 Step 2 Turn off the server and peripheral devices and disconnect the power cords and all external cables Attention When you handle static sensitive devices take precautions to avoid damage from static electricity For details about handling these devices see Handling static sensitive devices on page 36 Step 3 Remove the cover see Removing the cover on page 37 Step 4 Remove the air ba...

Страница 86: ... and the microprocessor socket Step 7 Install the microprocessor in the microprocessor socket a Open the packaging that contains the new microprocessor installation tool assembly and carefully remove the installation tool assembly from the package Note Do not touch the microprocessor contacts Contaminants on the microprocessor contacts such as oil from your skin can cause connection failures betwe...

Страница 87: ...tion tool If using Installation Tool A twist the handle on the microprocessor tool assembly counterclockwise to the open position to insert the microprocessor into the socket and lift the installation tool out of the socket If using Installation Tool B twist the handle of the installation tool assembly counterclockwise until the microprocessor is inserted into the socket and lift the installation ...

Страница 88: ...he socket before you try to close the microprocessor retainer Do not touch the thermal material on the bottom of the heat sink or on top of the microprocessor Touching the thermal material will contaminate it Step 8 Remove the microprocessor socket cover tape or label from the surface of the microprocessor socket if one is present Store the socket cover in a safe place 76 Lenovo System x3650 M4 HD...

Страница 89: ...ocket levers and retainer engagement a Close the microprocessor retainer on the microprocessor socket b Identify which release lever is labeled as the first release lever to close and close it c Close the second release lever on the microprocessor socket Attention If you are installing a new heat sink do not set down the heat sink after you remove the plastic cover Do not touch the thermal grease ...

Страница 90: ...icroprocessor The heat sink is keyed to assist with proper alignment Figure 67 Heat sink installation c Align and place the heat sink on top of the microprocessor in the retention bracket thermal material side down d Press firmly on the heat sink e Rotate the heat sink retention module release lever to the closed position and hook it underneath the lock tab If you have other devices to install or ...

Страница 91: ...mal grease on the microprocessor and heat sink complete the following steps Step 1 Place the heat sink on a clean work surface Step 2 Remove the cleaning pad from its package and unfold it completely Step 3 Use the cleaning pad to wipe the thermal grease from the bottom of the heat sink Note Make sure that all of the thermal grease is removed Step 4 Use a clean area of the cleaning pad to wipe the...

Страница 92: ...e 8x2 5 inch hot swap HDD assembly kit with expander contains the following components One expander One backplane connection cable Two screws One power cable One configuration cable Eight 2 5 inch HDD fillers Note The option including structural parts and Tier 1 parts To install the 8x2 5 inch hot swap HDD assembly kit with expander complete the following steps Step 1 Read the safety information t...

Страница 93: ...e backplane cage b Insert the expander tabs into slots on the bottom of the backplane cage and push the expander forward into the retention latch on top of the backplane cage until the expander is locked in place Step 5 Connect the backplane connection cable power cable and the configuration cable Chapter 2 Installing optional devices 81 ...

Страница 94: ...0 0000000000 0000000000 0000000000 Mini SAS cable Power cable Configuration cable Backplane connection cable SAS 0 SAS 1 Power cable Configuration cable Port 1 Port 0 Figure 71 Cables connection 82 Lenovo System x3650 M4 HD Installation and Service Guide ...

Страница 95: ...s cable connection Step 6 Remove the two 4 drive filler panels from the right side 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 4 drive filler panel Filler panel Figure 73 Filler panels removal Step 7 Install the hard disk drives if any see Installing a hot swap drive on page 42 Step 8 Install the 2 5 inch HDD fillers into empty drives Chapter 2 Installing optional devices 83 ...

Страница 96: ...x2 5 inch hot swap HDD assembly kit contains the following components One hot swap HDD backplane Two mini SAS cables One power cable One configuration cable Eight 2 5 inch HDD fillers Note The option including structural parts and Tier 1 parts To install the 8x2 5 inch hot swap HDD assembly kit complete the following steps Step 1 Read the safety information that begins on Safety on page v and Inst...

Страница 97: ... of the backplane cage b Insert the backplane tabs into slots on the bottom of the backplane cage and push the backplane forward into the retention latch on top of the backplane cage until the backplane is locked in place Step 5 Connect the mini SAS cables power cable and the configuration cable Chapter 2 Installing optional devices 85 ...

Страница 98: ... 000000000 000000000 Mini SAS cable Power cable Configuration cable Backplane connection cable SAS 0 SAS 1 Power cable Configuration cable Port 0 Port 1 Port 1 Port 0 Port 0 Port 1 Figure 75 Cables connection 86 Lenovo System x3650 M4 HD Installation and Service Guide ...

Страница 99: ...planes cable connection Step 6 Remove the two 4 drive filler panels from the right side 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 4 drive filler panel Filler panel Figure 77 Filler panels removal Step 7 Install the hard disk drives if any see Installing a hot swap drive on page 42 Step 8 Install the 2 5 inch HDD fillers into empty drives Chapter 2 Installing optional devices 87 ...

Страница 100: ...iguration cable One backplane power Y cable One backplane configuration Y cable Four mini SAS cables 820 mm Two mini SAS cables 925 mm Eight 2 5 inch HDD fillers Note The option including structural parts and Tier 1 parts To install the 3x8 2 5 inch hot swap HDD assembly kit complete the following steps Step 1 Read the safety information that begins on Safety on page v and Installation guidelines ...

Страница 101: ...e outside of the server then grasp the backplane and remove it from the package Step 8 Install the backplane in the slot you removed the expander earlier Backplanes Retention latchs Figure 80 Backplane installation a Align the tabs on the bottom of the backplane with the slots on the bottom of the backplane cage Chapter 2 Installing optional devices 89 ...

Страница 102: ...farthest slot from the power supplies Step 10 Connect the mini SAS cables power cables and the configuration cables 0000000000 0000000000 0000000000 0000000000 0000000000 0000000000 0000000000 0000000000 Mini SAS cable Power cable Configuration cable SAS 0 SAS 1 Power cable Configuration cable Port 0 Port 1 Riser 1 Riser 2 Port 0 Port 1 Port 0 Port 1 Port 0 Port 1 Figure 81 Cables connection 90 Le...

Страница 103: ...kit To order the 16x1 8 inch SSD assembly kit contact your Lenovo sales representative or Lenovo reseller The 16x1 8 inch SSD assembly kit contains the following components Two 1 8 inch solid state drive backplane assemblies One power cable One configuration cable Four mini SAS cables 820 mm To install the 16x1 8 inch SSD assembly kit in the server complete the following steps Step 1 Read the safe...

Страница 104: ...h backplane assemblies 0000 0000 0000 0000 0000 0000 0000 0000 0000 1 8 inch filler panel 8x1 8 inch drive backplane assembly Figure 84 1 8 inch backplane assembly installation Step 6 Connect the following cables in the order listed Configuration cable Mini SAS cables Power cable 92 Lenovo System x3650 M4 HD Installation and Service Guide ...

Страница 105: ...00 0000000000 0000000000 Power cable Configuration cable Backplane connection cable SAS 0 SAS 1 Power cable Configuration cable Mini SAS cable Port 0 Port 1 Riser 1 Riser 2 Port 0 Port 1 Port 0 Port 1 Figure 85 Cables connection Chapter 2 Installing optional devices 93 ...

Страница 106: ...u removed the air baffle reinstall it see Replacing the air baffle on page 94 Step 2 If you removed the server cover replace it see Replacing the cover on page 96 Step 3 Install the server in the rack cabinet see the Rack Installation Instructions that come with the server for instructions Step 4 Reconnect the cables and power cords see Connecting the external cables on page 97 Step 5 Update the s...

Страница 107: ... the air baffle pins with the baffle pin holes on both sides of the chassis then lower the air baffle into the server Press the air baffle down until it is securely seated Note Close the retaining clip on each end of the DIMM connector before installing the air baffle for proper cooling 0 0 0 0 0 0 0 000 000 00 00 000000 000000 000000 000000 0000 0000 0000 0000 0000 0 0 000000 000000 000000 000000...

Страница 108: ...00 000000 000000 000 000 000 PCI riser card assembly 2 PCI riser card assembly 1 Figure 88 PCI riser card assembly installation PCI riser card assembly 1 Carefully fit the two alignment slots on the side of the assembly onto the two alignment brackets in the side of the chassis PCI riser card assembly 2 Carefully align the bottom edge the contact edge of the PCI riser card assembly with the PCI ri...

Страница 109: ...e server Step 4 Make sure that the cover correctly engages all the inset tabs on the server Step 5 Press down the blue latch on the top in the center of the front of the server of the cover 0 0 0 0 0 0 0 000000000000 000000000000 000000000000 000000000000 000000000000 000000000000 000000000000 Cover release latch 1 2 Figure 89 Cover installation Step 6 Slide the server all the way into the rack un...

Страница 110: ...the operating system for additional cabling instructions Updating the server configuration When you start the server for the first time after you add or remove a device you might receive a message that the configuration has changed The Setup utility starts automatically so that you can save the new configuration settings Some optional devices have device drivers that you must install For informati...

Страница 111: ...ler to acquire and apply UpdateXpress System Packs and individual firmware and device driver updates For additional information and to download the UpdateXpress System Pack Installer go to the ToolsCenter for System x and BladeCenter at https support lenovo com us en documents LNVO CENTER and click UpdateXpress System Pack Installer When you click an update an information page is displayed includi...

Страница 112: ...ates that enable replication of settings to many servers and automation that reduces hands on time and user errors Wizards and other default settings enable customization capabilities The low touch set once and walk away feature reduces the hands on server setup time from days to minutes particularly for larger deployments For information about this tool see http www ibm com support entry portal d...

Страница 113: ...program online or out of band to modify UEFI settings from the command line without the need to restart the server to run the Setup utility For more information about using this program see Advanced Settings Utility program on page 115 Configuring RAID arrays For information about configuring RAID arrays see Configuring RAID arrays on page 115 The following table lists the different server configu...

Страница 114: ...tures An easy to use interface Diskette free setup and configuration programs that are based on detected hardware Device drivers that are provided for the server model and detected hardware Operating system partition size and file system type that are selectable during setup The ServerGuide program performs the following tasks Sets system date and time Detects the RAID adapter or controller and ru...

Страница 115: ... to complete the installation Installing your operating system without using ServerGuide Use this information to install the operating system on the server without using ServerGuide If you have already configured the server hardware and you are not using the ServerGuide program to install your operating system you can download operating system installation instructions for the server from http www...

Страница 116: ...nnot change settings directly in the system summary Product Data Select this choice to view the system board identifier the revision level or issue date of the firmware the integrated management module and diagnostics code and the version and date This choice is on the full Setup utility menu only System Settings Select this choice to view or change the server component settings Adapters and UEFI ...

Страница 117: ...to enable or disable legacy boot in BBS manner The default is Enable System Security Select this choice to view or configure Trusted Platform Module TPM support Integrated Management Module Select this choice to view or change the settings for the integrated management module Power Restore Policy Select this choice to set the mode of operation after the power lost Commands on USB Interface Select ...

Страница 118: ... the startup options take effect when you start the server The startup sequence specifies the order in which the server checks devices to find a boot record The server starts from the first boot record that it finds If the server has Wake on LAN hardware and software and the operating system supports Wake on LAN functions you can specify a startup sequence for the Wake on LAN functions For example...

Страница 119: ... the full Setup utility menu If an administrator password is set the full Setup utility menu is available only if you type the administrator password at the password prompt See Administrator password on page 109 for more information Clear Administrator Password Select this choice to clear an administrator password See Administrator password on page 109 for more information Save Settings Select thi...

Страница 120: ...that authority Power on password If a power on password is set when you turn on the server you must type the power on password to complete the system startup You can use any combination of 6 20 printable ASCII characters for the password When a power on password is set you can enable the Unattended Start mode in which the keyboard and mouse remain locked but the operating system can start You can ...

Страница 121: ...ssword override You can then start the Setup utility and reset the power on password You do not have to return the switch to the previous position The power on password override switch does not affect the administrator password Administrator password If an administrator password is set you must type the administrator password for access to the full Setup utility menu You can use any combination of...

Страница 122: ...ess System Pack Installer go to the ToolsCenter for System x and BladeCenter at http publib boulder ibm com infocenter toolsctr v1r0 and click UpdateXpress System Pack Installer Using the integrated management module The integrated management module IMM is a second generation of the functions that were formerly provided by the baseboard management controller hardware It combines service processor ...

Страница 123: ...g System event log SEL user readable event log The IMM also provides the following remote server management capabilities through the ipmitool management utility program Command line interface IPMI Shell The command line interface provides direct access to server management functions through the IPMI 2 0 protocol Use the command line interface to issue commands to control the server power view syst...

Страница 124: ...rver To derive the link local address complete the following steps Step 1 Take the last 12 characters on the IMM MAC address for example 5CF3FC5EAAD0 Step 2 Separate the number into pairs of hexadecimal characters for example 5C F3 FC 5E AA D0 Step 3 Separate the first six and last six hexadecimal characters Step 4 Add FF and FE in the middle of the 12 characters for example 5C F3 FC FF FE 5E AA D...

Страница 125: ... 3 Click Log in to start the session The System Status and Health page provides a quick view of the system status Note If you boot to the operating system while in the IMM GUI and the message Booting OS or in unsupported OS is displayed under System Status System State disable Windows 2008 or 2012 firewall or type the following command in the Windows 2008 or 2012 console This might also affect blu...

Страница 126: ...ork and provide full duplex FDX capability which enables simultaneous transmission and reception of data on the network If the Ethernet ports in the server support auto negotiation the controllers detect the data transfer rate 10BASE T 100BASE TX or 1000BASE T and duplex mode full duplex or half duplex of the network and automatically operate at that rate and mode You do not have to set any jumper...

Страница 127: ...pology that is implemented in your environment there are a number of different ways to connect manageable systems to the network and to set up the Lenovo XClarity Administrator If you plan to use Lenovo XClarity Administrator to manage the server you must check for the latest applicable Lenovo XClarity Administrator updates For installing the Lenovo XClarity Administrator in VMware ESXi based and ...

Страница 128: ...am Installing updates with your management server is connected to the Internet If your management server is connected to the Internet to locate and install updates and interim fixes complete the following steps Step 1 Make sure that you have run the Discovery and Inventory collection tasks Step 2 On the Welcome page of the Systems Director web interface click View updates Step 3 Click Check for up...

Страница 129: ...d Management Module IMM Select one of the following methods to access the Integrated Management Module IMM to set the UUID Online from the target system LAN or keyboard console style KCS access Remote access to the target system LAN based Bootable media containing ASU LAN or KCS depending upon the bootable media Step 3 Copy and unpack the ASU package which also includes other required files to the...

Страница 130: ... be installed Some operating systems have the IPMI driver installed by default ASU provides the corresponding mapping layer See the Advanced Settings Utility User s Guide for more details You can download the Advanced Settings Utility User s Guide at https support lenovo com us en documents LNVO ASU Remote LAN access type the command Note When using the remote LAN access method to access IMM using...

Страница 131: ...MI Online from the target system LAN or keyboard console style KCS access Remote access to the target system LAN based Bootable media containing ASU LAN or KCS depending upon the bootable media Step 3 Copy and unpack the ASU package which also includes other required files to the server Make sure that you unpack the ASU and the required files to the same directory In addition to the application ex...

Страница 132: ...rid and password default values asu set SYSTEM_PROD_DATA SysInfoProdName m t_model asu set SYSTEM_PROD_DATA SysInfoSerialNum s n asu set SYSTEM_PROD_DATA SysEncloseAssetTag asset_tag Online KCS access unauthenticated and user restricted You do not need to specify a value for access_method when you use this access method The KCS access method uses the IPMI KCS interface This method requires that th...

Страница 133: ... imm_ip user imm_user_id password imm_password asu set SYSTEM_PROD_DATA SysEncloseAssetTag asset_tag host imm_ip user imm_user_id password imm_password Examples that do use the userid and password default values asu set SYSTEM_PROD_DATA SysInfoProdName m t_model host imm_ip asu set SYSTEM_PROD_DATA SysInfoSerialNum s n host imm_ip asu set SYSTEM_PROD_DATA SysEncloseAssetTag asset_tag host imm_ip B...

Страница 134: ...122 Lenovo System x3650 M4 HD Installation and Service Guide ...

Страница 135: ...ccurred If any hardware software or firmware was changed before the problem occurred if possible reverse those changes This might include any of the following items Hardware components Device drivers and firmware System software UEFI firmware System input power or network connections Step 2 View the light path diagnostics LEDs and event logs The server is designed for ease of diagnosis of hardware...

Страница 136: ...unning preboot diagnostics For more information about UpdateXpress System Packs see http www ibm com support entry portal docdisplay lndocid SERV XPRESS and Updating the firmware on page 99 For more information about the Bootable Media Creator see https support lenovo com us en documents LNVO BOMC Be sure to separately install any listed critical updates that have release dates that are later than...

Страница 137: ...ttp www lenovo com support Step 8 Use the troubleshooting tables See Troubleshooting by symptom on page 140 to find a solution to a problem that has identifiable symptoms A single problem might cause multiple symptoms Follow the troubleshooting procedure for the most obvious symptom If that procedure does not diagnose the problem use the procedure for another symptom if possible If the problem rem...

Страница 138: ...ard disk drive cluster two or more servers sharing external storage devices If it is part of a cluster you can run all diagnostic programs except the ones that test the storage unit that is a hard disk drive in the storage unit or the storage adapter that is attached to the storage unit The failing server might be part of a cluster if any of the following conditions is true You have identified the...

Страница 139: ... DSA reports an error follow the instructions in Appendix C DSA diagnostic test results on page 977 If DSA does not report an error but you still suspect a problem see Solving undetermined problems on page 160 Diagnostic tools The section introduces available tools to help you diagnose and solve hardware related problems Light path diagnostics Use light path diagnostics to diagnose system errors q...

Страница 140: ...ut hub and UEFI error logs Network interfaces and settings Option card driver and firmware information RAID controller configuration Service processor integrated management module status and configuration System configuration Vital product data firmware and UEFI configuration DSA Portable creates a DSA log which is a chronologically ordered merge of the system event log as the IPMI event log the i...

Страница 141: ...ot diagnostic programs on page 139 for more information on running the DSA Preboot program on the server Troubleshooting by symptom These tables list problem symptoms and actions to correct the problems See Troubleshooting by symptom on page 140 for more information Light path diagnostics Light path diagnostics is a system of LEDs on various external and internal components of the server that lead...

Страница 142: ...el 1 2 3 4 Ethernet activity LEDs Check log LED Locator button locator LED Power control button power on LED Ethernet icon System error LED Reset button Figure 93 Operator information panel 2 Remove the server cover and look inside the server for lit LEDs Certain components inside the server have LEDs that are lit to indicate the location of a problem Note You do not have to remove the server cove...

Страница 143: ... supply LEDs The following minimum configuration is required for the server to start One microprocessor in microprocessor socket 1 One 2 GB DIMM on the system board One power supply Power cord Four cooling fans One PCI riser card assembly in PCI connector 1 AC power supply LEDs Use this information to view AC power supply LEDs The following minimum configuration is required for the DC LED on the p...

Страница 144: ...s connected to a functioning power source 3 Restart the server If the error remains check the power supply LEDs 4 If the problem remains replace the power supply This is a normal condition when no ac power is present Off Off On The power supply has failed Replace the power supply Off On Off The power supply has failed Replace the power supply Off On On The power supply has failed Replace the power...

Страница 145: ...erver 2 Make sure that the power cord is connected to a functioning power source 3 Restart the server If the error remains check the power supply LEDs 4 If the problem remains replace the power supply This is a normal condition when no dc power is present Off Off On The power supply has failed Replace the power supply Off On Off The power supply has failed Replace the power supply Off On On The po...

Страница 146: ...em board IMM2 heartbeat IMM2 heartbeat boot process The following steps describe the different stages of the IMM2 heartbeat sequencing process 1 When this LED is blinking fast approximately 4Hz this indicates that the IMM2 code is in the loading process 2 When this LED goes off momentarily this indicates that the IMM2 code has loaded completely 3 When this LED goes off momentarily and then starts ...

Страница 147: ...ecent events available for analysis For more information about the system event log see Appendix A Integrated management module II IMM2 error messages on page 303 Messages are listed on the left side of the screen and details about the selected message are displayed on the right side of the screen To move from one entry to the next use the Up Arrow and Down Arrow keys Some IMM sensors cause assert...

Страница 148: ...m event log Most recent versions of the Linux operating system come with a current version of IPMItool For an overview of IPMI go to http www ibm com developerworks linux blueprints and click Using Intelligent Platform Management Interface IPMI on Lenovo Linux platforms You can view the IMM event log through the Event Log link in the integrated management module II IMM2 web interface For more info...

Страница 149: ... log is automatically cleared each time the server is restarted Step 1 Turn on the server Step 2 When the prompt F1 Setup is displayed press F1 If you have set both a power on password and an administrator password you must type the administrator password to view the event logs Step 3 To clear the IMM system event log select System Event Logs Clear System Event Log then press Enter twice POST When...

Страница 150: ...operating system you do not have to restart the server to run it It is packaged as a self extracting file that you download from the web When you run the file it self extracts to a temporary folder and performs comprehensive collection of hardware and operating system information After it runs it automatically deletes the temporary files and folder and leaves the results of the data collection and...

Страница 151: ...mory diagnostic environment you must restart the server to access the stand alone memory diagnostic environment again Step 5 Type gui to display the graphical user interface or type cmd to display the DSA interactive menu Step 6 Follow the instructions on the screen to select the diagnostic test to run If the diagnostic programs do not detect any hardware errors but the problem remains during norm...

Страница 152: ...ks and captures system hardware errors and hardware and software inventory information and reports serviceable problems directly to Lenovo Support You can also choose to collect data manually It uses minimal system resources and can be downloaded from the Lenovo website For more information and to download Electronic Service Agent go to http www 01 ibm com support esa Error messages This section p...

Страница 153: ...d disk drive problems Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved If an action step is preceded by Trained technician only that step must be performed only by a trained technician Go to the Lenovo support website at http www lenovo com support to check for technical information hints tips and new device drivers or to submit a ...

Страница 154: ...luster solutions require specific code levels or coordinated code updates If the device is part of a cluster solution verify that the latest level of code is supported for the cluster solution before you update the code Multiple hard disk drives are offline 1 Review the storage subsystem logs for indications of problems within the storage subsystem such as backplane or cable problems 2 See Problem...

Страница 155: ...hich they are listed in the Action column until the problem is solved If an action step is preceded by Trained technician only that step must be performed only by a trained technician Go to the Lenovo support website at http www lenovo com support to check for technical information hints tips and new device drivers or to submit a request for information Symptom Action A problem occurs only occasio...

Страница 156: ...ice from the hub and connect it directly to the server 3 Replace the mouse or USB device Memory problems Use this information to solve memory problems Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved If an action step is preceded by Trained technician only that step must be performed only by a trained technician Go to the Lenovo su...

Страница 157: ...blem is not the microprocessor or the DIMM connector 8 Trained technician only Replace the system board Multiple DIMMs in a channel are identified as failing Note Each time you install or remove a DIMM you must disconnect the server from the power source then wait 10 seconds before restarting the server 1 Reseat the DIMMs then restart the server 2 Remove the highest numbered DIMM of those that are...

Страница 158: ...that comes with the monitor for instructions for testing and adjusting the monitor If you cannot diagnose the problem call for service Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved If an action step is preceded by Trained technician only that step must be performed only by a trained technician Go to the Lenovo support website at...

Страница 159: ...rograms 1 Make sure that The application program is not setting a display mode that is higher than the capability of the monitor You installed the necessary device drivers for the application 2 Run video diagnostics see Running the DSA Preboot diagnostic programs on page 139 If the server passes the video diagnostics the video is good see Solving undetermined problems on page 160 Trained technicia...

Страница 160: ...on step is preceded by Trained technician only that step must be performed only by a trained technician Go to the Lenovo support website at http www lenovo com support to check for technical information hints tips and new device drivers or to submit a request for information Symptom Action Unable to wake the server using the Wake on LAN feature 1 If you are using the dual port network adapter and ...

Страница 161: ...secure 2 If the device comes with test instructions use those instructions to test the device 3 If the failing device is a SCSI device make sure that The cables for all external SCSI devices are connected correctly The last device in each SCSI chain or the end of the SCSI cable is terminated correctly Any external SCSI device is turned on You must turn on an external SCSI device before you turn on...

Страница 162: ...ower supplies in the server will cause a system error the system error LED on the front panel turns on 4 Make sure that The power cords are correctly connected to the server and to a working electrical outlet The type of memory that is installed is correct The DIMMs are fully seated The LEDs on the power supply do not indicate a problem The microprocessors are installed in the correct sequence 5 R...

Страница 163: ...lacing a microprocessor and heat sink on page 287 5 Replace the power supply if the system error LED on the operator information panel is still lit The system error LED on the light path diagnostics panel is lit and the Pwr rail C error has been recorded in the IMM event log 1 Disconnect the server power cords 2 Remove the following components if Pwr rail C error has been recorded in the IMM2 even...

Страница 164: ...ts one at a time in the order shown restarting the server each time If the Pwr rail D error has been recorded in the IMM event log again the component that you just reinstalled is defective Replace the defective component DIMMs 7 through 12 see Removing a memory module on page 214 and Installing a memory module on page 43 Fan 2 see Removing a hot swap fan on page 241 and Replacing a hot swap fan o...

Страница 165: ...nt log again trained technician only replace the system board see Removing the system board on page 296 and Replacing the system board on page 298 4 Reinstall the components one at a time in the order shown restarting the server each time If the Pwr rail F error has been recorded in the IMM event log again the component that you just reinstalled is defective Replace the defective component DIMMs 1...

Страница 166: ...ent Hard disk drive backplane assembly Hard disk drives Fan 3 see Removing a hot swap fan on page 241 and Replacing a hot swap fan on page 242 Optional PCI adaptor power cable if one is present see Removing an adapter on page 226 and Replacing an adapter on page 228 5 Follow actions in Solving power problems on page 157 if the system error LED on the light path diagnostics panel is still lit 6 Rep...

Страница 167: ...nd Replacing an adapter on page 228 PCI adapter power cable see Removing an adapter on page 226 and Replacing an adapter on page 228 5 Follow actions in Solving power problems on page 157 if the system error LED on the operator information panel is still lit 6 Replace the power supply if the system error LED on the operator information panel is still lit The server does not turn off 1 Determine wh...

Страница 168: ...ems Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved If an action step is preceded by Trained technician only that step must be performed only by a trained technician Go to the Lenovo support website at http www lenovo com support to check for technical information hints tips and new device drivers or to submit a request for inform...

Страница 169: ...t comes with the software for a description of the messages and suggested solutions to the problem 3 Contact the software vendor Universal Serial Bus USB port problems Use this information to solve Universal Serial Bus USB port problems Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved If an action step is preceded by Trained techni...

Страница 170: ...For Pwr rail A error complete the following steps 1 Trained technician only Replace the system board 2 Trained technician only Replace the microprocessor c For other rail errors Pwr rail A error see step b remove each component that is associated with the faulty Pwr rail one at a time in the sequence indicated in Table 15 Components associated with power rail errors on page 158 restarting the serv...

Страница 171: ...nformation to solve Ethernet controller problems The method that you use to test the Ethernet controller depends on which operating system you are using See the operating system documentation for information about Ethernet controllers and see the Ethernet controller device driver readme file Try the following procedures Step 1 Make sure that the correct device drivers which come with the server ar...

Страница 172: ... page 157 Corrupted data in CMOS memory or corrupted UEFI firmware can cause undetermined problems To reset the CMOS data use the CMOS clear jumper JP1 to clear the CMOS memory and override the power on password see Table 3 System board jumpers on page 30 for more information If you suspect that the UEFI firmware is corrupted see Recovering the server firmware UEFI update failure on page 162 If th...

Страница 173: ...guration ever worked What changes if any were made before the configuration failed Is this the original reported failure Diagnostic program type and version level Hardware configuration print screen of the system summary UEFI firmware level IMM firmware level Operating system software You can solve some problems by comparing the configuration and software setups between working and nonworking serv...

Страница 174: ...following sources Download the server firmware update from the World Wide Web Contact your Lenovo service representative To download the server firmware update package from the World Wide Web go to http www lenovo com support The flash memory of the server consists of a primary bank and a backup bank You must maintain a bootable UEFI firmware image in the backup bank If the server firmware in the ...

Страница 175: ...nd external cables and then remove the cover see Removing the cover on page 37 Step 11 Move the UEFI boot backup jumper JP7 from pins 2 and 3 back to the primary position pins 1 and 2 Step 12 Reinstall the cover see Replacing the cover on page 196 Step 13 Reconnect the power cord and any cables that you removed Step 14 Restart the server The system begins the power on self test POST If this does n...

Страница 176: ...ic com lenovo sysx imm2 doc printable_doc html Automated boot recovery ABR While the server is starting if the integrated management module II detects problems with the server firmware in the primary bank the server automatically switches to the backup firmware bank and gives you the opportunity to recover the firmware in the primary bank For instructions for recovering the UEFI firmware see Recov...

Страница 177: ...onfiguration there might be a problem with the system board To specify the number of consecutive restart attempts that will trigger the Nx boot failure feature in the Setup utility click System Settings Recovery POST Attempts POST Attempts Limit The available options are 3 6 9 and 255 disable Nx boot failure Chapter 4 Troubleshooting 165 ...

Страница 178: ...166 Lenovo System x3650 M4 HD Installation and Service Guide ...

Страница 179: ...ent of Tier 1 CRUs is your responsibility If Lenovo installs a Tier 1 CRU at your request you will be charged for the installation Tier 2 customer replaceable unit You may install a Tier 2 CRU yourself or request Lenovo to install it at no additional charge under the type of warranty service that is designated for your server For information about the terms of the warranty and getting service and ...

Страница 180: ...00000 000 000 0 00 0000 0000 0000 0000 0000 21 22 23 26 1 3 7 8 9 15 19 11 12 4 18 20 24 13 10 16 25 17 14 5 6 2 Figure 100 Server components The following table lists the part numbers for the server replaceable components 168 Lenovo System x3650 M4 HD Installation and Service Guide ...

Страница 181: ... 80 W 00Y2780 7 Microprocessor Intel Xeon E5 2628L v2 8 core 1 9 GHz 20 MB 1600 MHz 70 W 00AE525 7 Microprocessor Intel Xeon E5 2630 v2 6 core 2 6 GHz 15 MB 1600 MHz 80 W 00Y2781 7 Microprocessor Intel Xeon E5 2630L v2 6 core 2 6 GHz 15 MB 1600 MHz 60 W 00Y2792 7 Microprocessor Intel Xeon E5 2637 v2 4 core 3 5 GHz 15 MB 1866 MHz 130 W 00Y2789 7 Microprocessor Intel Xeon E5 2640 v2 8 core 2 0 GHz 2...

Страница 182: ...AL055 12 Power supply 550 Watt ac Acbel 94Y8105 12 Power supply 550 Watt Emerson 94Y8065 12 Power supply 750 Watt high efficiency ac Delta 69Y5747 12 Power supply 750 Watt ac Delta This part is interchangeable with part number 94Y8071 94Y8079 12 Power supply 750 Watt ac Emerson This part is interchangeable with part number 94Y8079 94Y8071 12 Power supply 750 Watt dc Emerson 69Y5742 12 Power supply...

Страница 183: ...ID M5210 SAS SATA adapter 46C9111 ServeRAID M5200 series 1 GB cache RAID 5 upgrade 47C8657 ServeRAID M5200 series 1 GB flash RAID 5 upgrade 47C8661 ServeRAID M5200 series 2 GB flash RAID 5 upgrade 47C8665 365 GB High IOPS MLC mono adapter 00AE814 785 GB High IOPS MLC mono adapter 00AE815 Hypervisor embedded USB flash device 42D0545 Broadcom NetXtreme II 1000 Express Ethernet adapter 39Y6070 Broadc...

Страница 184: ...r NVIDIA Quadro K2000 90Y2379 QLogic 8 Gb FC single port HBA 00Y5628 QLogic 8 Gb FC dual port HBA 00Y5629 Qlogic 10 Gb converged network adapter CNA 00Y3274 QLogic 10 Gb virtual fabric and SR optical transceiver 42C1816 QLogic 10 Gb CNA 90Y4605 Kit keyboard video and mouse cables 00X6366 USB connector 44E8877 Tool USB keyboard US English layout and USB mouse 3 button optical 85Y7355 Battery 3 0 vo...

Страница 185: ...e mini SAS 925 mm 00Y7674 Cable rear backplane configuration 00Y8435 Cable rear backplane mini SAS 00Y8434 Cable rear backplane power 00J6562 Cable flash power module 46C9793 Cable 6Gbps external mini SAS SFF 8088 to SFF 8088 1 m 00YE299 Cable 6Gbps external mini SAS SFF 8088 to SFF 8088 2 m 00YE300 Cable 6Gbps external mini SAS SFF 8088 to SFF 8088 4 m 00YE301 Cable 6Gbps external mini SAS SFF 80...

Страница 186: ...0MP352 1 See Server features and specifications on page 6 for more details Structural parts Structural parts are not covered by the Lenovo Statement of Limited Warranty The following structural parts are available for purchase from the retail store Table 17 Structural parts Type 5460 Index Description Part number 1 Top cover 00AM237 9 Safety cover 94Y6619 10 Filler power supply bay 94Y7610 Filler ...

Страница 187: ...rts then follow the instructions to order the part from the retail store Note Changes are made periodically to the Lenovo website The actual procedure might vary slightly from what is described in this document If you need help with your order call the toll free number that is listed on the retail parts page or contact your Lenovo sales representative or Lenovo reseller for assistance Power cords ...

Страница 188: ...zakhstan Kyrgyzstan Laos People s Democratic Republic of Latvia Lebanon Lithuania Luxembourg Macedonia former Yugoslav Republic of Madagascar Mali Martinique Mauritania Mauritius Mayotte Moldova Republic of Monaco Mongolia Morocco Mozambique Netherlands New Caledonia Niger Norway Poland Portugal Reunion Romania Russian Federation Rwanda Sao Tome and Principe Saudi Arabia Senegal Serbia Slovakia Sl...

Страница 189: ...lic Ecuador El Salvador Guam Guatemala Haiti Honduras Jamaica Mexico Micronesia Federal States of Netherlands Antilles Nicaragua Panama Peru Philippines Saudi Arabia Thailand Taiwan United States of America Venezuela 39M5219 Korea Democratic People s Republic of Korea Republic of 39M5199 Japan 39M5068 Argentina Paraguay Uruguay 39M5226 India 39M5240 Brazil Chapter 5 Parts listing Lenovo System x36...

Страница 190: ...178 Lenovo System x3650 M4 HD Installation and Service Guide ...

Страница 191: ...ether a component is a structural part Tier 1 CRU or Tier 2 CRU For information about the terms of the warranty see the Warranty Information document that comes with the server For more information about getting service and assistance see Appendix D Getting help and technical assistance on page 1135 Returning a device or component If you are instructed to return a device or component follow all pa...

Страница 192: ...rmation panel cable To remove the operator information panel cable slightly press the cable toward the fan cage then pull to remove the cable from the connector on the system board Pulling the cable out of the connector by excessive force might cause damage to the cable or connector To connect the operator information panel cable on the system board press evenly on the cable Pressing on one side o...

Страница 193: ...erator information panel cable connection Cabling video graphic adapter The internal routing and connectors for the video graphic adapter cables The following illustration shows the internal routing and connectors for the video graphic adapter cables Chapter 6 Removing and replacing components 181 ...

Страница 194: ...ling backplane The internal routing and connectors for the backplanes Attention Please note that the mini SAS cables for some systems do not connect to the system board but to the RAID adapters 16x2 5 inch drive model The internal routing and connectors for the 16x2 5 inch drive model cables The following illustration shows the internal routing and connectors for the 16x2 5 inch hot swap HDD model...

Страница 195: ...ini SAS cable Power cable Configuration cable Backplane connection cable Figure 104 16x2 5 inch hot swap HDD model cable connection The following illustration shows the internal routing and connectors for the 16x2 5 inch hot swap HDD model cables Chapter 6 Removing and replacing components 183 ...

Страница 196: ...ch hot swap HDD model cable connection 24x2 5 inch drive model with expander The internal routing and connectors for the 24x2 5 inch drive model with expander cables The following illustration shows the internal routing and connectors for the 24x2 5 inch hot swap HDD model with expander 184 Lenovo System x3650 M4 HD Installation and Service Guide ...

Страница 197: ... Backplane connection cable SAS 0 SAS 1 Power cable Configuration cable Port 1 Port 0 Figure 106 24x2 5 inch hot swap HDD model with expander cable connection The following illustration shows the internal routing and connectors for the 24x2 5 inch hot swap HDD model with expander cables Chapter 6 Removing and replacing components 185 ...

Страница 198: ...4x2 5 inch drive model The internal routing and connectors for the 24x2 5 inch drive model cables The following illustration shows the internal routing and connectors for the 24x2 5 inch hot swap HDD model Note Make sure that Port 1 on the hardware ServeRAID is connected to Port 1 on the backplane Likewise Port 0 on the hardware ServeRAID should be connected to Port 0 on the backplane 186 Lenovo S...

Страница 199: ...er cable Configuration cable Backplane connection cable SAS 0 SAS 1 Power cable Configuration cable Port 0 Port 1 Port 1 Port 0 Port 0 Port 1 Figure 108 24x2 5 inch hot swap HDD model cable connection applicable to FLATWOODS ServeRAID M5210 SAS SATA Controller Chapter 6 Removing and replacing components 187 ...

Страница 200: ...SAS 0 SAS 1 Power cable Configuration cable Port 1 Port 0 Port 1 Port 0 Port 0 Port 1 Figure 109 24x2 5 inch hot swap HDD model cable connection applicable to RACINE RAID N2215 controller The following illustration shows the internal routing and connectors for the 24x2 5 inch hot swap HDD model cables 188 Lenovo System x3650 M4 HD Installation and Service Guide ...

Страница 201: ...nch drive model with 3 same backplanes The internal routing and connectors for the 24x2 5 inch drive model cables The following illustration shows the internal routing and connectors for the 24x2 5 inch hot swap HDD model Note Make sure that Port 1 on the hardware ServeRAID is connected to Port 1 on the backplane Likewise Port 0 on the hardware ServeRAID should be connected to Port 0 on the backpl...

Страница 202: ... Configuration cable SAS 0 SAS 1 Power cable Configuration cable Port 0 Port 1 Riser 1 Riser 2 Port 0 Port 1 Port 0 Port 1 Port 0 Port 1 Figure 111 24x2 5 inch hot swap HDD model cable connection applicable to FLATWOODS ServeRAID M5210 SAS SATA Controller 190 Lenovo System x3650 M4 HD Installation and Service Guide ...

Страница 203: ...e Configuration cable Port 1 Port 0 Riser 1 Riser 2 Port 0 Port 1 Port 0 Port 1 Port 0 Port 1 Figure 112 24x2 5 inch hot swap HDD model cable connection applicable to RACINE RAID N2215 controller The following illustration shows the internal routing and connectors for the 24x2 5 inch hot swap HDD model cables Chapter 6 Removing and replacing components 191 ...

Страница 204: ...rive model The internal routing and connectors for the 16x2 5 inch and 16x1 8 inch drive model cables The following illustration shows the internal routing and connectors for the 16x2 5 inch and 16x1 8 inch drive model Note Make sure that Port 1 on the hardware ServeRAID is connected to Port 1 on the backplane Likewise Port 0 on the hardware ServeRAID should be connected to Port 0 on the backplane...

Страница 205: ...le Backplane connection cable SAS 0 SAS 1 Power cable Configuration cable Mini SAS cable Port 0 Port 1 Riser 1 Riser 2 Port 0 Port 1 Port 0 Port 1 Figure 114 16x2 5 inch and 16x1 8 inch drive model cable connection applicable to FLATWOODS ServeRAID M5210 SAS SATA Controller Chapter 6 Removing and replacing components 193 ...

Страница 206: ...uration cable Mini SAS cable Port 1 Port 0 Riser 1 Riser 2 Port 0 Port 1 Port 0 Port 1 Figure 115 16x2 5 inch and 16x1 8 inch drive model cable connection applicable to RACINE RAID N2215 controller The following illustration shows the internal routing and connectors for the 16x2 5 inch and 16x1 8 inch drive model cables 194 Lenovo System x3650 M4 HD Installation and Service Guide ...

Страница 207: ...Replacement of structural parts is your responsibility If Lenovo installs a structural part at your request you will be charged for the installation The illustrations in this document might differ slightly from your hardware Removing the cover Use this information to remove the cover To remove the server cover complete the following steps Step 1 Read the safety information that begins on page Safe...

Страница 208: ...er cover complete the following steps Step 1 Make sure that all cables adapters and other components are installed and seated correctly and that you have not left loose tools or parts inside the server Also make sure that all internal cables are correctly routed Before you slide the cover forward make sure that all the tabs on the front rear and side of the cover engage the chassis correctly If al...

Страница 209: ...al cables and power cords Removing the bezel Use this information to remove the bezel To remove the bezel complete the following steps Step 1 Read the safety information that begins on Safety on page v and Installation guidelines on page 34 Step 2 Remove all the cables that are connected to the front of the server Step 3 Remove the screws from the bezel Note Use the hex screw driver to remove the ...

Страница 210: ...te the following steps Step 1 Read the safety information that begins on Safety on page v and Installation guidelines on page 34 Step 2 Turn off the server and peripheral devices and disconnect the power cords and all external cables if necessary Step 3 Reinstall the operator information panel assembly in the bezel if it has been removed earlier see Replacing the operator information panel assembl...

Страница 211: ...ing steps Step 1 Read the safety information that begins on page Safety on page v and Installation guidelines on page 34 Step 2 Turn off the server and peripheral devices and disconnect the power cords and all external cables see Turning off the server on page 23 Step 3 Remove the cover see Removing the cover on page 195 Step 4 Remove PCI riser card assemblies if necessary see Removing a PCI riser...

Страница 212: ...he air baffle complete the following steps Step 1 Read the safety information that begins on page Safety on page v and Installation guidelines on page 34 Step 2 Turn off the server and peripheral devices and disconnect the power cords and all external cables Step 3 Remove the cover see Removing the cover on page 195 Step 4 Align the air baffle pins with the baffle pin holes on both sides of the ch...

Страница 213: ...the peripheral devices and the server Removing a RAID adapter battery or flash power module Use this information to remove a RAID adapter battery or flash power module If a RAID adapter battery or flash power module is installed near the fan cage and you need to replace it complete the following steps Step 1 Read the safety information that begins on Safety on page v and Installation guidelines on...

Страница 214: ...Release tab Figure 123 Cover open Step 5 Lift the battery or flash power module up to remove it from the holder 202 Lenovo System x3650 M4 HD Installation and Service Guide ...

Страница 215: ... install any RAID adapter that comes with batteries or flash power modules it is sometimes necessary to install the batteries or flash power modules in another location in the server to prevent the batteries or flash power modules from overheating The batteries or flash power modules must be installed on top of the air baffle Important The battery must recharge for at least 6 hours under normal op...

Страница 216: ...air baffle Release tab Figure 125 Holder cover open Step 6 Connect one end of the cable to the ServeRAID memory module Step 7 Route the battery or flash power module cable along the chassis Attention Make sure that the cable is not pinched and does not cover any connectors or obstruct any components on the system board Step 8 Install the battery or flash power module on top of the air baffle a Ali...

Страница 217: ...f the batteries or flash power modules that you install b Connect the other end of the cable to the battery or flash power module 00000 00000 00000 00000 00000 00000 Flash power module cable ServeRAID memory module Flash power module Figure 127 Battery or flash power module cable installation Note Make sure the battery or flash power module is seated properly Chapter 6 Removing and replacing compo...

Страница 218: ...remove the safety cover Removing the 240 VA safety cover Use this information to remove the 240 VA safety cover To remove the 240 VA safety cover complete the following steps Step 1 Read the safety information that begins on Safety on page v and Installation guidelines on page 34 Step 2 Turn off the server and disconnect all power cords and external cables Step 3 Remove the cover see Removing the ...

Страница 219: ...s and use any packaging materials for shipping that are supplied to you Removing the power paddle card cover Use this information to remove the power paddle card cover To remove the power paddle card cover complete the following steps Step 1 Read the safety information that begins on Safety on page v and Installation guidelines on page 34 Step 2 Turn off the server and disconnect all power cords a...

Страница 220: ...ce the safety cover Replacing the 240 VA safety cover Use this information to replace the 240 VA safety cover To install the 240 VA safety cover complete the following steps Step 1 Read the safety information that begins on Safety on page v and Installation guidelines on page 34 Step 2 Turn off the server and peripheral devices and disconnect the power cords and all external cables if necessary St...

Страница 221: ...er cords and all external cables and turn on the server and peripheral devices Replacing the power paddle card cover Use this information to replace the power paddle card cover To install the power paddle card cover complete the following steps Step 1 Read the safety information that begins on Safety on page v and Installation guidelines on page 34 Step 2 Turn off the server and peripheral devices...

Страница 222: ...ttention To avoid damage to the hard disk drive connectors make sure that the server cover is in place and fully closed whenever you install or remove a hard disk drive To make sure that there is adequate system cooling do not operate the server for more than 2 minutes without either a hard disk drive or a filler panel installed in each bay Before you make changes to disk drives disk drive control...

Страница 223: ...0 0000 000 000 000 000 1 8 inch hot swap hard disk drive Handle Filler Release latch Figure 134 1 8 inch hot swap solid state drives removal b Slide the release latch orange down gently to unlock the drive handle Step 5 Grasp the handle and slide the drive out of the drive bay Step 6 Reinstall the drive bay filler panel if necessary Step 7 If you are instructed to return the drive follow all packa...

Страница 224: ...that you later remove the device For a complete list of supported optional devices for the server see http www lenovo com serverproven To install a hot swap drive complete the following steps Note If you have only one drive you must install it in bay 0 Step 1 Read the safety information that begins on Safety on page v and Installation guidelines on page 34 Step 2 Remove the filler panel Keep the f...

Страница 225: ...igured for RAID operation using a ServeRAID adapter you might have to reconfigure your disk arrays after you install hard disk drives See the ServeRAID adapter documentation for additional information about RAID operation and complete instructions for using the ServeRAID adapter Step 7 If you are installing additional hot swap hard disk drives do so now Step 8 Turn on the peripheral devices and th...

Страница 226: ...16 31 2 5 inch hard disk drive bays 0 15 Figure 139 Front view 2 5 inch and 1 8 inch hot swap drive IDs Removing a memory module Use this information to remove a memory module To remove a dual inline memory module DIMM complete the following steps Step 1 Read the safety information that begins on Safety on page v and Installation guidelines on page 34 Step 2 Turn off the server and peripheral devi...

Страница 227: ... DDR3 800 1066 1333 1600 or 1866 MHz PC3 6400 PC3 8500 PC3 10600 PC3 12800 or PC3 14900 registered or unbuffered synchronous dynamic random access memory SDRAM dual inline memory modules DIMMs with error correcting code ECC See http www lenovo com serverproven for a list of supported memory modules for the server The specifications of a DDR3 DIMM are on a label on the DIMM in the following format ...

Страница 228: ...on the label is in the format xxxxx nRxxx PC3v xxxxxx xx xx xxx The numeral in the sixth numerical position indicates whether the DIMM is single rank n 1 dual rank n 2 or quad rank n 4 The following rules apply to DDR3 RDIMM speed as it relates to the number of RDIMMs in a channel When you install 1 RDIMM per channel the memory runs at 1866 MHz When you install 2 RDIMMs per channel the memory runs...

Страница 229: ...epending on the system configuration A certain amount of memory must be reserved for system resources To view the total amount of installed memory and the amount of configured memory run the Setup utility For additional information see Configuring the server on page 100 A minimum of one DIMM must be installed for each microprocessor For example you must install a minimum of two DIMMs if the server...

Страница 230: ...uence One microprocessor installed 1 4 9 12 2 5 8 11 3 6 7 10 Two microprocessors installed 1 13 4 16 9 21 12 24 2 14 5 17 8 20 11 23 3 15 6 18 7 19 10 22 Memory mirrored channel Memory mirrored channel mode replicates and stores data on two pairs of DIMMs within two channels simultaneously If a failure occurs the memory controller switches from the primary pair of memory DIMMs to the backup pair ...

Страница 231: ...MM connector First pair of DIMMs 1 1 4 Second pair of DIMMs 1 9 12 Third pair of DIMMs 1 2 5 Fourth pair of DIMMs 1 8 11 Fifth pair of DIMMs 1 3 6 Sixth pair of DIMMs 1 7 10 Seventh pair of DIMMs 2 13 16 Eighth pair of DIMMs 2 21 24 Ninth pair of DIMMs 2 14 17 Tenth pair of DIMMs 2 20 23 Eleventh pair of DIMMs 2 15 18 Twelfth pair of DIMMs 2 19 22 Note DIMM connectors 3 6 7 10 15 18 19 and 22 are ...

Страница 232: ...inth pair of DIMMs 2 20 21 Tenth pair of DIMMs 2 23 24 Eleventh pair of DIMMs 2 19 22 Twelfth pair of DIMMs 2 15 18 Note DIMM connectors 3 6 7 10 15 18 19 and 22 are not used in memory rank sparing mode when UDIMMs are installed in the server Replacing a memory module Use this information to replace a memory module Step 1 Read the safety information that begins on Safety on page v and Installation...

Страница 233: ...e on both ends of the DIMM simultaneously The retaining clips snap into the locked position when the DIMM is firmly seated in the connector Note If there is a gap between the DIMM and the retaining clips the DIMM has not been correctly inserted open the retaining clips remove the DIMM and then reinsert it Step 11 Reconnect the power cords and any cables that you removed Step 12 Replace the air baf...

Страница 234: ...server Place the riser card assembly on a flat static protective surface 0 0 0 0 0 0 0 000 000 00 00 000000 000000 000000 000000 0000 0000 0000 0000 0000 0 0 000000 000000 000000 000000 000 000 000 PCI riser card assembly 2 PCI riser card assembly 1 Figure 145 PCI riser card assembly removal Replacing a PCI riser card assembly The server provides two PCI riser card slots on the system board The fo...

Страница 235: ...assembly complete the following steps Step 1 Read the safety information that begins on Safety on page v and Installation guidelines on page 34 Step 2 Turn off the server and peripheral devices and disconnect all power cords Step 3 Remove the cover see Removing the cover on page 195 Step 4 Reinstall any adapters and reconnect any internal cables you might have removed in other procedures see Repla...

Страница 236: ...tor on the system board Step 7 Replace the cover see Replacing the cover on page 196 Step 8 Slide the server into the rack Step 9 Reconnect the power cords and any cables that you removed Step 10 Turn on the peripheral devices and the server Removing the rear two hard disk drive kit The server comes with one rear two hard disk drive kit See http www lenovo com serverproven for a list of hard disk ...

Страница 237: ...s information to replace the rear two hard disk drive kit on the system board To install the rear two hard disk drive kit complete the following steps Step 1 Read the safety information that begins on Safety on page v and Installation guidelines on page 34 Step 2 Turn off the server and peripheral devices and disconnect all power cords Step 3 Remove the cover see Removing the cover on page 195 Ste...

Страница 238: ...nformation to remove an adapter Removing an adapter from a PCI riser card assembly Use this information to remove an adapter from a PCI expansion slot in a PCI riser card assembly These instructions apply to PCI adapters such as video graphic adapters and network adapters The following table shows the locations of the adapter expansion slots from the rear of the server Table 22 The maximum adapter...

Страница 239: ...rs PCI riser card assembly in short position Adapter Adapter connectors Full length adapter bracket Full length adapter bracket Figure 149 Adapter removal Step 4 Disconnect any cables from the adapter make note of the cable routing in case you reinstall the adapter later Step 5 Carefully grasp the adapter by its top edge or upper corners and pull the adapter from the PCI expansion slot Step 6 If t...

Страница 240: ...kup or record its configuration information if possible before replacing the adapter See the documentation for your adapter for information and instructions If you are replacing a ServeRAID adapter import your RAID configuration to the replacement adapter as a foreign configuration after you finish the replacement See the ServeRAID M Software User Guide at https support lenovo com us en documents ...

Страница 241: ...riser card option If you are installing a ServeRAID M5110 or ServeRAID M5120 adapter it can only be installed in PCI slot 1 2 4 or 5 The following table shows the locations of the adapter expansion slots from the rear of the server Table 23 The maximum adapter dimension supported in each slot rear view PCI riser card assembly 1 PCI riser card assembly 2 1 Full height up to full length 4 Full heigh...

Страница 242: ... and keep it in a safe place for potential future use 00 0000 0000 0000 0000 0000 0000 0000000 0000000 0000000 0000000 PCI riser card assembly Full length adapter bracket Figure 152 Full length adapter bracket removal b Riser card assembly 2 if the adapter is a full length adapter for the upper expansion slot in the riser card the full length adapter bracket is on the cage by default Step 6 Align ...

Страница 243: ... required for the adapter Step 11 Reinstall the cover see Replacing the cover on page 196 Step 12 Slide the server into the rack Step 13 Reconnect the power cords and any cables that you removed Step 14 Turn on the peripheral devices and the server Replacing an adapter in the rear two hard disk drive kit Use this information to replace an adapter in the rear two hard disk drive kit You can only in...

Страница 244: ...rd disk drive kit on page 225 Step 10 Perform any configuration tasks that are required for the adapter Step 11 Reinstall the cover see Replacing the cover on page 196 Step 12 Slide the server into the rack Step 13 Reconnect the power cords and any cables that you removed Step 14 Turn on the peripheral devices and the server Removing the ServeRAID adapter memory module Use this information to remo...

Страница 245: ...re 155 Cable removal Step 5 Remove the ServeRAID adapter memory module from the system board Connector Rentention pins ServeRAID memory module Figure 156 ServeRAID adapter memory module removal Step 6 Disconnect the cable from the ServeRAID adapter memory module Chapter 6 Removing and replacing components 233 ...

Страница 246: ...lete the following steps Step 1 Read the safety information that begins on Safety on page v and Installation guidelines on page 34 Step 2 Turn off the server and peripheral devices and disconnect all power cords Step 3 Remove the cover see Removing the cover on page 195 Step 4 Connect the cable to the ServeRAID adapter memory module ServeRAID memory module Flash power module cable Figure 158 Cable...

Страница 247: ...lation Note Make sure the flash power module is seated properly see Replacing a RAID adapter battery or flash power module on page 203 Step 7 Reconnect the power cords and any cables that you removed Step 8 Reinstall the cover see Replacing the cover on page 196 Step 9 Slide the server into the rack Step 10 Turn on the peripheral devices and the server Removing the dual port network adapter Use th...

Страница 248: ...ee Removing a PCI riser card assembly on page 221 Step 5 Loosen the two captive screws on the network adapter from the screw holes on the system board 00 00 00 00 00 0 0 00 000 000 000 000 000 Pin Thumbscrew Retention brackets Captive screws Figure 161 Screws disengagement Step 6 Loosen the thumbscrew on the chassis Step 7 Grasp the network adapter and disengage it from the pin retention brackets ...

Страница 249: ...e network connector Dual port network adapter Option part number FRU part number Qlogic dual port 10GbE SFP Embedded VFA 90Y6454 90Y5099 Dual port FDR embedded adapter 00D4143 00J6248 The following notes describe the types of adapters that the server supports and other information that you must consider when you install an adapter To configure network adapters complete the following steps 1 From t...

Страница 250: ...lightly from what is described in this document Port 0 on the Emulex Dual Port 10GbE SFP Embedded VFA III can be configured as shared system management When the server is in standby mode both ports on the Emulex Dual Port 10GbE SFP Embedded VFA III function at 100M connection speed with Wake on LAN feature The Emulex Dual Port 10GbE SFP Embedded VFA III is automatically disabled if one of the foll...

Страница 251: ...t contains the new adapter to any unpainted metal surface on the server Then remove the adapter from the package Step 7 Align the adapter so that the port connectors on the adapter line up with the pin and thumbscrew on the chassis then align the connector of the adapter with the adapter connector on the system board Chapter 6 Removing and replacing components 239 ...

Страница 252: ...tention brackets engage the adapter Make sure the adapter is securely seated on the connector on the system board Attention Make sure the port connectors on the adapter are aligned properly with the chassis on the rear of the server An incorrectly seated adapter might cause damage to the system board or the adapter Step 9 Fasten the thumbscrew on the rear side of the chassis 240 Lenovo System x365...

Страница 253: ... and the server Removing a hot swap fan Use this information to remove a hot swap fan Attention To ensure proper server operation replace a failed hot swap fan within 30 seconds To remove a hot swap fan complete the following steps Step 1 Read the safety information that begins on Safety on page v and Installation guidelines on page 34 Step 2 Remove the cover see Removing the cover on page 195 The...

Страница 254: ...30 seconds To replace a hot swap fan complete the following steps Step 1 Read the safety information that begins on Safety on page v and Installation guidelines on page 34 Step 2 Remove the cover see Removing the cover on page 195 Step 3 Rotate the air baffle up Step 4 Touch the static protective package that contains the new fan to any unpainted metal surface on the server Then remove the new fan...

Страница 255: ...acket See Removing a hot swap fan on page 241 and Replacing a hot swap fan on page 242 To remove the fan bracket complete the following steps Step 1 Read the safety information that begins on Safety on page v and Installation guidelines on page 34 Step 2 Turn off the server and peripheral devices and disconnect the power cords and all external cables Step 3 Remove the cover see Removing the cover ...

Страница 256: ...river Screws Figure 168 Fan bracket screws removal b Press the fan bracket release latches toward each other and lift the fan bracket out of the server 244 Lenovo System x3650 M4 HD Installation and Service Guide ...

Страница 257: ...ket complete the following steps Step 1 Read the safety information that begins on Safety on page v and Installation guidelines on page 34 Step 2 Turn off the server and peripheral devices and disconnect all power cords Step 3 Remove the cover see Removing the cover on page 195 Step 4 Lower the fan bracket into the chassis Chapter 6 Removing and replacing components 245 ...

Страница 258: ...ith the pins in the bottom of the chassis Step 6 Press the bracket into position until the fan bracket release levers click into place Step 7 Install the three screws in the fan bracket if present Note Use the hex screw driver to install the screws 246 Lenovo System x3650 M4 HD Installation and Service Guide ...

Страница 259: ...oving a power supply Use this information to remove a power supply Removing a hot swap ac power supply Observe the following precautions when you remove a hot swap ac power supply Statement 5 CAUTION The power control button on the device and the power switch on the power supply do not turn off the electrical current supplied to the device The device also might have more than one power cord To rem...

Страница 260: ...pply complete the following steps Step 1 Read the safety information that begins on Safety on page v and Installation guidelines on page 34 Step 2 If only one power supply is installed turn off the server and peripheral devices and disconnect all power cords Step 3 If the server is in a rack at the back of the server pull back the cable management arm to gain access to the rear of the server and t...

Страница 261: ...cuit to the earthing conductor at the equipment If this connection is made all of the following conditions must be met This equipment shall be connected directly to the dc supply system earthing electrode conductor or to a bonding jumper from an earthing terminal bar or bus to which the dc supply system earthing electrode conductor is connected This equipment shall be located in the same immediate...

Страница 262: ...ttached to this product 2 Attach signal cables to the product 3 Attach power cords to the product For ac systems use appliance inlets For dc systems ensure correct polarity of 48 V dc connections RTN is and 48 V dc is Earth ground should use a two hole lug for safety 4 Attach signal cables to other devices 5 Connect power cords to their sources 6 Turn ON all the power sources 1 Turn OFF all power ...

Страница 263: ...er wire conductors only See the specifications in the product documentation for the required wire size See the specifications in the product documentation for the required torque values for the wiring terminal screws Important Be sure to read the multilingual safety instructions on the CD that comes with the server before you use the product To remove a hot swap dc power supply complete the follow...

Страница 264: ...ay use the Power Configurator utility to determine current system power consumption For more information and to download the utility go to http www ibm com systems bladecenter resources powerconfig html The server comes with one hot swap 12 volt output power supply that connects to power supply bay 1 The input voltage is 100 127 V ac or 200 240 V ac auto sensing Power supplies in the server must b...

Страница 265: ... this label attached There are no serviceable parts inside these components If you suspect a problem with one of these parts contact a service technician To install a hot swap ac power supply complete the following steps Step 1 Read the safety information that begins on Safety on page v and Installation guidelines on page 34 Step 2 Touch the static protective package that contains the hot swap pow...

Страница 266: ...wer supply to the power cord connector on the power supply The following illustration shows the power cord connectors on the rear of the server 0 000 000 000 000 0 00 00 000 000 000 000 000 00 0000 00 00 000 000 000 000 000 000 0000000 0000000 0000000 0000000 0000000 0000000 0000000 0000000 0000000 0000000 0000000 0000000 Power cord connectors Figure 175 Power cord connectors on rear of server Ste...

Страница 267: ... supports and other information that you must consider when you install a power supply Before you install an additional power supply or replace a power supply with one of a different wattage you may use the Power Configurator utility to determine current system power consumption For more information and to download the utility go to http www ibm com systems bladecenter resources powerconfig html T...

Страница 268: ...ON This equipment is designed to permit the connection of the earthed conductor of the dc supply circuit to the earthing conductor at the equipment This equipment is designed to permit the connection of the earthed conductor of the dc supply circuit to the earthing conductor at the equipment If this connection is made all of the following conditions must be met This equipment shall be connected di...

Страница 269: ...at is to be attached to this product 2 Attach signal cables to the product 3 Attach power cords to the product For ac systems use appliance inlets For dc systems ensure correct polarity of 48 V dc connections RTN is and 48 V dc is Earth ground should use a two hole lug for safety 4 Attach signal cables to other devices 5 Connect power cords to their sources 6 Turn ON all the power sources 1 Turn O...

Страница 270: ...r the wiring terminal screws Important Be sure to read the multilingual safety instructions on the CD that comes with the server before you use the product Replacing a hot swap dc power supply Use this information to replace a hot swap dc power supply To install a hot swap dc power supply complete the following steps Attention Only trained service personnel other than Lenovo service technicians ar...

Страница 271: ...y and slide the power supply forward into the power supply bay until it clicks Make sure that the power supply connects firmly into the power supply connector Step 7 Route the power cord through the handle and cable tie if any so that it does not accidentally become unplugged Step 8 Connect the other ends of the dc power cable to the dc power source Cut the wires to the correct length but do not c...

Страница 272: ...ach the redundant power information label that comes with this power supply on the server cover near the power supplies Figure 181 Redundant power information label Removing the hot swap drive backplane Use this information to remove the hot swap drive backplane Attention 1 Before removing any components or disconnecting any cables keep note of their respective locations and how they are connected...

Страница 273: ...supplied to you Replacing the hot swap drive backplane Use this information to replace the hot swap drive backplane Attention 1 Before removing any components or disconnecting any cables keep note of their respective locations and how they are connected to the system board To replace the hot swap hard disk drive backplane complete the following steps Step 1 Read the safety information that begins ...

Страница 274: ...8 inch SSD backplane assembly Attention 1 Before removing any components or disconnecting any cables keep note of their respective locations and how they are connected to the system board To remove the 8x1 8 inch hot swap SSD backplane assembly complete the following steps Step 1 Read the safety information that begins on Safety on page v and Installation guidelines on page 34 Step 2 Turn off the ...

Страница 275: ...kaging instructions and use any packaging materials for shipping that are supplied to you Replacing the 8x1 8 inch SSD backplane assembly Use this information to replace the 8x1 8 inch SSD backplane assembly Attention 1 Before removing any components or disconnecting any cables keep note of their respective locations and how they are connected to the system board To replace the 8x1 8 inch hot swap...

Страница 276: ...embly into the new drive backplane assembly see Replacing a hot swap drive on page 211 Step 8 Install the drive filler panel Step 9 Install the cover see Replacing the cover on page 196 Step 10 Slide the server into the rack Step 11 Reconnect the power cords and any cables that you removed Step 12 Turn on the peripheral devices and the server Removing a USB embedded hypervisor flash device Use thi...

Страница 277: ... supplied to you Replacing a USB embedded hypervisor flash device Use this information to replace a USB embedded hypervisor flash device To install a USB hypervisor flash device complete the following steps Step 1 Read the safety information that begins on Safety on page v and Installation guidelines on page 34 Step 2 Turn off the server and peripheral devices and disconnect the power cords Step 3...

Страница 278: ...th your safety in mind The lithium battery must be handled correctly to avoid possible danger If you replace the battery you must adhere to the following instructions Note In the U S call 1 800 IBM 4333 for information about battery disposal If you replace the original lithium battery with a heavy metal battery or a battery with heavy metal components be aware of the following environmental consid...

Страница 279: ... or immerse into water Heat to more than 100 C 212 F Repair or disassemble Dispose of the battery as required by local ordinances or regulations To remove the system battery complete the following steps Step 1 Read the safety information that begins on Safety on page v and Installation guidelines on page 34 Step 2 Turn off the server and peripheral devices and disconnect the power cords and all ex...

Страница 280: ...9 System battery removal c Use your thumb and index finger to lift the battery from the socket Attention Do not lift the battery by using excessive force Failing to remove the battery properly may damage the socket on the system board Any damage to the socket may require replacing the system board Step 6 Dispose of the battery as required by local ordinances or regulations See the Lenovo Environme...

Страница 281: ...em has a module containing a lithium battery replace it only with the same module type made by the same manufacturer The battery contains lithium and can explode if not properly used handled or disposed of Do not Throw or immerse into water Heat to more than 100 C 212 F Repair or disassemble Dispose of the battery as required by local ordinances or regulations To install the replacement system bat...

Страница 282: ...m the battery holder use your fingers to install the battery cover on top of the battery connector Step 7 Reinstall the PCI riser card assembly 2 see Replacing a PCI riser card assembly on page 222 if necessary Step 8 Install the cover see Replacing the cover on page 196 Step 9 Slide the server into the rack Step 10 Reconnect the external cables then reconnect the power cords and turn on the perip...

Страница 283: ...ins on Safety on page v and Installation guidelines on page 34 Step 2 Disconnect the cables connected to the front video and USB connectors Step 3 Loosen the two captive screws on the breakout cable Video and USB breakout cable Video connector USB port Video and USB breakout connector Figure 192 Breakout cable removal Step 4 Remove the breakout cable from the server If you are instructed to return...

Страница 284: ...igure 193 Breakout cable installation Step 3 Fasten the two captive screws on the breakout cable Removing the video and USB breakout signal cable Use this information to remove the video and USB breakout signal cable To remove the video and USB breakout signal cable complete the following steps Step 1 Read the safety information that begins on Safety on page v and Installation guidelines on page 3...

Страница 285: ...s that secure the KVM assembly to the side of the chassis then remove the KVM assembly Note Use the hex screw driver to remove the two screws Hex screw driver KVM connector assembly Figure 194 KVM assembly removal Step 7 Disconnect the front video and USB breakout signal cable from the system board Chapter 6 Removing and replacing components 273 ...

Страница 286: ...erator information panel cables from the cable clips and move them aside The power cable is present when the third backplane is installed in the server Cable clip Figure 196 SAS power and operator information panel cable removal Step 9 Remove the video and USB breakout signal cable from the cable clip then slide the cable out from the chassis 274 Lenovo System x3650 M4 HD Installation and Service ...

Страница 287: ... supplied to you Replacing the video and USB breakout signal cable Use this information to replace the video and USB breakout signal cable To install the video and USB breakout signal cable complete the following steps Step 1 Read the safety information that begins on Safety on page v and Installation guidelines on page 34 Step 2 Connect the video and USB breakout signal cable to the system board ...

Страница 288: ...gnal cable Figure 198 Connecting the video and USB breakout signal cable to the system board Step 3 Route the video and USB breakout signal cable along the chassis Make sure it passes through the relevant cable clips 276 Lenovo System x3650 M4 HD Installation and Service Guide ...

Страница 289: ...ws to secure the KVM assembly to the side of the chassis Note Use the hex screw driver to install the two screws Hex screw driver KVM connector assembly Figure 200 KVM assembly installation Step 5 Insert the SAS power and operator information panel cables into the cable clips The power cable is present when the third backplane is installed in the server Chapter 6 Removing and replacing components ...

Страница 290: ...ral devices and the server Removing the operator information panel assembly Use this information to remove the operator information panel assembly To remove the operator information panel complete the following steps Step 1 Read the safety information that begins on Safety on page v and Installation guidelines on page 34 Step 2 Turn off the server and peripheral devices and disconnect the power co...

Страница 291: ...anel removal Step 7 Carefully remove the assembly from the bezel Step 8 If you are instructed to return the operator information panel assembly follow all packaging instructions and use any packaging materials for shipping that are supplied to you Replacing the operator information panel assembly Use this information to replace the operator information panel assembly To install the operator inform...

Страница 292: ...formation panel installation Step 6 Replace the bezel see Replacing the bezel on page 198 Step 7 Connect the operator information cable from the system board to the rear of the assembly see Cabling operator information panel on page 180 Operator information panel cable Operator information panel assembly Figure 205 Operator information panel cable installation Step 8 Replace the cover see Replacin...

Страница 293: ...ard cover on page 207 Step 6 Remove the two screws from the power paddle card and lift it out of the server 0 0 0 0 0 0 0 Screws Power paddle card Figure 206 Power paddle card removal If you are instructed to return the power paddle card follow all packaging instructions and use any packaging materials for shipping that are supplied to you Replacing the power paddle card Use this information to re...

Страница 294: ...oprocessors are to be removed only by trained technicians Important Always use the microprocessor installation tool to remove a microprocessor Failing to use the microprocessor installation tool may damage the microprocessor sockets on the system board Any damage to the microprocessor sockets may require replacing the system board Be extremely careful the microprocessor socket contacts are very fr...

Страница 295: ...settings for installing two different sizes of microprocessors The settings that are marked on Tool B are L for smaller low core microprocessors and H for larger high core microprocessors Installation Tool B supports the following families of microprocessors E5 26xx E5 46xx E5 26xx v2 E5 46xx v2 Microprocessor Installation Tools A and B are shown in the following illustration H Microprocessor Inst...

Страница 296: ...h the thermal grease side up on a clean flat surface Figure 209 Heat sink removal Step 7 Open the microprocessor socket release levers and retainer Microprocessor Microprocessor release lever Microprocessor release lever Figure 210 Microprocessor socket levers and retainer disengagement a Identify which release lever is labeled as the first release lever to open and open it b Open the second relea...

Страница 297: ...ool B 1 lift the interlock latch and hold it up while you 2 twist the microprocessor installation tool handle counterclockwise to the open position and then release the interlock latch The following illustration of the installation tool shows the location of the interlock latch and counterclockwise rotation of the handle before loading the microprocessor H Figure 212 Installation tool handle adjus...

Страница 298: ...ition and lift the microprocessor out of the socket If using Installation Tool B gently twist the handle of the installation tool clockwise until it locks in the H or L position depending on the size of microprocessor and then lift the microprocessor out of the socket Handle Installation tool Microprocessor Figure 214 Installation tool handle adjustment d Lift the microprocessor out of the socket ...

Страница 299: ...r Failing to use the microprocessor installation tool may damage the microprocessor sockets on the system board Any damage to the microprocessor sockets may require replacing the system board Be extremely careful the microprocessor socket contacts are very fragile Do not touch the microprocessor socket contacts Contaminants on the microprocessor contacts or microprocessor socket contacts such as o...

Страница 300: ...or socket 1 Both microprocessor voltage regulator modules are integrated on the system board Read the documentation that comes with the microprocessor to determine whether you have to update the server firmware To download the latest level of server firmware and other code updates for your server go to http www ibm com support fixcentral The microprocessor speeds are automatically set for this ser...

Страница 301: ...e 34 Step 2 Turn off the server and peripheral devices and disconnect the power cords and all external cables Attention When you handle static sensitive devices take precautions to avoid damage from static electricity For details about handling these devices see Handling static sensitive devices on page 36 Step 3 Remove the cover see Removing the cover on page 195 Step 4 Remove the air baffle see ...

Страница 302: ... and the microprocessor socket Step 7 Install the microprocessor in the microprocessor socket a Open the packaging that contains the new microprocessor installation tool assembly and carefully remove the installation tool assembly from the package Note Do not touch the microprocessor contacts Contaminants on the microprocessor contacts such as oil from your skin can cause connection failures betwe...

Страница 303: ...on tool If using Installation Tool A twist the handle on the microprocessor tool assembly counterclockwise to the open position to insert the microprocessor into the socket and lift the installation tool out of the socket If using Installation Tool B twist the handle of the installation tool assembly counterclockwise until the microprocessor is inserted into the socket and lift the installation to...

Страница 304: ...he socket before you try to close the microprocessor retainer Do not touch the thermal material on the bottom of the heat sink or on top of the microprocessor Touching the thermal material will contaminate it Step 8 Remove the microprocessor socket cover tape or label from the surface of the microprocessor socket if one is present Store the socket cover in a safe place 292 Lenovo System x3650 M4 H...

Страница 305: ...ket levers and retainer engagement a Close the microprocessor retainer on the microprocessor socket b Identify which release lever is labeled as the first release lever to close and close it c Close the second release lever on the microprocessor socket Attention If you are installing a new heat sink do not set down the heat sink after you remove the plastic cover Do not touch the thermal grease on...

Страница 306: ...stallation c Align and place the heat sink on top of the microprocessor in the retention bracket thermal material side down d Press firmly on the heat sink e Rotate the heat sink retention module release lever to the closed position and hook it underneath the lock tab Step 11 Reinstall the air baffle see Replacing the air baffle on page 200 Step 12 Install the cover see Replacing the cover on page...

Страница 307: ...grease on the microprocessor and heat sink complete the following steps Step 1 Place the heat sink on a clean work surface Step 2 Remove the cleaning pad from its package and unfold it completely Step 3 Use the cleaning pad to wipe the thermal grease from the bottom of the heat sink Note Make sure that all of the thermal grease is removed Step 4 Use a clean area of the cleaning pad to wipe the the...

Страница 308: ...evices on page 36 and Installation guidelines on page 34 Step 2 Turn off the server and any attached devices Step 3 Turn off the peripheral devices and disconnect all power cords Attention When you replace the system board you must either update the server with the latest firmware or restore the pre existing firmware that the customer provides on a diskette or CD image Make sure that you have the ...

Страница 309: ...ystem battery see Removing the system battery on page 266 Step 15 Remove the hot swap fans see Removing a hot swap fan on page 241 Step 16 Remove the fan bracket see Removing the fan bracket on page 243 Step 17 Disconnect all cables from the system board Make a list of each cable as you disconnect it you can then use this as a checklist when you install the new system board see Internal cable rout...

Страница 310: ...ll packaging instructions and use any packaging materials for shipping that are supplied to you Attention Make sure to place the socket covers for the microprocessor sockets on the system board before returning the system board Replacing the system board Use this information to replace the system board Attention 1 When you reassemble the components in the server be sure to route all cables careful...

Страница 311: ...ue screen capture features on page 111 5 Reactivate any Features on Demand features Instructions for automating the activation of features and installing activation keys is in the IBM Features on Demand User s Guide To download the document go to https fod lenovo com lkms log in and click Help 6 Some cluster solutions require specific code levels or coordinated code updates If the device is part o...

Страница 312: ...toward the rear of the server until the latch clicks into place Step 5 Install the fan bracket see Replacing the fan bracket on page 245 Step 6 Install the hot swap fans see Replacing a hot swap fan on page 242 Note Remember to insert the hot swap drive backplane cables in between the hot swap fans as shown in the illustration Do not leave the cables on top of the hot swap fans 300 Lenovo System x...

Страница 313: ...n adapter on page 228 and Replacing a PCI riser card assembly on page 222 Step 15 Install the rear two hard disk drive kit if any see Replacing the rear two hard disk drive kit on page 225 Step 16 Install the cover see Replacing the cover on page 196 Step 17 Push the power supplies back into the server Step 18 Slide the server into the rack Step 19 Reconnect the power cords and any cables that you...

Страница 314: ...302 Lenovo System x3650 M4 HD Installation and Service Guide ...

Страница 315: ...The event was recorded for audit purposes usually a user action or a change of states that is normal behavior Warning The event is not as severe as an error but if possible the condition should be corrected before it becomes an error It might also be a condition that requires additional monitoring or maintenance Error The event is a failure or critical condition that impairs service or an expected...

Страница 316: ... the table for a list of events that automatically notify Support Table 25 Events that automatically notify Support Event ID Message String Automatically Notify Support 40000086 00000000 Test Call Home Generated by user arg1 Yes 40000087 00000000 Manual Call Home by user arg1 arg2 Yes 80010202 0701ffff Numeric sensor NumericSensorElementName going low lower critical has asserted Yes 80010902 0701f...

Страница 317: ... 806f010c 200affff Uncorrectable error detected for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 10 Yes 806f010c 200bffff Uncorrectable error detected for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 11 Yes 806f010c 200cffff Uncorrectable error detected for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 12 Yes 806f010c 200dffff Uncorrectable error d...

Страница 318: ...Drive 0 Yes 806f010d 0401ffff The Drive StorageVolumeElementName has been disabled due to a detected fault Drive 1 Yes 806f010d 0402ffff The Drive StorageVolumeElementName has been disabled due to a detected fault Drive 2 Yes 806f010d 0403ffff The Drive StorageVolumeElementName has been disabled due to a detected fault Drive 3 Yes 806f010d 0404ffff The Drive StorageVolumeElementName has been disab...

Страница 319: ...Drive 21 Yes 806f010d 0416ffff The Drive StorageVolumeElementName has been disabled due to a detected fault Drive 22 Yes 806f010d 0417ffff The Drive StorageVolumeElementName has been disabled due to a detected fault Drive 23 Yes 806f010d 0418ffff The Drive StorageVolumeElementName has been disabled due to a detected fault Drive 24 Yes 806f010d 0419ffff The Drive StorageVolumeElementName has been d...

Страница 320: ...rive StorageVolumeElementName for array ComputerSystemElementName Drive 4 Yes 806f020d 0405ffff Failure Predicted on drive StorageVolumeElementName for array ComputerSystemElementName Drive 5 Yes 806f020d 0406ffff Failure Predicted on drive StorageVolumeElementName for array ComputerSystemElementName Drive 6 Yes 806f020d 0407ffff Failure Predicted on drive StorageVolumeElementName for array Comput...

Страница 321: ... Yes 806f020d 0419ffff Failure Predicted on drive StorageVolumeElementName for array ComputerSystemElementName Drive 25 Yes 806f020d 041affff Failure Predicted on drive StorageVolumeElementName for array ComputerSystemElementName Drive 26 Yes 806f020d 041bffff Failure Predicted on drive StorageVolumeElementName for array ComputerSystemElementName Drive 27 Yes 806f020d 041cffff Failure Predicted on...

Страница 322: ... Yes 806f050c 200cffff Memory Logging Limit Reached for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 12 Yes 806f050c 200dffff Memory Logging Limit Reached for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 13 Yes 806f050c 200effff Memory Logging Limit Reached for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 14 Yes 806f050c 200fffff Memory Logging Li...

Страница 323: ...s failed Drive 1 Yes 806f060d 0402ffff Array ComputerSystemElementName has failed Drive 2 Yes 806f060d 0403ffff Array ComputerSystemElementName has failed Drive 3 Yes 806f060d 0404ffff Array ComputerSystemElementName has failed Drive 4 Yes 806f060d 0405ffff Array ComputerSystemElementName has failed Drive 5 Yes 806f060d 0406ffff Array ComputerSystemElementName has failed Drive 6 Yes 806f060d 0407f...

Страница 324: ...erSystemElementName has failed Drive 24 Yes 806f060d 0419ffff Array ComputerSystemElementName has failed Drive 25 Yes 806f060d 041affff Array ComputerSystemElementName has failed Drive 26 Yes 806f060d 041bffff Array ComputerSystemElementName has failed Drive 27 Yes 806f060d 041cffff Array ComputerSystemElementName has failed Drive 28 Yes 806f060d 041dffff Array ComputerSystemElementName has failed...

Страница 325: ...02 00000000 Certificate Authority arg1 has detected a arg2 Certificate Error This message is for the use case when there is an error with an SSL Server SSL Client or SSL Trusted CA Certificate May also be shown as 4000000200000000 or 0x4000000200000000 Severity Error Serviceable No Automatically notify support No Alert Category System SSL certification SNMP Trap ID 22 CIM Information Prefix IMM ID...

Страница 326: ...s message is for the use case where A user modifies the Ethernet Port duplex setting May also be shown as 4000000400000000 or 0x4000000400000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0004 User Response Information only no action is required 40000005 00000000 Ethernet MTU setting modified from arg1 to arg2 by user...

Страница 327: ...hernet Port MAC address setting May also be shown as 4000000600000000 or 0x4000000600000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0006 User Response Information only no action is required 40000007 00000000 Ethernet interface arg1 by user arg2 This message is for the use case where a user enables or disabled the e...

Страница 328: ...800000000 or 0x4000000800000000 Severity Info Serviceable No Automatically notify support No Alert Category System IMM Network event SNMP Trap ID 37 CIM Information Prefix IMM ID 0008 User Response Information only no action is required 40000009 00000000 IP address of network interface modified from arg1 to arg2 by user arg3 This message is for the use case where user modifies the IP address of a ...

Страница 329: ...also be shown as 4000000a00000000 or 0x4000000a00000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0010 User Response Information only no action is required 4000000b 00000000 IP address of default gateway modified from arg1 to arg2 by user arg3 This message is for the use case where a user modifies the default gateway...

Страница 330: ...00000 or 0x4000000c00000000 Severity Warning Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0012 User Response Information only no action is required 4000000d 00000000 DHCP arg1 failure no IP address assigned This message is for the use case where a DHCP server fails to assign an IP address to a Management Controller May also be shown ...

Страница 331: ...er successfully logs in to a Management Controller May also be shown as 4000000e00000000 or 0x4000000e00000000 Severity Info Serviceable No Automatically notify support No Alert Category System Remote Login SNMP Trap ID 30 CIM Information Prefix IMM ID 0014 User Response Information only no action is required 4000000f 00000000 Attempting to arg1 server arg2 by user arg3 This message is for the use...

Страница 332: ...rviceable No Automatically notify support No Alert Category System Remote Login SNMP Trap ID 30 CIM Information Prefix IMM ID 0016 User Response Complete the following steps until the problem is solved 1 Make sure that the correct login ID and password are being used 2 Have the system administrator reset the login ID or password 40000011 00000000 Security Login ID arg1 had arg2 login failures from...

Страница 333: ... use case where a remote user has failed to establish a remote control session from a Web browser session May also be shown as 4000001200000000 or 0x4000001200000000 Severity Info Serviceable No Automatically notify support No Alert Category System Remote Login SNMP Trap ID 30 CIM Information Prefix IMM ID 0018 User Response Make sure that the correct login ID and password are being used 40000013 ...

Страница 334: ...agement Controller Event Log on a system is cleared by a user May also be shown as 4000001400000000 or 0x4000001400000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0020 User Response Information only no action is required 40000015 00000000 Management Controller arg1 reset was initiated by user arg2 This message is fo...

Страница 335: ... has been assigned by the DHCP server May also be shown as 4000001600000000 or 0x4000001600000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0022 User Response Information only no action is required 40000017 00000000 ENET arg1 IP Cfg HstName arg2 IP arg3 NetMsk arg4 GW arg5 This message is for the use case where a Man...

Страница 336: ...troller ethernet interface is no longer active May also be shown as 4000001800000000 or 0x4000001800000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0024 User Response Information only no action is required 40000019 00000000 LAN Ethernet arg1 interface is now active This message is for the use case where a Management...

Страница 337: ...0000 or 0x4000001a00000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0026 User Response Information only no action is required 4000001b 00000000 Management Controller arg1 Configuration restored from a file by user arg2 This message is for the use case where a user restores a Management Controller configuration from ...

Страница 338: ...Trap ID 22 CIM Information Prefix IMM ID 0028 User Response If there was no operating system error complete the following steps until the problem is solved 1 Reconfigure the watchdog timer to a higher value 2 Make sure that the IMM Ethernet over USB interface is enabled 3 Reinstall the RNDIS or cdc_ether device driver for the operating system 4 Disable the watchdog If there was an operating system...

Страница 339: ...ystem 5 Update the IMM firmware Important Some cluster solutions require specific code levels or coordinated code updates If the device is part of a cluster solution verify that the latest level of code is supported for the cluster solution before you update the code 4000001e 00000000 Running the backup Management Controller arg1 main application This message is for the use case where a Management...

Страница 340: ...cally notify support No Alert Category System other SNMP Trap ID 22 CIM Information Prefix IMM ID 0031 User Response Update the IMM firmware to a version that the server supports Important Some cluster solutions require specific code levels or coordinated code updates If the device is part of a cluster solution verify that the latest level of code is supported for the cluster solution before you u...

Страница 341: ...CIM Information Prefix IMM ID 0033 User Response Information only no action is required 40000022 00000000 SSL data in the Management Controller arg1 configuruation data is invalid Clearing configuration data region and disabling SSL This message is for the use case where a Management Controller has detected invalid SSL data in the configuration data and is clearing the configuration data region an...

Страница 342: ...ement Processor or Remote Expansion Enclosure Processor from the interface and IP address d May also be shown as 4000002300000000 or 0x4000002300000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0035 User Response Information only no action is required 40000024 00000000 Flash of arg1 from arg2 failed for user arg3 Thi...

Страница 343: ...eable No Automatically notify support No Alert Category System Event Log 75 full SNMP Trap ID 35 CIM Information Prefix IMM ID 0037 User Response Information only no action is required 40000026 00000000 The arg1 on system arg2 is 100 full This message is for the use case where a Management Controller Event Log on a system is 100 full May also be shown as 4000002600000000 or 0x4000002600000000 Seve...

Страница 344: ... ID 21 CIM Information Prefix IMM ID 0039 User Response Complete the following steps until the problem is solved 1 Reconfigure the watchdog timer to a higher value 2 Make sure that the IMM Ethernet over USB interface is enabled 3 Reinstall the RNDIS or cdc_ether device driver for the operating system 4 Disable the watchdog 5 Check the integrity of the installed operating system 40000028 00000000 M...

Страница 345: ...utomatically notify support No Alert Category System Remote Login SNMP Trap ID 30 CIM Information Prefix IMM ID 0041 User Response Complete the following steps until the problem is solved 1 Make sure that the correct login ID and password are being used 2 Have the system administrator reset the login ID or password 4000002a 00000000 arg1 firmware mismatch internal to system arg2 Please attempt to ...

Страница 346: ...own as 4000002b00000000 or 0x4000002b00000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0043 User Response Information only no action is required 4000002c 00000000 Domain Source changed to arg1 by user arg2 Domain source changed by user May also be shown as 4000002c00000000 or 0x4000002c00000000 Severity Info Service...

Страница 347: ...x4000002d00000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0045 User Response Information only no action is required 4000002e 00000000 DDNS registration successful The domain name is arg1 DDNS registation and values May also be shown as 4000002e00000000 or 0x4000002e00000000 Severity Info Serviceable No Automaticall...

Страница 348: ...everity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0047 User Response Information only no action is required 40000030 00000000 IPv6 disabled by user arg1 IPv6 protocol is disabled by user May also be shown as 4000003000000000 or 0x4000003000000000 Severity Info Serviceable No Automatically notify support No Alert Category none...

Страница 349: ...ity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0049 User Response Information only no action is required 40000032 00000000 IPv6 DHCP enabled by user arg1 IPv6 DHCP assignment method is enabled by user May also be shown as 4000003200000000 or 0x4000003200000000 Severity Info Serviceable No Automatically notify support No Alert ...

Страница 350: ...ically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0051 User Response Information only no action is required 40000034 00000000 IPv6 static IP configuration disabled by user arg1 IPv6 static assignment method is disabled by user May also be shown as 4000003400000000 or 0x4000003400000000 Severity Info Serviceable No Automatically notify support No Alert Category...

Страница 351: ...ation Prefix IMM ID 0053 User Response Information only no action is required 40000036 00000000 IPv6 stateless auto configuration disabled by user arg1 IPv6 statless auto assignment method is disabled by user May also be shown as 4000003600000000 or 0x4000003600000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0054 Us...

Страница 352: ...rmation only no action is required 40000038 00000000 ENET arg1 IPv6 Static HstName arg2 IP arg3 Pref arg4 GW arg5 IPv6 Static address is active May also be shown as 4000003800000000 or 0x4000003800000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0056 User Response Information only no action is required 40000039 00000...

Страница 353: ...dified from arg1 to arg2 by user arg3 A user modifies the IPv6 static address of a Management Controller May also be shown as 4000003a00000000 or 0x4000003a00000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0058 User Response Information only no action is required 4000003b 00000000 DHCPv6 failure no IP address assign...

Страница 354: ...the IMM 4000003c 00000000 Platform Watchdog Timer expired for arg1 An implementation has detected an OS Loader Watchdog Timer Expired May also be shown as 4000003c00000000 or 0x4000003c00000000 Severity Error Serviceable No Automatically notify support No Alert Category System Loader timeout SNMP Trap ID 26 CIM Information Prefix IMM ID 0060 User Response 1 Reconfigure the watchdog timer to a high...

Страница 355: ...ory none SNMP Trap ID CIM Information Prefix IMM ID 0061 User Response Information only no action is required 4000003e 00000000 SSH port number changed from arg1 to arg2 by user arg3 A user has modified the SSH port number May also be shown as 4000003e00000000 or 0x4000003e00000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix ...

Страница 356: ...n only no action is required 40000040 00000000 Web HTTPS port number changed from arg1 to arg2 by user arg3 A user has modified the Web HTTPS port number May also be shown as 4000004000000000 or 0x4000004000000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0064 User Response Information only no action is required 4000...

Страница 357: ...2 by user arg3 A user has modified the CIM HTTPS port number May also be shown as 4000004200000000 or 0x4000004200000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0066 User Response Information only no action is required 40000043 00000000 SNMP Agent port number changed from arg1 to arg2 by user arg3 A user has modifi...

Страница 358: ...umber May also be shown as 4000004400000000 or 0x4000004400000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0068 User Response Information only no action is required 40000045 00000000 Syslog port number changed from arg1 to arg2 by user arg3 A user has modified the Syslog receiver port number May also be shown as 400...

Страница 359: ...rt number May also be shown as 4000004600000000 or 0x4000004600000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0070 User Response Information only no action is required 40000047 00000000 LED arg1 state changed to arg2 by arg3 A user has modified the state of an LED May also be shown as 4000004700000000 or 0x40000047...

Страница 360: ...inventory to change May also be shown as 4000004800000000 or 0x4000004800000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0072 User Response Information only no action is required 40000049 00000000 SNMP arg1 enabled by user arg2 A user enabled SNMPv1 or SNMPv3 or Traps May also be shown as 4000004900000000 or 0x40000...

Страница 361: ...0000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0074 User Response Information only no action is required 4000004b 00000000 SNMPv1 arg1 set by user arg2 Name arg3 AccessType arg4 Address arg5 A user changed the SNMP community string May also be shown as 4000004b00000000 or 0x4000004b00000000 Severity Info Serviceable ...

Страница 362: ...Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0076 User Response Information only no action is required 4000004d 00000000 LDAP set by user arg1 RootDN arg2 UIDSearchAttribute arg3 BindingMethod arg4 EnhancedRBS arg5 TargetName arg6 GroupFilter arg7 GroupAttribute arg8 LoginAttribute arg9 A user configured an LDAP Miscellaneous se...

Страница 363: ...4e00000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0078 User Response Information only no action is required 4000004f 00000000 Date and Time set by user arg1 Date arg2 Time arg3 DST Auto adjust arg4 Timezone arg5 A user configured the Date and Time settings May also be shown as 4000004f00000000 or 0x4000004f0000000...

Страница 364: ...000 or 0x4000005000000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0080 User Response Information only no action is required 40000051 00000000 Server Power Off Delay set to arg1 by user arg2 A user configured the Server Power Off Delay May also be shown as 4000005100000000 or 0x4000005100000000 Severity Info Service...

Страница 365: ...iceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0082 User Response Information only no action is required 40000053 00000000 Server arg1 scheduled for every arg2 at arg3 by user arg4 A user configured a recurring Server Power Action May also be shown as 4000005300000000 or 0x4000005300000000 Severity Info Serviceable No Automatically notify ...

Страница 366: ... SNMP Trap ID CIM Information Prefix IMM ID 0084 User Response Information only no action is required 40000055 00000000 Synchronize time setting by user arg1 Mode arg2 NTPServerHost arg3 arg4 NTPUpdateFrequency arg5 A user configured the Date and Time synchronize settings May also be shown as 4000005500000000 or 0x4000005500000000 Severity Info Serviceable No Automatically notify support No Alert ...

Страница 367: ...P Trap ID CIM Information Prefix IMM ID 0086 User Response Information only no action is required 40000057 00000000 Telnet arg1 by user arg2 A user enables or disables Telnet services May also be shown as 4000005700000000 or 0x4000005700000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0087 User Response Information o...

Страница 368: ...matically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0088 User Response Information only no action is required 40000059 00000000 LAN over USB arg1 by user arg2 A user configured USB LAN May also be shown as 4000005900000000 or 0x4000005900000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix...

Страница 369: ...90 User Response Information only no action is required 4000005b 00000000 Secure Web services HTTPS arg1 by user arg2 A user enables or disables Secure web services May also be shown as 4000005b00000000 or 0x4000005b00000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0091 User Response Information only no action is re...

Страница 370: ...re LDAP arg1 by user arg2 A user enables or disables Secure LDAP services May also be shown as 4000005d00000000 or 0x4000005d00000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0093 User Response Information only no action is required 4000005e 00000000 SSH arg1 by user arg2 A user enables or disables SSH services May ...

Страница 371: ...oaderTimeout arg5 A user configures Server Timeouts May also be shown as 4000005f00000000 or 0x4000005f00000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0095 User Response Information only no action is required 40000060 00000000 License key for arg1 added by user arg2 A user installs License Key May also be shown as...

Страница 372: ...0x4000006100000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0097 User Response Information only no action is required 40000062 00000000 Global Login General Settings set by user arg1 AuthenticationMethod arg2 LockoutPeriod arg3 SessionTimeout arg4 A user changes the Global Login General Settings May also be shown as...

Страница 373: ...utAfterMaxFailures arg8 MinimumDifferentCharacters arg9 DefaultIDExpired arg10 ChangePasswordFirstAccess arg11 A user changes the Global Login Account Security Settings to Legacy May also be shown as 4000006300000000 or 0x4000006300000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0099 User Response Information only n...

Страница 374: ...ay also be shown as 4000006500000000 or 0x4000006500000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0101 User Response Information only no action is required 40000066 00000000 User arg1 password modified A user account was changed May also be shown as 4000006600000000 or 0x4000006600000000 Severity Info 362 Lenovo S...

Страница 375: ...4000006700000000 or 0x4000006700000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0103 User Response Information only no action is required 40000068 00000000 User arg1 custom privileges set arg2 User account priveleges assigned May also be shown as 4000006800000000 or 0x4000006800000000 Severity Info Serviceable No Ap...

Страница 376: ... May also be shown as 4000006900000000 or 0x4000006900000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0105 User Response Information only no action is required 4000006a 00000000 SSH Client key added for user arg1 User locally defined an SSH Client key May also be shown as 4000006a00000000 or 0x4000006a00000000 Sever...

Страница 377: ...0 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0107 User Response Information only no action is required 4000006c 00000000 SSH Client key removed from user arg1 User removed an SSH Client key May also be shown as 4000006c00000000 or 0x4000006c00000000 Severity Info Serviceable No Automatically notify support No Alert Ca...

Страница 378: ...cally notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0109 User Response Information only no action is required 4000006e 00000000 Alert Configuration Global Event Notification set by user arg1 RetryLimit arg2 RetryInterval arg3 EntryInterval arg4 A user changes the Global Event Notification settings May also be shown as 4000006e00000000 or 0x4000006e00000000 Severi...

Страница 379: ...00 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0111 User Response Information only no action is required 40000070 00000000 SNMP Traps enabled by user arg1 EnabledAlerts arg2 AllowedFilters arg3 A user enabled the SNMP Traps configuration May also be shown as 4000007000000000 or 0x4000007000000000 Severity Info Servicea...

Страница 380: ...port No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0113 User Response Information only no action is required 40000072 00000000 The minimum power cap value changed from arg1 watts to arg2 watts Minimum Power Cap value changed May also be shown as 4000007200000000 or 0x4000007200000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID C...

Страница 381: ...formation Prefix IMM ID 0115 User Response Information only no action is required 40000074 00000000 The soft minimum power cap value changed from arg1 watts to arg2 watts Soft Minimum Power Cap value changed May also be shown as 4000007400000000 or 0x4000007400000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0116 Use...

Страница 382: ...on only no action is required 40000076 00000000 The new minimum power cap value exceeded the power cap value Minimum Power Cap exceeds Power Cap May also be shown as 4000007600000000 or 0x4000007600000000 Severity Warning Serviceable No Automatically notify support No Alert Category Warning Power SNMP Trap ID 164 CIM Information Prefix IMM ID 0118 User Response Information only no action is requir...

Страница 383: ...r arg1 Power capping deactivated by user May also be shown as 4000007800000000 or 0x4000007800000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0120 User Response Information only no action is required 40000079 00000000 Static Power Savings mode has been turned on by user arg1 Static Power Savings mode turned on by us...

Страница 384: ... user May also be shown as 4000007a00000000 or 0x4000007a00000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0122 User Response Information only no action is required 4000007b 00000000 Dynamic Power Savings mode has been turned on by user arg1 Dynamic Power Savings mode turned on by user May also be shown as 4000007b0...

Страница 385: ...May also be shown as 4000007c00000000 or 0x4000007c00000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0124 User Response Information only no action is required 4000007d 00000000 Power cap and external throttling occurred Power cap and external throttling occurred May also be shown as 4000007d00000000 or 0x4000007d000...

Страница 386: ...0000 or 0x4000007e00000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0126 User Response Information only no action is required 4000007f 00000000 Power cap throttling occurred Power cap throttling occurrred May also be shown as 4000007f00000000 or 0x4000007f00000000 Severity Info Serviceable No Automatically notify su...

Страница 387: ...0x4000008000000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0128 User Response Information only no action is required 40000081 00000000 PXE boot requested by user arg1 PXE boot requested May also be shown as 4000008100000000 or 0x4000008100000000 Severity Info Serviceable No Automatically notify support No Alert Cat...

Страница 388: ...cally notify support No Alert Category Warning Power SNMP Trap ID 164 CIM Information Prefix IMM ID 0130 User Response Information only no action is required 40000083 00000000 The new minimum power cap value has returned below the power cap value Minimum Power Cap exceeds Power Cap recovered May also be shown as 4000008300000000 or 0x4000008300000000 Severity Info Serviceable No Automatically noti...

Страница 389: ...support No Alert Category System Other SNMP Trap ID 22 CIM Information Prefix IMM ID 0132 User Response Attempt to flash the IMM firmware to the same level on all nodes 40000085 00000000 FPGA firmware mismatch between nodes arg1 and arg2 Please attempt to flash the FPGA firmware to the same level on all nodes A mismatch of FPGA firmware has been detected between nodes May also be shown as 40000085...

Страница 390: ...le No Automatically notify support Yes Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0134 User Response Information only no action is required 40000087 00000000 Manual Call Home by user arg1 arg2 Manual Call Home by user May also be shown as 4000008700000000 or 0x4000008700000000 Severity Info Serviceable No Automatically notify support Yes Alert Category none SNMP Trap ID CIM Inf...

Страница 391: ...y none SNMP Trap ID CIM Information Prefix IMM ID 0136 User Response Information only no action is required 40000089 00000000 Management Controller arg1 Configuration restoration from a file by user arg2 failed to complete This message is for the use case where a user restores a Management Controller configuration from a file and the restoration fails to complete May also be shown as 4000008900000...

Страница 392: ...0008a00000000 or 0x4000008a00000000 Severity Error Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID 22 CIM Information Prefix IMM ID 0138 User Response 1 Turn off the server and disconnect it from the power source You must disconnect the server from ac power to reset the IMM 2 After 45 seconds reconnect the server to the power source and turn on the server 3 ...

Страница 393: ...erted May also be shown as 800100020701ffff or 0x800100020701ffff Severity Warning Serviceable Yes Automatically notify support No Alert Category Warning Voltage SNMP Trap ID 13 CIM Information Prefix PLAT ID 0476 User Response Replace the system battery 80010202 0701ffff Numeric sensor NumericSensorElementName going low lower critical has asserted This message is for the use case when an implemen...

Страница 394: ...ems 4 Trained technician only Replace the system board n power supply number 80010204 1d01ffff Numeric sensor NumericSensorElementName going low lower critical has asserted Fan 1A 1B Tach This message is for the use case when an implementation has detected a Lower Critical sensor going low has asserted May also be shown as 800102041d01ffff or 0x800102041d01ffff Severity Error Serviceable Yes Autom...

Страница 395: ... User Response 1 Reseat the failing fan n which is indicated by a lit LED near the fan connector on the system board 2 Replace the failing fan n fan number 80010204 1d03ffff Numeric sensor NumericSensorElementName going low lower critical has asserted Fan 3A 3B Tach This message is for the use case when an implementation has detected a Lower Critical sensor going low has asserted May also be shown...

Страница 396: ... Serviceable Yes Automatically notify support No Alert Category Critical Fan Failure SNMP Trap ID 11 CIM Information Prefix PLAT ID 0480 User Response 1 Reseat the failing fan n which is indicated by a lit LED near the fan connector on the system board 2 Replace the failing fan n fan number 80010701 0701ffff Numeric sensor NumericSensorElementName going high upper non critical has asserted ROMB Te...

Страница 397: ...ted Ambient Temp This message is for the use case when an implementation has detected an Upper Non critical sensor going high has asserted May also be shown as 800107010c01ffff or 0x800107010c01ffff Severity Warning Serviceable Yes Automatically notify support No Alert Category Warning Temperature SNMP Trap ID 12 CIM Information Prefix PLAT ID 0490 User Response 1 Make sure the air baffles heat si...

Страница 398: ...ure the node cover is installed and completely closed 2 Make sure the fans are operating and there are no obstructions to the airflow 3 Reduce the Ambient temperature The system must be operating within the specifications see Features and specifications for more information 80010701 1002ffff Numeric sensor NumericSensorElementName going high upper non critical has asserted PCI Riser 2 Temp This me...

Страница 399: ...11003ffff Severity Warning Serviceable Yes Automatically notify support No Alert Category Warning Temperature SNMP Trap ID 12 CIM Information Prefix PLAT ID 0490 User Response 1 Make sure the air baffles heat sink are placed and correctly installed and make sure the node cover is installed and completely closed 2 Make sure the fans are operating and there are no obstructions to the airflow 3 Reduc...

Страница 400: ...stem must be operating within the specifications see Features and specifications for more information 80010701 1402ffff Numeric sensor NumericSensorElementName going high upper non critical has asserted CPU2 VR Temp This message is for the use case when an implementation has detected an Upper Non critical sensor going high has asserted May also be shown as 800107011402ffff or 0x800107011402ffff Se...

Страница 401: ...es Automatically notify support No Alert Category Warning Temperature SNMP Trap ID 12 CIM Information Prefix PLAT ID 0490 User Response 1 Make sure the air baffles heat sink are placed and correctly installed and make sure the node cover is installed and completely closed 2 Make sure the fans are operating and there are no obstructions to the airflow 3 Reduce the Ambient temperature The system mus...

Страница 402: ...sserted DIMM EF VR Temp This message is for the use case when an implementation has detected an Upper Non critical sensor going high has asserted May also be shown as 800107011405ffff or 0x800107011405ffff Severity Warning Serviceable Yes Automatically notify support No Alert Category Warning Temperature SNMP Trap ID 12 CIM Information Prefix PLAT ID 0490 User Response 1 Make sure the air baffles ...

Страница 403: ...re the node cover is installed and completely closed 2 Make sure the fans are operating and there are no obstructions to the airflow 3 Reduce the Ambient temperature The system must be operating within the specifications see Features and specifications for more information 80010701 2c01ffff Numeric sensor NumericSensorElementName going high upper non critical has asserted Mezz Card Temp This messa...

Страница 404: ...x800107012d01ffff Severity Warning Serviceable Yes Automatically notify support No Alert Category Warning Temperature SNMP Trap ID 12 CIM Information Prefix PLAT ID 0490 User Response 1 Make sure the air baffles heat sink are placed and correctly installed and make sure the node cover is installed and completely closed 2 Make sure the fans are operating and there are no obstructions to the airflow...

Страница 405: ...ystem must be operating within the specifications see Features and specifications for more information 80010901 0c01ffff Numeric sensor NumericSensorElementName going high upper critical has asserted Ambient Temp This message is for the use case when an implementation has detected an Upper Critical sensor going high has asserted May also be shown as 800109010c01ffff or 0x800109010c01ffff Severity ...

Страница 406: ...e Yes Automatically notify support No Alert Category Critical Temperature SNMP Trap ID 0 CIM Information Prefix PLAT ID 0494 User Response 1 Make sure the air baffles heat sink are placed and correctly installed and make sure the node cover is installed and completely closed 2 Make sure the fans are operating and there are no obstructions to the airflow 3 Reduce the Ambient temperature The system ...

Страница 407: ...serted Rear BP Temp This message is for the use case when an implementation has detected an Upper Critical sensor going high has asserted May also be shown as 800109011003ffff or 0x800109011003ffff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Temperature SNMP Trap ID 0 CIM Information Prefix PLAT ID 0494 User Response 1 Make sure the air baffles heat sink ...

Страница 408: ...sure the node cover is installed and completely closed 2 Make sure the fans are operating and there are no obstructions to the airflow 3 Reduce the Ambient temperature The system must be operating within the specifications see Features and specifications for more information 80010901 1402ffff Numeric sensor NumericSensorElementName going high upper critical has asserted CPU2 VR Temp This message i...

Страница 409: ...9011403ffff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Temperature SNMP Trap ID 0 CIM Information Prefix PLAT ID 0494 User Response 1 Make sure the air baffles heat sink are placed and correctly installed and make sure the node cover is installed and completely closed 2 Make sure the fans are operating and there are no obstructions to the airflow 3 Reduc...

Страница 410: ...system must be operating within the specifications see Features and specifications for more information 80010901 1405ffff Numeric sensor NumericSensorElementName going high upper critical has asserted DIMM EF VR Temp This message is for the use case when an implementation has detected an Upper Critical sensor going high has asserted May also be shown as 800109011405ffff or 0x800109011405ffff Sever...

Страница 411: ...Yes Automatically notify support No Alert Category Critical Temperature SNMP Trap ID 0 CIM Information Prefix PLAT ID 0494 User Response 1 Make sure the air baffles heat sink are placed and correctly installed and make sure the node cover is installed and completely closed 2 Make sure the fans are operating and there are no obstructions to the airflow 3 Reduce the Ambient temperature The system mu...

Страница 412: ...as asserted PCH Temp This message is for the use case when an implementation has detected an Upper Critical sensor going high has asserted May also be shown as 800109012d01ffff or 0x800109012d01ffff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Temperature SNMP Trap ID 0 CIM Information Prefix PLAT ID 0494 User Response 1 Make sure the air baffles heat sink...

Страница 413: ...he system board If the specified sensor is Planar 12V complete the following steps until the problem is solved 1 Check power supply n LED 2 Remove the failing power supply 3 Trained technician only Replace the system board n power supply number 80010b01 0701ffff Numeric sensor NumericSensorElementName going high upper non recoverable has asserted ROMB Temp This message is for the use case when an ...

Страница 414: ...b010c01ffff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Temperature SNMP Trap ID 0 CIM Information Prefix PLAT ID 0498 User Response 1 Make sure the air baffles heat sink are placed and correctly installed and make sure the node cover is installed and completely closed 2 Make sure the fans are operating and there are no obstructions to the airflow 3 Reduc...

Страница 415: ...t be operating within the specifications see Features and specifications for more information 80010b01 1002ffff Numeric sensor NumericSensorElementName going high upper non recoverable has asserted PCI Riser 2 Temp This message is for the use case when an implementation has detected an Upper Non recoverable sensor going high has asserted May also be shown as 80010b011002ffff or 0x80010b011002ffff ...

Страница 416: ...e Yes Automatically notify support No Alert Category Critical Temperature SNMP Trap ID 0 CIM Information Prefix PLAT ID 0498 User Response 1 Make sure the air baffles heat sink are placed and correctly installed and make sure the node cover is installed and completely closed 2 Make sure the fans are operating and there are no obstructions to the airflow 3 Reduce the Ambient temperature The system ...

Страница 417: ...serted CPU2 VR Temp This message is for the use case when an implementation has detected an Upper Non recoverable sensor going high has asserted May also be shown as 80010b011402ffff or 0x80010b011402ffff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Temperature SNMP Trap ID 0 CIM Information Prefix PLAT ID 0498 User Response 1 Make sure the air baffles hea...

Страница 418: ...sure the node cover is installed and completely closed 2 Make sure the fans are operating and there are no obstructions to the airflow 3 Reduce the Ambient temperature The system must be operating within the specifications see Features and specifications for more information 80010b01 1404ffff Numeric sensor NumericSensorElementName going high upper non recoverable has asserted DIMM CD VR Temp This...

Страница 419: ...b011405ffff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Temperature SNMP Trap ID 0 CIM Information Prefix PLAT ID 0498 User Response 1 Make sure the air baffles heat sink are placed and correctly installed and make sure the node cover is installed and completely closed 2 Make sure the fans are operating and there are no obstructions to the airflow 3 Reduc...

Страница 420: ... must be operating within the specifications see Features and specifications for more information 80010b01 2c01ffff Numeric sensor NumericSensorElementName going high upper non recoverable has asserted Mezz Card Temp This message is for the use case when an implementation has detected an Upper Non recoverable sensor going high has asserted May also be shown as 80010b012c01ffff or 0x80010b012c01fff...

Страница 421: ...01ffff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Temperature SNMP Trap ID 0 CIM Information Prefix PLAT ID 0498 User Response 1 Make sure the air baffles heat sink are placed and correctly installed and make sure the node cover is installed and completely closed 2 Make sure the fans are operating and there are no obstructions to the airflow 3 Reduce the...

Страница 422: ...01ffff or 0x800300122301ffff Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0509 User Response No action information only 80030108 1301ffff Sensor SensorElementName has asserted PS Heavy Load This message is for the use case when an implementation has detected a Sensor has asserted May also be shown as 8003010813...

Страница 423: ...o be shown as 800701010c01ffff or 0x800701010c01ffff Severity Warning Serviceable Yes Automatically notify support No Alert Category Warning Temperature SNMP Trap ID 12 CIM Information Prefix PLAT ID 0520 User Response 1 Check the microprocessor installed is Intel E5 2690 2 Reduce the ambient temperature under 27 Celsius degree 8007010f 2201ffff Sensor SensorElementName has transitioned from norma...

Страница 424: ...om normal to non critical state I O Resources This message is for the use case when an implementation has detected a Sensor transitioned to non critical from normal May also be shown as 8007010f2582ffff or 0x8007010f2582ffff Severity Warning Serviceable Yes Automatically notify support No Alert Category Warning Other SNMP Trap ID 60 CIM Information Prefix PLAT ID 0520 User Response Complete the fo...

Страница 425: ... tasks that require the TPM physical presence switch to be in the ON position 2 Restore the physical presence switch to the OFF position 3 Reboot the system 4 Trained technician only If the error continues replace the planar 80070201 0301ffff Sensor SensorElementName has transitioned to critical from a less severe state CPU 1 OverTemp This message is for the use case when an implementation has det...

Страница 426: ...is for the use case when an implementation has detected a Sensor transitioned to critical from less severe May also be shown as 800702010302ffff or 0x800702010302ffff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Temperature SNMP Trap ID 0 CIM Information Prefix PLAT ID 0522 User Response 1 Make sure that the fans are operating that there are no obstruction...

Страница 427: ...4 Check for a server firmware update Important Some cluster solutions require specific code levels or coordinated code updates If the device is part of a cluster solution verify that the latest level of code is supported for the cluster solution before you update the code 5 Trained technician only Replace the system board 80070204 0a01ffff Sensor SensorElementName has transitioned to critical from...

Страница 428: ...0a02ffff or 0x800702040a02ffff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Fan Failure SNMP Trap ID 11 CIM Information Prefix PLAT ID 0522 User Response 1 Make sure that there are no obstructions such as bundled cables to the airflow from the power supply fan 2 Replace power supply n n power supply number 80070208 0a01ffff Sensor SensorElementName has tra...

Страница 429: ...nfig html 3 Replace power supply n n power supply number 80070208 0a02ffff Sensor SensorElementName has transitioned to critical from a less severe state PS 2 Therm Fault This message is for the use case when an implementation has detected a Sensor transitioned to critical from less severe May also be shown as 800702080a02ffff or 0x800702080a02ffff Severity Error Serviceable Yes Automatically noti...

Страница 430: ...less severe May also be shown as 8007020c2502ffff or 0x8007020c2502ffff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Other SNMP Trap ID 50 CIM Information Prefix PLAT ID 0522 User Response None 8007020c 2505ffff Sensor SensorElementName has transitioned to critical from a less severe state nvDIMM 05 Status This message is for the use case when an implement...

Страница 431: ...utomatically notify support No Alert Category Critical Other SNMP Trap ID 50 CIM Information Prefix PLAT ID 0522 User Response None 8007020c 250bffff Sensor SensorElementName has transitioned to critical from a less severe state nvDIMM 11 Status This message is for the use case when an implementation has detected a Sensor transitioned to critical from less severe May also be shown as 8007020c250bf...

Страница 432: ...CIM Information Prefix PLAT ID 0522 User Response 1 If enabling TXT is not required disable TXT from the Setup Utility 2 If enabling TXT is required verify that the TPM is enabled and activated from the Setup Utility 3 If the problem remains contact your service representative nvDIMM Flash 8007020f 2582ffff Sensor SensorElementName has transitioned to critical from a less severe state I O Resource...

Страница 433: ... detected a Sensor transitioned to critical from less severe May also be shown as 800702142201ffff or 0x800702142201ffff Severity Error Serviceable No Automatically notify support No Alert Category Critical Other SNMP Trap ID CIM Information Prefix PLAT ID 0522 User Response 1 Update the server firmware see Recovering the server firmware 2 If the problem persists trained technician only replace th...

Страница 434: ...or coordinated code updates If the device is part of a cluster solution verify that the latest level of code is supported for the cluster solution before you update the code 4 Replace any failing device 5 Trained technician only Replace the system board 8007021b 0301ffff Sensor SensorElementName has transitioned to critical from a less severe state CPU 1 QPILinkErr This message is for the use case...

Страница 435: ...fff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Other SNMP Trap ID 50 CIM Information Prefix PLAT ID 0522 User Response 1 Check for a server firmware update 2 Make sure that the installed microprocessors are compatible 3 Trained technician only Replace microprocessor 2 80070301 0301ffff Sensor SensorElementName has transitioned to non recoverable from a l...

Страница 436: ...specifications for more information 3 Make sure that the heat sink for microprocessor n 4 Trained technician only Replace microprocessor n n microprocessor number 80070301 0302ffff Sensor SensorElementName has transitioned to non recoverable from a less severe state CPU 2 OverTemp This message is for the use case when an implementation has detected a Sensor transitioned to non recoverable from les...

Страница 437: ...for the use case when an implementation has detected a Sensor transitioned to non recoverable May also be shown as 800706030701ffff or 0x800706030701ffff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Power SNMP Trap ID 4 CIM Information Prefix PLAT ID 0530 User Response If the specified sensor is one of the Pwr Rail A H Fault please follow actions in Power ...

Страница 438: ...ified sensor is PS n 12V UV Fault complete the following steps until the problem is solved 1 Check power supply n LED 2 Remove the failing power supply 3 Follow actions in Power Problems and Solving Power Problems 4 Trained technician only Replace the system board n power supply number If the specified sensor is PS n 12Vaux Fault complete the following steps until the problem is solved 1 Check pow...

Страница 439: ... actions in Power Problems and Solving Power Problems 4 Trained technician only Replace the system board n power supply number If the specified sensor is PS n 12Vaux Fault complete the following steps until the problem is solved 1 Check power supply n LED 2 Replace power supply n n power supply number 80070614 2201ffff Sensor SensorElementName has transitioned to non recoverable TPM Phy Pres Set T...

Страница 440: ...se No action information only 80080128 2101ffff Device LogicalDeviceElementName has been added Low Security Jmp This message is for the use case when an implementation has detected a Device was inserted May also be shown as 800801282101ffff or 0x800801282101ffff Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0536...

Страница 441: ...on only 800b0108 1301ffff Redundancy Lost for RedundancySetElementName has asserted Power Unit This message is for the use case when Redundancy Lost has asserted May also be shown as 800b01081301ffff or 0x800b01081301ffff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Redundant Power Supply SNMP Trap ID 9 CIM Information Prefix PLAT ID 0802 User Response 1 C...

Страница 442: ...e connectors on fan n are not damaged 2 Make sure that the fan n connectors on the system board are not damaged 3 Make sure that the fans are correctly installed 4 Reseat the fans 5 Replace the fans n fan number 800b010a 1e82ffff Redundancy Lost for RedundancySetElementName has asserted Fan Zone 2 This message is for the use case when Redundancy Lost has asserted May also be shown as 800b010a1e82f...

Страница 443: ...viceable Yes Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0802 User Response 1 Check the system event log for DIMM failure events uncorrectable or PFA and correct the failures 2 Re enable mirroring in the Setup utility 800b0309 1301ffff Non redundant Sufficient Resources from Redundancy Degraded or Fully Redundant for RedundancySetEl...

Страница 444: ...graded or Fully Redundant for RedundancySetElementName has asserted Backup Memory This message is for the use case when a Redundancy Set has transitioned from Redundancy Degraded or Fully Redundant to Non redundant Sufficient May also be shown as 800b030c2581ffff or 0x800b030c2581ffff Severity Warning Serviceable Yes Automatically notify support No Alert Category Warning Memory SNMP Trap ID 43 CIM...

Страница 445: ...may happen anyway if the power load is too great 2 Reduce the total power consumption by removing newly added or unused options like drives or adaptors 3 Use the IBM Power Configurator utility to determine current system power consumption For more information and to download the utility go to http www 03 ibm com systems bladecenter resources powerconfig html 4 Replace the power supply with higher ...

Страница 446: ...Zone 2 This message is for the use case when a Redundancy Set has transitioned to Non redundant Insufficient Resources May also be shown as 800b050a1e82ffff or 0x800b050a1e82ffff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Fan Failure SNMP Trap ID 11 CIM Information Prefix PLAT ID 0810 User Response 1 Make sure that the connectors on fan n are not damaged...

Страница 447: ...refix PLAT ID 0810 User Response 1 Check the system event log for DIMM failure events uncorrectable or PFA and correct the failures 2 Re enable mirroring in the Setup utility 806f0007 0301ffff ProcessorElementName has Failed with IERR CPU 1 This message is for the use case when an implementation has detected a Processor Failed IERR Condition May also be shown as 806f00070301ffff or 0x806f00070301f...

Страница 448: ...tation has detected a Processor Failed IERR Condition May also be shown as 806f00070302ffff or 0x806f00070302ffff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical CPU SNMP Trap ID 40 CIM Information Prefix PLAT ID 0042 User Response 1 Make sure that the latest level of firmware and device drivers are installed for all adapters and standard devices such as Ethe...

Страница 449: ...mation Prefix PLAT ID 0084 User Response No action information only 806f0008 0a02ffff PowerSupplyElementName has been added to container PhysicalPackageElementName Power Supply 2 This message is for the use case when an implementation has detected a Power Supply has been added May also be shown as 806f00080a02ffff or 0x806f00080a02ffff Severity Info Serviceable No Automatically notify support No A...

Страница 450: ...sponse No action information only 806f000d 0400ffff The Drive StorageVolumeElementName has been added Drive 0 This message is for the use case when an implementation has detected a Drive has been Added May also be shown as 806f000d0400ffff or 0x806f000d0400ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix...

Страница 451: ...sage is for the use case when an implementation has detected a Drive has been Added May also be shown as 806f000d0402ffff or 0x806f000d0402ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0162 User Response No action information only 806f000d 0403ffff The Drive StorageVolumeElementName has been a...

Страница 452: ...Added May also be shown as 806f000d0404ffff or 0x806f000d0404ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0162 User Response No action information only 806f000d 0405ffff The Drive StorageVolumeElementName has been added Drive 5 This message is for the use case when an implementation has detec...

Страница 453: ...e shown as 806f000d0406ffff or 0x806f000d0406ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0162 User Response No action information only 806f000d 0407ffff The Drive StorageVolumeElementName has been added Drive 7 This message is for the use case when an implementation has detected a Drive has ...

Страница 454: ...08ffff or 0x806f000d0408ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0162 User Response No action information only 806f000d 0409ffff The Drive StorageVolumeElementName has been added Drive 9 This message is for the use case when an implementation has detected a Drive has been Added May also b...

Страница 455: ... Severity Info Serviceable No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0162 User Response No action information only 806f000d 040bffff The Drive StorageVolumeElementName has been added Drive 11 This message is for the use case when an implementation has detected a Drive has been Added May also be shown as 806f000d040bffff...

Страница 456: ...e No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0162 User Response No action information only 806f000d 040dffff The Drive StorageVolumeElementName has been added Drive 13 This message is for the use case when an implementation has detected a Drive has been Added May also be shown as 806f000d040dffff or 0x806f000d040dffff Se...

Страница 457: ...rt No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0162 User Response No action information only 806f000d 040fffff The Drive StorageVolumeElementName has been added Drive 15 This message is for the use case when an implementation has detected a Drive has been Added May also be shown as 806f000d040fffff or 0x806f000d040fffff Severity Info Serviceable No Auto...

Страница 458: ...itical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0162 User Response No action information only 806f000d 0411ffff The Drive StorageVolumeElementName has been added Drive 17 This message is for the use case when an implementation has detected a Drive has been Added May also be shown as 806f000d0411ffff or 0x806f000d0411ffff Severity Info Serviceable No Automatically notify suppor...

Страница 459: ...D 5 CIM Information Prefix PLAT ID 0162 User Response No action information only 806f000d 0413ffff The Drive StorageVolumeElementName has been added Drive 19 This message is for the use case when an implementation has detected a Drive has been Added May also be shown as 806f000d0413ffff or 0x806f000d0413ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Hard ...

Страница 460: ...ponse No action information only 806f000d 0415ffff The Drive StorageVolumeElementName has been added Drive 21 This message is for the use case when an implementation has detected a Drive has been Added May also be shown as 806f000d0415ffff or 0x806f000d0415ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix...

Страница 461: ...sage is for the use case when an implementation has detected a Drive has been Added May also be shown as 806f000d0417ffff or 0x806f000d0417ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0162 User Response No action information only 806f000d 0418ffff The Drive StorageVolumeElementName has been a...

Страница 462: ...Added May also be shown as 806f000d0419ffff or 0x806f000d0419ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0162 User Response No action information only 806f000d 041affff The Drive StorageVolumeElementName has been added Drive 26 This message is for the use case when an implementation has dete...

Страница 463: ...e shown as 806f000d041bffff or 0x806f000d041bffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0162 User Response No action information only 806f000d 041cffff The Drive StorageVolumeElementName has been added Drive 28 This message is for the use case when an implementation has detected a Drive has...

Страница 464: ...1dffff or 0x806f000d041dffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0162 User Response No action information only 806f000d 041effff The Drive StorageVolumeElementName has been added Drive 30 This message is for the use case when an implementation has detected a Drive has been Added May also ...

Страница 465: ...Serviceable No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0162 User Response No action information only 806f000f 220101ff The System ComputerSystemElementName has detected no memory in the system ABR Status This message is for the use case when an implementation has detected that memory was detected in the system May also b...

Страница 466: ...n only replace the system board Firmware Error Sys Boot Status 806f000f 220102ff Subsystem MemoryElementName has insufficient memory for operation ABR Status This message is for the use case when an implementation has detected that the usable Memory is insufficient for operation May also be shown as 806f000f220102ff or 0x806f000f220102ff Severity Error Serviceable Yes Automatically notify support ...

Страница 467: ...T ID 0770 User Response This is a UEFI detected event The UEFI POST error code for this event can be found in the logged IMM message text Please refer to the UEFI POST error code in the UEFI POST error code section of the Information Center for the appropriate user response Firmware Error Sys Boot Status 806f000f 220104ff The System ComputerSystemElementName has encountered a motherboard failure A...

Страница 468: ...rror Serviceable Yes Automatically notify support No Alert Category Critical Other SNMP Trap ID 50 CIM Information Prefix PLAT ID 0764 User Response This is a UEFI detected event The UEFI POST error code for this event can be found in the logged IMM message text Please refer to the UEFI POST error code in the UEFI POST error code section of the Information Center for the appropriate user response ...

Страница 469: ...Alert Category Critical Other SNMP Trap ID 40 CIM Information Prefix PLAT ID 0850 User Response 1 Make sure the server meets the minimum configuration to start see Power supply LEDs 2 Recover the server firmware from the backup page a Restart the server b At the prompt press F3 to recover the firmware 3 Update the server firmware to the latest level see Updating the firmware Important Some cluster...

Страница 470: ... for this event can be found in the logged IMM message text Please refer to the UEFI POST error code in the UEFI POST error code section of the Info Center for the appropriate user response Firmware Error Sys Boot Status 806f000f 2201ffff The System ComputerSystemElementName encountered a POST Error ABR Status This message is for the use case when an implementation has detected a Post Error May al...

Страница 471: ...viceable Yes Automatically notify support No Alert Category Critical Other SNMP Trap ID 50 CIM Information Prefix PLAT ID 0222 User Response If the NMI button has not been pressed complete the following steps 1 Make sure that the NMI button is not pressed 2 Replace the operator information panel cable 3 Replace the operator information panel 806f0021 2201ffff Fault in slot PhysicalConnectorSystemE...

Страница 472: ...omputerSystemElementName All PCI Error This message is for the use case when an implementation has detected a Fault in a slot May also be shown as 806f00212582ffff or 0x806f00212582ffff Severity Error Serviceable Yes Automatically notify support Yes Alert Category Critical Other SNMP Trap ID 50 CIM Information Prefix PLAT ID 0330 User Response 1 Check the PCI LED 2 Reseat the affected adapters and...

Страница 473: ...te the server firmware UEFI and IMM and adapter firmware Important Some cluster solutions require specific code levels or coordinated code updates If the device is part of a cluster solution verify that the latest level of code is supported for the cluster solution before you update the code 4 Remove both adapters 5 Replace the riser card 6 Trained service technicians only Replace the system board...

Страница 474: ... Replace the riser card 6 Trained service technicians only Replace the system board PCI 2 PCI 3 PCI 4 PCI 5 PCI 6 806f0023 2101ffff Watchdog Timer expired for WatchdogElementName IPMI Watchdog This message is for the use case when an implementation has detected a Watchdog Timer Expired May also be shown as 806f00232101ffff or 0x806f00232101ffff Severity Info Serviceable No Automatically notify sup...

Страница 475: ...and restart the server 2 If the problem remains trained technician only replace the system board 806f0107 0301ffff An Over Temperature Condition has been detected on ProcessorElementName CPU 1 This message is for the use case when an implementation has detected an Over Temperature Condition Detected for Processor May also be shown as 806f01070301ffff or 0x806f01070301ffff Severity Error Serviceabl...

Страница 476: ...806f01070302ffff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Temperature SNMP Trap ID 0 CIM Information Prefix PLAT ID 0036 User Response 1 Make sure the air baffles heat sink are placed and correctly installed and make sure the node cover is installed and completely closed 2 Make sure the fans are operating and there are no obstructions to the airflow 3 ...

Страница 477: ... n power supply number 806f0108 0a02ffff PowerSupplyElementName has Failed Power Supply 2 This message is for the use case when an implementation has detected a Power Supply has failed May also be shown as 806f01080a02ffff or 0x806f01080a02ffff Severity Error Serviceable Yes Automatically notify support Yes Alert Category Critical Power SNMP Trap ID 4 CIM Information Prefix PLAT ID 0086 User Respo...

Страница 478: ...y notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0108 User Response No action information only 806f010c 2001ffff Uncorrectable error detected for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 1 This message is for the use case when an implementation has detected a Memory uncorrectable error May also be shown as 806f010c2001ffff or 0x806f01...

Страница 479: ...nd restart the server 8 Trained Service technician only Replace the affected microprocessor 806f010c 2002ffff Uncorrectable error detected for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 2 This message is for the use case when an implementation has detected a Memory uncorrectable error May also be shown as 806f010c2002ffff or 0x806f010c2002ffff Severity Error Serviceable Yes Auto...

Страница 480: ...nformation Prefix PLAT ID 0138 User Response 1 Check the IBM support website for an applicable retain tip or firmware update that applies to this memory error 2 Swap the affected DIMMs as indicated by the error LEDs on the system board or the event logs to a different memory channel or microprocessor 3 If the problem follows the DIMM replace the failing DIMM 4 Trained technician only Remove the af...

Страница 481: ... only Remove the affected microprocessor and check the microprocessor socket pins for any damaged pins If a damage is found replace the system board 5 Trained technician only If the problem occurs on the same DIMM connector check the DIMM connector If the connector contains any foreign material or is damaged replace the system board 6 Trained technician only Replace the affected microprocessor 7 M...

Страница 482: ...on the same DIMM connector check the DIMM connector If the connector contains any foreign material or is damaged replace the system board 6 Trained technician only Replace the affected microprocessor 7 Manually re enable all affected DIMMs Update firmware version to the latest level and reconnect to server to the power source and restart the server 8 Trained Service technician only Replace the aff...

Страница 483: ...DIMMs Update firmware version to the latest level and reconnect to server to the power source and restart the server 8 Trained Service technician only Replace the affected microprocessor 806f010c 2007ffff Uncorrectable error detected for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 7 This message is for the use case when an implementation has detected a Memory uncorrectable error ...

Страница 484: ...Automatically notify support Yes Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0138 User Response 1 Check the IBM support website for an applicable retain tip or firmware update that applies to this memory error 2 Swap the affected DIMMs as indicated by the error LEDs on the system board or the event logs to a different memory channel or microprocessor 3 If the prob...

Страница 485: ... only Remove the affected microprocessor and check the microprocessor socket pins for any damaged pins If a damage is found replace the system board 5 Trained technician only If the problem occurs on the same DIMM connector check the DIMM connector If the connector contains any foreign material or is damaged replace the system board 6 Trained technician only Replace the affected microprocessor 7 M...

Страница 486: ...n the same DIMM connector check the DIMM connector If the connector contains any foreign material or is damaged replace the system board 6 Trained technician only Replace the affected microprocessor 7 Manually re enable all affected DIMMs Update firmware version to the latest level and reconnect to server to the power source and restart the server 8 Trained Service technician only Replace the affe...

Страница 487: ...IMMs Update firmware version to the latest level and reconnect to server to the power source and restart the server 8 Trained Service technician only Replace the affected microprocessor 806f010c 200cffff Uncorrectable error detected for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 12 This message is for the use case when an implementation has detected a Memory uncorrectable error ...

Страница 488: ...Automatically notify support Yes Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0138 User Response 1 Check the IBM support website for an applicable retain tip or firmware update that applies to this memory error 2 Swap the affected DIMMs as indicated by the error LEDs on the system board or the event logs to a different memory channel or microprocessor 3 If the prob...

Страница 489: ... only Remove the affected microprocessor and check the microprocessor socket pins for any damaged pins If a damage is found replace the system board 5 Trained technician only If the problem occurs on the same DIMM connector check the DIMM connector If the connector contains any foreign material or is damaged replace the system board 6 Trained technician only Replace the affected microprocessor 7 M...

Страница 490: ...n the same DIMM connector check the DIMM connector If the connector contains any foreign material or is damaged replace the system board 6 Trained technician only Replace the affected microprocessor 7 Manually re enable all affected DIMMs Update firmware version to the latest level and reconnect to server to the power source and restart the server 8 Trained Service technician only Replace the affe...

Страница 491: ...IMMs Update firmware version to the latest level and reconnect to server to the power source and restart the server 8 Trained Service technician only Replace the affected microprocessor 806f010c 2011ffff Uncorrectable error detected for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 17 This message is for the use case when an implementation has detected a Memory uncorrectable error ...

Страница 492: ...Automatically notify support Yes Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0138 User Response 1 Check the IBM support website for an applicable retain tip or firmware update that applies to this memory error 2 Swap the affected DIMMs as indicated by the error LEDs on the system board or the event logs to a different memory channel or microprocessor 3 If the prob...

Страница 493: ... only Remove the affected microprocessor and check the microprocessor socket pins for any damaged pins If a damage is found replace the system board 5 Trained technician only If the problem occurs on the same DIMM connector check the DIMM connector If the connector contains any foreign material or is damaged replace the system board 6 Trained technician only Replace the affected microprocessor 7 M...

Страница 494: ...n the same DIMM connector check the DIMM connector If the connector contains any foreign material or is damaged replace the system board 6 Trained technician only Replace the affected microprocessor 7 Manually re enable all affected DIMMs Update firmware version to the latest level and reconnect to server to the power source and restart the server 8 Trained Service technician only Replace the affe...

Страница 495: ...IMMs Update firmware version to the latest level and reconnect to server to the power source and restart the server 8 Trained Service technician only Replace the affected microprocessor 806f010c 2016ffff Uncorrectable error detected for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 22 This message is for the use case when an implementation has detected a Memory uncorrectable error ...

Страница 496: ...Automatically notify support Yes Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0138 User Response 1 Check the IBM support website for an applicable retain tip or firmware update that applies to this memory error 2 Swap the affected DIMMs as indicated by the error LEDs on the system board or the event logs to a different memory channel or microprocessor 3 If the prob...

Страница 497: ...only Remove the affected microprocessor and check the microprocessor socket pins for any damaged pins If a damage is found replace the system board 5 Trained technician only If the problem occurs on the same DIMM connector check the DIMM connector If the connector contains any foreign material or is damaged replace the system board 6 Trained technician only Replace the affected microprocessor 7 Ma...

Страница 498: ...n the same DIMM connector check the DIMM connector If the connector contains any foreign material or is damaged replace the system board 6 Trained technician only Replace the affected microprocessor 7 Manually re enable all affected DIMMs Update firmware version to the latest level and reconnect to server to the power source and restart the server 8 Trained Service technician only Replace the affe...

Страница 499: ...Severity Error Serviceable Yes Automatically notify support Yes Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0164 User Response 1 Run the hard disk drive diagnostic test on drive n 2 Reseat the following components a Hard disk drive wait 1 minute or more before reinstalling the drive b Cable from the system board to the backplane 3 Replace the following com...

Страница 500: ... disk drive backplane n hard disk drive number 806f010d 0403ffff The Drive StorageVolumeElementName has been disabled due to a detected fault Drive 3 This message is for the use case when an implementation has detected a Drive was Disabled due to fault May also be shown as 806f010d0403ffff or 0x806f010d0403ffff Severity Error Serviceable Yes Automatically notify support Yes Alert Category Critical...

Страница 501: ...164 User Response 1 Run the hard disk drive diagnostic test on drive n 2 Reseat the following components a Hard disk drive wait 1 minute or more before reinstalling the drive b Cable from the system board to the backplane 3 Replace the following components one at a time in the order shown restarting the server each time a Hard disk drive b Cable from the system board to the backplane c Hard disk d...

Страница 502: ... Drive 6 This message is for the use case when an implementation has detected a Drive was Disabled due to fault May also be shown as 806f010d0406ffff or 0x806f010d0406ffff Severity Error Serviceable Yes Automatically notify support Yes Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0164 User Response 1 Run the hard disk drive diagnostic test on drive n 2 Rese...

Страница 503: ... or more before reinstalling the drive b Cable from the system board to the backplane 3 Replace the following components one at a time in the order shown restarting the server each time a Hard disk drive b Cable from the system board to the backplane c Hard disk drive backplane n hard disk drive number 806f010d 0408ffff The Drive StorageVolumeElementName has been disabled due to a detected fault D...

Страница 504: ...0d0409ffff Severity Error Serviceable Yes Automatically notify support Yes Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0164 User Response 1 Run the hard disk drive diagnostic test on drive n 2 Reseat the following components a Hard disk drive wait 1 minute or more before reinstalling the drive b Cable from the system board to the backplane 3 Replace the fo...

Страница 505: ... a Hard disk drive b Cable from the system board to the backplane c Hard disk drive backplane n hard disk drive number 806f010d 040bffff The Drive StorageVolumeElementName has been disabled due to a detected fault Drive 11 This message is for the use case when an implementation has detected a Drive was Disabled due to fault May also be shown as 806f010d040bffff or 0x806f010d040bffff Severity Error...

Страница 506: ...ort Yes Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0164 User Response 1 Run the hard disk drive diagnostic test on drive n 2 Reseat the following components a Hard disk drive wait 1 minute or more before reinstalling the drive b Cable from the system board to the backplane 3 Replace the following components one at a time in the order shown restarting the ...

Страница 507: ...etected fault Drive 14 This message is for the use case when an implementation has detected a Drive was Disabled due to fault May also be shown as 806f010d040effff or 0x806f010d040effff Severity Error Serviceable Yes Automatically notify support Yes Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0164 User Response 1 Run the hard disk drive diagnostic test on ...

Страница 508: ...ute or more before reinstalling the drive b Cable from the system board to the backplane 3 Replace the following components one at a time in the order shown restarting the server each time a Hard disk drive b Cable from the system board to the backplane c Hard disk drive backplane n hard disk drive number 806f010d 0410ffff The Drive StorageVolumeElementName has been disabled due to a detected faul...

Страница 509: ...411ffff Severity Error Serviceable Yes Automatically notify support Yes Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0164 User Response 1 Run the hard disk drive diagnostic test on drive n 2 Reseat the following components a Hard disk drive wait 1 minute or more before reinstalling the drive b Cable from the system board to the backplane 3 Replace the follo...

Страница 510: ...ime a Hard disk drive b Cable from the system board to the backplane c Hard disk drive backplane n hard disk drive number 806f010d 0413ffff The Drive StorageVolumeElementName has been disabled due to a detected fault Drive 19 This message is for the use case when an implementation has detected a Drive was Disabled due to fault May also be shown as 806f010d0413ffff or 0x806f010d0413ffff Severity Er...

Страница 511: ... Yes Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0164 User Response 1 Run the hard disk drive diagnostic test on drive n 2 Reseat the following components a Hard disk drive wait 1 minute or more before reinstalling the drive b Cable from the system board to the backplane 3 Replace the following components one at a time in the order shown restarting the ser...

Страница 512: ...a detected fault Drive 22 This message is for the use case when an implementation has detected a Drive was Disabled due to fault May also be shown as 806f010d0416ffff or 0x806f010d0416ffff Severity Error Serviceable Yes Automatically notify support Yes Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0164 User Response 1 Run the hard disk drive diagnostic test ...

Страница 513: ... or more before reinstalling the drive b Cable from the system board to the backplane 3 Replace the following components one at a time in the order shown restarting the server each time a Hard disk drive b Cable from the system board to the backplane c Hard disk drive backplane n hard disk drive number 806f010d 0418ffff The Drive StorageVolumeElementName has been disabled due to a detected fault D...

Страница 514: ...0d0419ffff Severity Error Serviceable Yes Automatically notify support Yes Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0164 User Response 1 Run the hard disk drive diagnostic test on drive n 2 Reseat the following components a Hard disk drive wait 1 minute or more before reinstalling the drive b Cable from the system board to the backplane 3 Replace the fo...

Страница 515: ... a Hard disk drive b Cable from the system board to the backplane c Hard disk drive backplane n hard disk drive number 806f010d 041bffff The Drive StorageVolumeElementName has been disabled due to a detected fault Drive 27 This message is for the use case when an implementation has detected a Drive was Disabled due to fault May also be shown as 806f010d041bffff or 0x806f010d041bffff Severity Error...

Страница 516: ...ort Yes Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0164 User Response 1 Run the hard disk drive diagnostic test on drive n 2 Reseat the following components a Hard disk drive wait 1 minute or more before reinstalling the drive b Cable from the system board to the backplane 3 Replace the following components one at a time in the order shown restarting the ...

Страница 517: ...etected fault Drive 30 This message is for the use case when an implementation has detected a Drive was Disabled due to fault May also be shown as 806f010d041effff or 0x806f010d041effff Severity Error Serviceable Yes Automatically notify support Yes Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0164 User Response 1 Run the hard disk drive diagnostic test on ...

Страница 518: ... wait 1 minute or more before reinstalling the drive b Cable from the system board to the backplane 3 Replace the following components one at a time in the order shown restarting the server each time a Hard disk drive b Cable from the system board to the backplane c Hard disk drive backplane n hard disk drive number 806f010f 2201ffff The System ComputerSystemElementName encountered a firmware hang...

Страница 519: ...I This message is for the use case when an implementation has detected a Bus Timeout May also be shown as 806f01130301ffff or 0x806f01130301ffff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Other SNMP Trap ID 50 CIM Information Prefix PLAT ID 0224 User Response 1 Reseat the microprocessor and then restart the server 2 Trained technician only Replace microp...

Страница 520: ...b0701ffff Severity Error Serviceable Yes Automatically notify support Yes Alert Category Critical Other SNMP Trap ID 50 CIM Information Prefix PLAT ID 0266 User Response If the specified sensor is front USB connector reset the front USB cable on the system board If the specified sensor is front video connector reset the front video cable in the system board If the specified sensor is PwrPaddle cab...

Страница 521: ...eset the front video cable in the system board If the specified sensor is PwrPaddle cable complete the following steps until problem is solved 1 Reseat the power paddle cable on the system board 2 Replace the power paddle cable 3 Trained technician only Replace the supercap n n supercap number 4 Trained technician only Replace the system board 806f011b 2505ffff The connector PhysicalConnectorEleme...

Страница 522: ... detected an Interconnect Configuration Error May also be shown as 806f011b2508ffff or 0x806f011b2508ffff Severity Error Serviceable Yes Automatically notify support Yes Alert Category Critical Other SNMP Trap ID 50 CIM Information Prefix PLAT ID 0266 User Response If the specified sensor is front USB connector reset the front USB cable on the system board If the specified sensor is front video co...

Страница 523: ...ensor is PwrPaddle cable complete the following steps until problem is solved 1 Reseat the power paddle cable on the system board 2 Replace the power paddle cable 3 Trained technician only Replace the supercap n n supercap number 4 Trained technician only Replace the system board 806f0123 2101ffff Reboot of system ComputerSystemElementName initiated by WatchdogElementName IPMI Watchdog This messag...

Страница 524: ...rt Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0392 User Response No action information only 806f0125 1001ffff ManagedElementName detected as absent PCI Riser 1 This message is for the use case when an implementation has detected a Managed Element is Absent May also be shown as 806f01251001ffff or 0x806f01251001ffff Severity Info Serviceable No Automatically notify support No...

Страница 525: ...p ID CIM Information Prefix PLAT ID 0392 User Response No action information only 806f0125 2c01ffff ManagedElementName detected as absent Mezz Card This message is for the use case when an implementation has detected a Managed Element is Absent May also be shown as 806f01252c01ffff or 0x806f01252c01ffff Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP T...

Страница 526: ...els or coordinated code updates If the device is part of a cluster solution verify that the latest level of code is supported for the cluster solution before you update the code 2 Update the firmware UEFI and IMM to the latest level Updating the firmware 3 Run the DSA program 4 Reseat the adapter 5 Replace the adapter 6 Trained technician only Replace microprocessor n 7 Trained technician only Rep...

Страница 527: ...lace the system board n microprocessor number 806f0207 2584ffff ProcessorElementName has Failed with FRB1 BIST condition All CPUs This message is for the use case when an implementation has detected a Processor Failed FRB1 BIST condition May also be shown as 806f02072584ffff or 0x806f02072584ffff Severity Error Serviceable Yes Automatically notify support Yes Alert Category Critical CPU SNMP Trap ...

Страница 528: ...egory System Predicted Failure SNMP Trap ID 27 CIM Information Prefix PLAT ID 0168 User Response 1 Run the hard disk drive diagnostic test on drive n 2 Reseat the following components a Hard disk drive b Cable from the system board to the backplane 3 Replace the following components one at a time in the order shown restarting the server each time a Hard disk drive b Cable from the system board to ...

Страница 529: ...kplane n hard disk drive number 806f020d 0402ffff Failure Predicted on drive StorageVolumeElementName for array ComputerSystemElementName Drive 2 This message is for the use case when an implementation has detected an Array Failure is Predicted May also be shown as 806f020d0402ffff or 0x806f020d0402ffff Severity Warning Serviceable Yes Automatically notify support Yes Alert Category System Predict...

Страница 530: ...M Information Prefix PLAT ID 0168 User Response 1 Run the hard disk drive diagnostic test on drive n 2 Reseat the following components a Hard disk drive b Cable from the system board to the backplane 3 Replace the following components one at a time in the order shown restarting the server each time a Hard disk drive b Cable from the system board to the backplane c Hard disk drive backplane n hard ...

Страница 531: ...ame Drive 5 This message is for the use case when an implementation has detected an Array Failure is Predicted May also be shown as 806f020d0405ffff or 0x806f020d0405ffff Severity Warning Serviceable Yes Automatically notify support Yes Alert Category System Predicted Failure SNMP Trap ID 27 CIM Information Prefix PLAT ID 0168 User Response 1 Run the hard disk drive diagnostic test on drive n 2 Re...

Страница 532: ...Hard disk drive b Cable from the system board to the backplane 3 Replace the following components one at a time in the order shown restarting the server each time a Hard disk drive b Cable from the system board to the backplane c Hard disk drive backplane n hard disk drive number 806f020d 0407ffff Failure Predicted on drive StorageVolumeElementName for array ComputerSystemElementName Drive 7 This ...

Страница 533: ...08ffff Severity Warning Serviceable Yes Automatically notify support Yes Alert Category System Predicted Failure SNMP Trap ID 27 CIM Information Prefix PLAT ID 0168 User Response 1 Run the hard disk drive diagnostic test on drive n 2 Reseat the following components a Hard disk drive b Cable from the system board to the backplane 3 Replace the following components one at a time in the order shown r...

Страница 534: ...from the system board to the backplane c Hard disk drive backplane n hard disk drive number 806f020d 040affff Failure Predicted on drive StorageVolumeElementName for array ComputerSystemElementName Drive 10 This message is for the use case when an implementation has detected an Array Failure is Predicted May also be shown as 806f020d040affff or 0x806f020d040affff Severity Warning Serviceable Yes A...

Страница 535: ... Yes Alert Category System Predicted Failure SNMP Trap ID 27 CIM Information Prefix PLAT ID 0168 User Response 1 Run the hard disk drive diagnostic test on drive n 2 Reseat the following components a Hard disk drive b Cable from the system board to the backplane 3 Replace the following components one at a time in the order shown restarting the server each time a Hard disk drive b Cable from the sy...

Страница 536: ...puterSystemElementName Drive 13 This message is for the use case when an implementation has detected an Array Failure is Predicted May also be shown as 806f020d040dffff or 0x806f020d040dffff Severity Warning Serviceable Yes Automatically notify support Yes Alert Category System Predicted Failure SNMP Trap ID 27 CIM Information Prefix PLAT ID 0168 User Response 1 Run the hard disk drive diagnostic ...

Страница 537: ...d disk drive b Cable from the system board to the backplane 3 Replace the following components one at a time in the order shown restarting the server each time a Hard disk drive b Cable from the system board to the backplane c Hard disk drive backplane n hard disk drive number 806f020d 040fffff Failure Predicted on drive StorageVolumeElementName for array ComputerSystemElementName Drive 15 This me...

Страница 538: ...d0410ffff Severity Warning Serviceable Yes Automatically notify support Yes Alert Category System Predicted Failure SNMP Trap ID 27 CIM Information Prefix PLAT ID 0168 User Response 1 Run the hard disk drive diagnostic test on drive n 2 Reseat the following components a Hard disk drive b Cable from the system board to the backplane 3 Replace the following components one at a time in the order show...

Страница 539: ...m the system board to the backplane c Hard disk drive backplane n hard disk drive number 806f020d 0412ffff Failure Predicted on drive StorageVolumeElementName for array ComputerSystemElementName Drive 18 This message is for the use case when an implementation has detected an Array Failure is Predicted May also be shown as 806f020d0412ffff or 0x806f020d0412ffff Severity Warning Serviceable Yes Auto...

Страница 540: ...ort Yes Alert Category System Predicted Failure SNMP Trap ID 27 CIM Information Prefix PLAT ID 0168 User Response 1 Run the hard disk drive diagnostic test on drive n 2 Reseat the following components a Hard disk drive b Cable from the system board to the backplane 3 Replace the following components one at a time in the order shown restarting the server each time a Hard disk drive b Cable from the...

Страница 541: ...erSystemElementName Drive 21 This message is for the use case when an implementation has detected an Array Failure is Predicted May also be shown as 806f020d0415ffff or 0x806f020d0415ffff Severity Warning Serviceable Yes Automatically notify support Yes Alert Category System Predicted Failure SNMP Trap ID 27 CIM Information Prefix PLAT ID 0168 User Response 1 Run the hard disk drive diagnostic tes...

Страница 542: ...Hard disk drive b Cable from the system board to the backplane 3 Replace the following components one at a time in the order shown restarting the server each time a Hard disk drive b Cable from the system board to the backplane c Hard disk drive backplane n hard disk drive number 806f020d 0417ffff Failure Predicted on drive StorageVolumeElementName for array ComputerSystemElementName Drive 23 This...

Страница 543: ...18ffff Severity Warning Serviceable Yes Automatically notify support Yes Alert Category System Predicted Failure SNMP Trap ID 27 CIM Information Prefix PLAT ID 0168 User Response 1 Run the hard disk drive diagnostic test on drive n 2 Reseat the following components a Hard disk drive b Cable from the system board to the backplane 3 Replace the following components one at a time in the order shown r...

Страница 544: ...from the system board to the backplane c Hard disk drive backplane n hard disk drive number 806f020d 041affff Failure Predicted on drive StorageVolumeElementName for array ComputerSystemElementName Drive 26 This message is for the use case when an implementation has detected an Array Failure is Predicted May also be shown as 806f020d041affff or 0x806f020d041affff Severity Warning Serviceable Yes A...

Страница 545: ... Yes Alert Category System Predicted Failure SNMP Trap ID 27 CIM Information Prefix PLAT ID 0168 User Response 1 Run the hard disk drive diagnostic test on drive n 2 Reseat the following components a Hard disk drive b Cable from the system board to the backplane 3 Replace the following components one at a time in the order shown restarting the server each time a Hard disk drive b Cable from the sy...

Страница 546: ...puterSystemElementName Drive 29 This message is for the use case when an implementation has detected an Array Failure is Predicted May also be shown as 806f020d041dffff or 0x806f020d041dffff Severity Warning Serviceable Yes Automatically notify support Yes Alert Category System Predicted Failure SNMP Trap ID 27 CIM Information Prefix PLAT ID 0168 User Response 1 Run the hard disk drive diagnostic ...

Страница 547: ...d disk drive b Cable from the system board to the backplane 3 Replace the following components one at a time in the order shown restarting the server each time a Hard disk drive b Cable from the system board to the backplane c Hard disk drive backplane n hard disk drive number 806f020d 041fffff Failure Predicted on drive StorageVolumeElementName for array ComputerSystemElementName Drive 31 This me...

Страница 548: ...lementName IPMI Watchdog This message is for the use case when an implementation has detected a Poweroff by Watchdog has occurred May also be shown as 806f02232101ffff or 0x806f02232101ffff Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0372 User Response No action information only 806f0308 0a01ffff PowerSupplyEl...

Страница 549: ... be shown as 806f03080a02ffff or 0x806f03080a02ffff Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0100 User Response 1 Reconnect the power cords 2 Check power supply n LED 3 See Power supply LEDs for more information n power supply number 806f030c 2001ffff Scrub Failure for PhysicalMemoryElementName on Subsystem...

Страница 550: ...MM 4 Trained service technician only Remove the affected microprocessor and check the microprocessor socket pins for any damaged pins If a damage is found replace the system board 5 Trained technician only If the problem occurs on the same DIMM connector check the DIMM connector If the connector contains any foreign material or is damaged replace the system board 6 Trained technician only Replace ...

Страница 551: ...e connector contains any foreign material or is damaged replace the system board 6 Trained technician only Replace the affected microprocessor 806f030c 2003ffff Scrub Failure for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 3 This message is for the use case when an implementation has detected a Memory Scrub failure May also be shown as 806f030c2003ffff or 0x806f030c2003ffff Sever...

Страница 552: ...l Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0136 User Response Note Each time you install or remove a DIMM you must disconnect the server from the power source then wait 10 seconds before restarting the server 1 Check the IBM support website for an applicable retain tip or firmware update that applies to this memory error 2 Swap the affected DIMMs as indicated by the error LEDs on the ...

Страница 553: ... on the system board or the event logs to a different memory channel or microprocessor 3 If the error still occurs on the same DIMM replace the affected DIMM 4 Trained service technician only Remove the affected microprocessor and check the microprocessor socket pins for any damaged pins If a damage is found replace the system board 5 Trained technician only If the problem occurs on the same DIMM ...

Страница 554: ...ffected microprocessor and check the microprocessor socket pins for any damaged pins If a damage is found replace the system board 5 Trained technician only If the problem occurs on the same DIMM connector check the DIMM connector If the connector contains any foreign material or is damaged replace the system board 6 Trained technician only Replace the affected microprocessor 806f030c 2007ffff Scr...

Страница 555: ...fff Scrub Failure for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 8 This message is for the use case when an implementation has detected a Memory Scrub failure May also be shown as 806f030c2008ffff or 0x806f030c2008ffff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0136 User Response No...

Страница 556: ...te for an applicable retain tip or firmware update that applies to this memory error 2 Swap the affected DIMMs as indicated by the error LEDs on the system board or the event logs to a different memory channel or microprocessor 3 If the error still occurs on the same DIMM replace the affected DIMM 4 Trained service technician only Remove the affected microprocessor and check the microprocessor soc...

Страница 557: ... Trained service technician only Remove the affected microprocessor and check the microprocessor socket pins for any damaged pins If a damage is found replace the system board 5 Trained technician only If the problem occurs on the same DIMM connector check the DIMM connector If the connector contains any foreign material or is damaged replace the system board 6 Trained technician only Replace the ...

Страница 558: ...the connector contains any foreign material or is damaged replace the system board 6 Trained technician only Replace the affected microprocessor 806f030c 200cffff Scrub Failure for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 12 This message is for the use case when an implementation has detected a Memory Scrub failure May also be shown as 806f030c200cffff or 0x806f030c200cffff Se...

Страница 559: ...emory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0136 User Response Note Each time you install or remove a DIMM you must disconnect the server from the power source then wait 10 seconds before restarting the server 1 Check the IBM support website for an applicable retain tip or firmware update that applies to this memory error 2 Swap the affected DIMMs as indicated by the error LEDs on the sys...

Страница 560: ...EDs on the system board or the event logs to a different memory channel or microprocessor 3 If the error still occurs on the same DIMM replace the affected DIMM 4 Trained service technician only Remove the affected microprocessor and check the microprocessor socket pins for any damaged pins If a damage is found replace the system board 5 Trained technician only If the problem occurs on the same DI...

Страница 561: ...cted microprocessor and check the microprocessor socket pins for any damaged pins If a damage is found replace the system board 5 Trained technician only If the problem occurs on the same DIMM connector check the DIMM connector If the connector contains any foreign material or is damaged replace the system board 6 Trained technician only Replace the affected microprocessor 806f030c 2010ffff Scrub ...

Страница 562: ...1ffff Scrub Failure for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 17 This message is for the use case when an implementation has detected a Memory Scrub failure May also be shown as 806f030c2011ffff or 0x806f030c2011ffff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0136 User Response...

Страница 563: ... for an applicable retain tip or firmware update that applies to this memory error 2 Swap the affected DIMMs as indicated by the error LEDs on the system board or the event logs to a different memory channel or microprocessor 3 If the error still occurs on the same DIMM replace the affected DIMM 4 Trained service technician only Remove the affected microprocessor and check the microprocessor socke...

Страница 564: ...M 4 Trained service technician only Remove the affected microprocessor and check the microprocessor socket pins for any damaged pins If a damage is found replace the system board 5 Trained technician only If the problem occurs on the same DIMM connector check the DIMM connector If the connector contains any foreign material or is damaged replace the system board 6 Trained technician only Replace t...

Страница 565: ... connector contains any foreign material or is damaged replace the system board 6 Trained technician only Replace the affected microprocessor 806f030c 2015ffff Scrub Failure for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 21 This message is for the use case when an implementation has detected a Memory Scrub failure May also be shown as 806f030c2015ffff or 0x806f030c2015ffff Sever...

Страница 566: ...l Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0136 User Response Note Each time you install or remove a DIMM you must disconnect the server from the power source then wait 10 seconds before restarting the server 1 Check the IBM support website for an applicable retain tip or firmware update that applies to this memory error 2 Swap the affected DIMMs as indicated by the error LEDs on the ...

Страница 567: ... on the system board or the event logs to a different memory channel or microprocessor 3 If the error still occurs on the same DIMM replace the affected DIMM 4 Trained service technician only Remove the affected microprocessor and check the microprocessor socket pins for any damaged pins If a damage is found replace the system board 5 Trained technician only If the problem occurs on the same DIMM ...

Страница 568: ...ove the affected microprocessor and check the microprocessor socket pins for any damaged pins If a damage is found replace the system board 5 Trained technician only If the problem occurs on the same DIMM connector check the DIMM connector If the connector contains any foreign material or is damaged replace the system board 6 Trained technician only Replace the affected microprocessor 806f0313 170...

Страница 569: ...6f03232101ffff Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0374 User Response No action information only 806f040c 2001ffff PhysicalMemoryElementName Disabled on Subsystem MemoryElementName DIMM 1 This message is for the use case when an implementation has detected that Memory has been Disabled May also be show...

Страница 570: ...detected that Memory has been Disabled May also be shown as 806f040c2002ffff or 0x806f040c2002ffff Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0131 User Response 1 Make sure the DIMM is installed correctly 2 If the DIMM was disabled because of a memory fault memory uncorrectable error or memory logging limit r...

Страница 571: ... to another slot and restart the server 4 Check the IBM support website for an applicable retain tip or firmware update that applies to this memory event If no memory fault is recorded in the logs and no DIMM connector error LED is lit you can re enable the DIMM through the Setup utility or the Advanced Settings Utility ASU 806f040c 2004ffff PhysicalMemoryElementName Disabled on Subsystem MemoryEl...

Страница 572: ...as 806f040c2005ffff or 0x806f040c2005ffff Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0131 User Response 1 Make sure the DIMM is installed correctly 2 If the DIMM was disabled because of a memory fault memory uncorrectable error or memory logging limit reached follow the suggested actions for that error event ...

Страница 573: ...ort website for an applicable retain tip or firmware update that applies to this memory event If no memory fault is recorded in the logs and no DIMM connector error LED is lit you can re enable the DIMM through the Setup utility or the Advanced Settings Utility ASU 806f040c 2007ffff PhysicalMemoryElementName Disabled on Subsystem MemoryElementName DIMM 7 This message is for the use case when an im...

Страница 574: ...f Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0131 User Response 1 Make sure the DIMM is installed correctly 2 If the DIMM was disabled because of a memory fault memory uncorrectable error or memory logging limit reached follow the suggested actions for that error event and restart the server 3 Install the DIM...

Страница 575: ...tip or firmware update that applies to this memory event If no memory fault is recorded in the logs and no DIMM connector error LED is lit you can re enable the DIMM through the Setup utility or the Advanced Settings Utility ASU 806f040c 200affff PhysicalMemoryElementName Disabled on Subsystem MemoryElementName DIMM 10 This message is for the use case when an implementation has detected that Memor...

Страница 576: ...nfo Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0131 User Response 1 Make sure the DIMM is installed correctly 2 If the DIMM was disabled because of a memory fault memory uncorrectable error or memory logging limit reached follow the suggested actions for that error event and restart the server 3 Install the DIMM to another...

Страница 577: ... applies to this memory event If no memory fault is recorded in the logs and no DIMM connector error LED is lit you can re enable the DIMM through the Setup utility or the Advanced Settings Utility ASU 806f040c 200dffff PhysicalMemoryElementName Disabled on Subsystem MemoryElementName DIMM 13 This message is for the use case when an implementation has detected that Memory has been Disabled May als...

Страница 578: ...atically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0131 User Response 1 Make sure the DIMM is installed correctly 2 If the DIMM was disabled because of a memory fault memory uncorrectable error or memory logging limit reached follow the suggested actions for that error event and restart the server 3 Install the DIMM to another slot and restart the se...

Страница 579: ...nable the DIMM through the Setup utility or the Advanced Settings Utility ASU 806f040c 2010ffff PhysicalMemoryElementName Disabled on Subsystem MemoryElementName DIMM 16 This message is for the use case when an implementation has detected that Memory has been Disabled May also be shown as 806f040c2010ffff or 0x806f040c2010ffff Severity Info Serviceable No Automatically notify support No Alert Cate...

Страница 580: ...stalled correctly 2 If the DIMM was disabled because of a memory fault memory uncorrectable error or memory logging limit reached follow the suggested actions for that error event and restart the server 3 Install the DIMM to another slot and restart the server 4 Check the IBM support website for an applicable retain tip or firmware update that applies to this memory event If no memory fault is rec...

Страница 581: ...M 19 This message is for the use case when an implementation has detected that Memory has been Disabled May also be shown as 806f040c2013ffff or 0x806f040c2013ffff Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0131 User Response 1 Make sure the DIMM is installed correctly 2 If the DIMM was disabled because of a ...

Страница 582: ... for that error event and restart the server 3 Install the DIMM to another slot and restart the server 4 Check the IBM support website for an applicable retain tip or firmware update that applies to this memory event If no memory fault is recorded in the logs and no DIMM connector error LED is lit you can re enable the DIMM through the Setup utility or the Advanced Settings Utility ASU 806f040c 20...

Страница 583: ...ge is for the use case when an implementation has detected that Memory has been Disabled May also be shown as 806f040c2016ffff or 0x806f040c2016ffff Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0131 User Response 1 Make sure the DIMM is installed correctly 2 If the DIMM was disabled because of a memory fault me...

Страница 584: ...hat error event and restart the server 3 Install the DIMM to another slot and restart the server 4 Check the IBM support website for an applicable retain tip or firmware update that applies to this memory event If no memory fault is recorded in the logs and no DIMM connector error LED is lit you can re enable the DIMM through the Setup utility or the Advanced Settings Utility ASU 806f040c 2018ffff...

Страница 585: ...d May also be shown as 806f040c2581ffff or 0x806f040c2581ffff Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0131 User Response 1 Make sure the DIMM is installed correctly 2 If the DIMM was disabled because of a memory fault memory uncorrectable error or memory logging limit reached follow the suggested actions f...

Страница 586: ...If the device is part of a cluster solution verify that the latest level of code is supported for the cluster solution before you update the code 4 Remove both adapters 5 Replace the PCIe adapters 6 Replace the riser card 806f0507 0301ffff ProcessorElementName has a Configuration Mismatch CPU 1 This message is for the use case when an implementation has detected a Processor Configuration Mismatch ...

Страница 587: ...ssor Configuration Mismatch has occurred May also be shown as 806f05070302ffff or 0x806f05070302ffff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical CPU SNMP Trap ID 40 CIM Information Prefix PLAT ID 0062 User Response 1 Check the CPU LED See more information about the CPU LED in Light path diagnostics 2 Check for a server firmware update Important Some clust...

Страница 588: ...ter solution verify that the latest level of code is supported for the cluster solution before you update the code 3 Make sure that the installed microprocessors are compatible with each other 4 Trained technician only Reseat microprocessor n 5 Trained technician only Replace microprocessor n n microprocessor number 806f050c 2001ffff Memory Logging Limit Reached for PhysicalMemoryElementName on Su...

Страница 589: ... system board 6 Trained technician only Replace the affected microprocessor 806f050c 2002ffff Memory Logging Limit Reached for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 2 This message is for the use case when an implementation has detected that the Memory Logging Limit has been Reached May also be shown as 806f050c2002ffff or 0x806f050c2002ffff Severity Warning Serviceable Yes ...

Страница 590: ...144 User Response 1 Check the IBM support website for an applicable retain tip or firmware update that applies to this memory error 2 Swap the affected DIMMs as indicated by the error LEDs on the system board or the event logs to a different memory channel or microprocessor 3 If the error still occurs on the same DIMM replace the affected DIMM 4 Trained technician only If the problem occurs on the...

Страница 591: ... DIMM connector check the DIMM connector If the connector contains any foreign material or is damaged replace the system board 5 Trained technician only Remove the affected microprocessor and check the microprocessor socket pins for any damaged pins If a damage is found replace the system board 6 Trained technician only Replace the affected microprocessor 806f050c 2005ffff Memory Logging Limit Rea...

Страница 592: ...eplace the system board 6 Trained technician only Replace the affected microprocessor 806f050c 2006ffff Memory Logging Limit Reached for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 6 This message is for the use case when an implementation has detected that the Memory Logging Limit has been Reached May also be shown as 806f050c2006ffff or 0x806f050c2006ffff Severity Warning Servic...

Страница 593: ... User Response 1 Check the IBM support website for an applicable retain tip or firmware update that applies to this memory error 2 Swap the affected DIMMs as indicated by the error LEDs on the system board or the event logs to a different memory channel or microprocessor 3 If the error still occurs on the same DIMM replace the affected DIMM 4 Trained technician only If the problem occurs on the sa...

Страница 594: ...ame DIMM connector check the DIMM connector If the connector contains any foreign material or is damaged replace the system board 5 Trained technician only Remove the affected microprocessor and check the microprocessor socket pins for any damaged pins If a damage is found replace the system board 6 Trained technician only Replace the affected microprocessor 806f050c 2009ffff Memory Logging Limit ...

Страница 595: ...ce the system board 6 Trained technician only Replace the affected microprocessor 806f050c 200affff Memory Logging Limit Reached for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 10 This message is for the use case when an implementation has detected that the Memory Logging Limit has been Reached May also be shown as 806f050c200affff or 0x806f050c200affff Severity Warning Serviceab...

Страница 596: ...144 User Response 1 Check the IBM support website for an applicable retain tip or firmware update that applies to this memory error 2 Swap the affected DIMMs as indicated by the error LEDs on the system board or the event logs to a different memory channel or microprocessor 3 If the error still occurs on the same DIMM replace the affected DIMM 4 Trained technician only If the problem occurs on the...

Страница 597: ...DIMM connector check the DIMM connector If the connector contains any foreign material or is damaged replace the system board 5 Trained technician only Remove the affected microprocessor and check the microprocessor socket pins for any damaged pins If a damage is found replace the system board 6 Trained technician only Replace the affected microprocessor 806f050c 200dffff Memory Logging Limit Reac...

Страница 598: ...place the system board 6 Trained technician only Replace the affected microprocessor 806f050c 200effff Memory Logging Limit Reached for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 14 This message is for the use case when an implementation has detected that the Memory Logging Limit has been Reached May also be shown as 806f050c200effff or 0x806f050c200effff Severity Warning Servic...

Страница 599: ... User Response 1 Check the IBM support website for an applicable retain tip or firmware update that applies to this memory error 2 Swap the affected DIMMs as indicated by the error LEDs on the system board or the event logs to a different memory channel or microprocessor 3 If the error still occurs on the same DIMM replace the affected DIMM 4 Trained technician only If the problem occurs on the sa...

Страница 600: ...me DIMM connector check the DIMM connector If the connector contains any foreign material or is damaged replace the system board 5 Trained technician only Remove the affected microprocessor and check the microprocessor socket pins for any damaged pins If a damage is found replace the system board 6 Trained technician only Replace the affected microprocessor 806f050c 2011ffff Memory Logging Limit R...

Страница 601: ...ce the system board 6 Trained technician only Replace the affected microprocessor 806f050c 2012ffff Memory Logging Limit Reached for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 18 This message is for the use case when an implementation has detected that the Memory Logging Limit has been Reached May also be shown as 806f050c2012ffff or 0x806f050c2012ffff Severity Warning Serviceab...

Страница 602: ...144 User Response 1 Check the IBM support website for an applicable retain tip or firmware update that applies to this memory error 2 Swap the affected DIMMs as indicated by the error LEDs on the system board or the event logs to a different memory channel or microprocessor 3 If the error still occurs on the same DIMM replace the affected DIMM 4 Trained technician only If the problem occurs on the...

Страница 603: ...DIMM connector check the DIMM connector If the connector contains any foreign material or is damaged replace the system board 5 Trained technician only Remove the affected microprocessor and check the microprocessor socket pins for any damaged pins If a damage is found replace the system board 6 Trained technician only Replace the affected microprocessor 806f050c 2015ffff Memory Logging Limit Reac...

Страница 604: ...place the system board 6 Trained technician only Replace the affected microprocessor 806f050c 2016ffff Memory Logging Limit Reached for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 22 This message is for the use case when an implementation has detected that the Memory Logging Limit has been Reached May also be shown as 806f050c2016ffff or 0x806f050c2016ffff Severity Warning Servic...

Страница 605: ... User Response 1 Check the IBM support website for an applicable retain tip or firmware update that applies to this memory error 2 Swap the affected DIMMs as indicated by the error LEDs on the system board or the event logs to a different memory channel or microprocessor 3 If the error still occurs on the same DIMM replace the affected DIMM 4 Trained technician only If the problem occurs on the sa...

Страница 606: ...e DIMM connector check the DIMM connector If the connector contains any foreign material or is damaged replace the system board 5 Trained technician only Remove the affected microprocessor and check the microprocessor socket pins for any damaged pins If a damage is found replace the system board 6 Trained technician only Replace the affected microprocessor 806f050c 2581ffff Memory Logging Limit Re...

Страница 607: ...material or is damaged replace the system board 6 Trained technician only Replace the affected microprocessor One of the DIMMs 806f050d 0400ffff Array ComputerSystemElementName is in critical condition Drive 0 This message is for the use case when an implementation has detected that an Array is Critical May also be shown as 806f050d0400ffff or 0x806f050d0400ffff Severity Error Serviceable Yes Auto...

Страница 608: ... drive firmware are at the latest level 2 Make sure that the SAS cable is connected correctly 3 Replace the SAS cable 4 Check backplane cable connection 5 Replace the RAID adapter 6 Replace the hard disk drive that is indicated by a lit status LED 806f050d 0402ffff Array ComputerSystemElementName is in critical condition Drive 2 This message is for the use case when an implementation has detected ...

Страница 609: ...0403ffff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0174 User Response 1 Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level 2 Make sure that the SAS cable is connected correctly 3 Replace the SAS cable 4 Check backplane cable connection 5 Replace the ...

Страница 610: ...e hard disk drive that is indicated by a lit status LED 806f050d 0405ffff Array ComputerSystemElementName is in critical condition Drive 5 This message is for the use case when an implementation has detected that an Array is Critical May also be shown as 806f050d0405ffff or 0x806f050d0405ffff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Hard Disk drive SNM...

Страница 611: ...itical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0174 User Response 1 Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level 2 Make sure that the SAS cable is connected correctly 3 Replace the SAS cable 4 Check backplane cable connection 5 Replace the RAID adapter 6 Replace the hard disk drive that is indicated by a lit status LED 806f050d...

Страница 612: ... condition Drive 8 This message is for the use case when an implementation has detected that an Array is Critical May also be shown as 806f050d0408ffff or 0x806f050d0408ffff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0174 User Response 1 Make sure that the RAID adapter firmware and hard disk d...

Страница 613: ...ive firmware are at the latest level 2 Make sure that the SAS cable is connected correctly 3 Replace the SAS cable 4 Check backplane cable connection 5 Replace the RAID adapter 6 Replace the hard disk drive that is indicated by a lit status LED 806f050d 040affff Array ComputerSystemElementName is in critical condition Drive 10 This message is for the use case when an implementation has detected th...

Страница 614: ...50d040bffff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0174 User Response 1 Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level 2 Make sure that the SAS cable is connected correctly 3 Replace the SAS cable 4 Check backplane cable connection 5 Replace t...

Страница 615: ...rd disk drive that is indicated by a lit status LED 806f050d 040dffff Array ComputerSystemElementName is in critical condition Drive 13 This message is for the use case when an implementation has detected that an Array is Critical May also be shown as 806f050d040dffff or 0x806f050d040dffff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Hard Disk drive SNMP T...

Страница 616: ... Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0174 User Response 1 Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level 2 Make sure that the SAS cable is connected correctly 3 Replace the SAS cable 4 Check backplane cable connection 5 Replace the RAID adapter 6 Replace the hard disk drive that is indicated by a lit status LED 806f0...

Страница 617: ...ndition Drive 16 This message is for the use case when an implementation has detected that an Array is Critical May also be shown as 806f050d0410ffff or 0x806f050d0410ffff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0174 User Response 1 Make sure that the RAID adapter firmware and hard disk dri...

Страница 618: ... drive firmware are at the latest level 2 Make sure that the SAS cable is connected correctly 3 Replace the SAS cable 4 Check backplane cable connection 5 Replace the RAID adapter 6 Replace the hard disk drive that is indicated by a lit status LED 806f050d 0412ffff Array ComputerSystemElementName is in critical condition Drive 18 This message is for the use case when an implementation has detected...

Страница 619: ...0413ffff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0174 User Response 1 Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level 2 Make sure that the SAS cable is connected correctly 3 Replace the SAS cable 4 Check backplane cable connection 5 Replace the ...

Страница 620: ... hard disk drive that is indicated by a lit status LED 806f050d 0415ffff Array ComputerSystemElementName is in critical condition Drive 21 This message is for the use case when an implementation has detected that an Array is Critical May also be shown as 806f050d0415ffff or 0x806f050d0415ffff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Hard Disk drive SNM...

Страница 621: ...itical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0174 User Response 1 Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level 2 Make sure that the SAS cable is connected correctly 3 Replace the SAS cable 4 Check backplane cable connection 5 Replace the RAID adapter 6 Replace the hard disk drive that is indicated by a lit status LED 806f050d...

Страница 622: ... condition Drive 24 This message is for the use case when an implementation has detected that an Array is Critical May also be shown as 806f050d0418ffff or 0x806f050d0418ffff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0174 User Response 1 Make sure that the RAID adapter firmware and hard disk ...

Страница 623: ...ive firmware are at the latest level 2 Make sure that the SAS cable is connected correctly 3 Replace the SAS cable 4 Check backplane cable connection 5 Replace the RAID adapter 6 Replace the hard disk drive that is indicated by a lit status LED 806f050d 041affff Array ComputerSystemElementName is in critical condition Drive 26 This message is for the use case when an implementation has detected th...

Страница 624: ...50d041bffff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0174 User Response 1 Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level 2 Make sure that the SAS cable is connected correctly 3 Replace the SAS cable 4 Check backplane cable connection 5 Replace t...

Страница 625: ...rd disk drive that is indicated by a lit status LED 806f050d 041dffff Array ComputerSystemElementName is in critical condition Drive 29 This message is for the use case when an implementation has detected that an Array is Critical May also be shown as 806f050d041dffff or 0x806f050d041dffff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Hard Disk drive SNMP T...

Страница 626: ... Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0174 User Response 1 Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level 2 Make sure that the SAS cable is connected correctly 3 Replace the SAS cable 4 Check backplane cable connection 5 Replace the RAID adapter 6 Replace the hard disk drive that is indicated by a lit status LED 806f0...

Страница 627: ...is message is for the use case when an implementation has detected a PCI SERR May also be shown as 806f05132582ffff or 0x806f05132582ffff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Other SNMP Trap ID 50 CIM Information Prefix PLAT ID 0234 User Response 1 Check the PCI LED 2 Reseat the affected adapters and riser card 3 Update the server firmware UEFI and...

Страница 628: ...mum configuration to start see Power supply LEDs 2 Recover the server firmware from the backup page by restarting the server 3 Update the server firmware to the latest level see Updating the firmware Important Some cluster solutions require specific code levels or coordinated code updates If the device is part of a cluster solution verify that the latest level of code is supported for the cluster ...

Страница 629: ...or ProcessorElementName has asserted CPU 2 This message is for the use case when an SM BIOS Uncorrectable CPU complex error has asserted May also be shown as 806f06070302ffff or 0x806f06070302ffff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical CPU SNMP Trap ID 40 CIM Information Prefix PLAT ID 0816 User Response 1 Make sure that the installed microprocessors...

Страница 630: ...r see Installing a microprocessor and heat sink for information about microprocessor requirements 2 Update the server firmware to the latest level see Updating the firmware 3 Trained technician only Replace the incompatible microprocessor One of the CPUs 806f0608 1301ffff PowerSupplyElementName has a Configuration Mismatch PS Configuration This message is for the use case when an implementation ha...

Страница 631: ... Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0176 User Response 1 Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level 2 Make sure that the SAS cable is connected correctly 3 Replace the SAS cable 4 Replace the RAID adapter 5 Replace the hard disk drive that is indicated by a lit status LED 806f060d 0401ffff Array ComputerSystemElementName has ...

Страница 632: ...hen an implementation has detected that an Array Failed May also be shown as 806f060d0402ffff or 0x806f060d0402ffff Severity Error Serviceable Yes Automatically notify support Yes Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0176 User Response 1 Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level 2 Make sure that th...

Страница 633: ...e sure that the SAS cable is connected correctly 3 Replace the SAS cable 4 Replace the RAID adapter 5 Replace the hard disk drive that is indicated by a lit status LED 806f060d 0404ffff Array ComputerSystemElementName has failed Drive 4 This message is for the use case when an implementation has detected that an Array Failed May also be shown as 806f060d0404ffff or 0x806f060d0404ffff Severity Erro...

Страница 634: ...s Automatically notify support Yes Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0176 User Response 1 Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level 2 Make sure that the SAS cable is connected correctly 3 Replace the SAS cable 4 Replace the RAID adapter 5 Replace the hard disk drive that is indicated by a lit st...

Страница 635: ...led Drive 7 This message is for the use case when an implementation has detected that an Array Failed May also be shown as 806f060d0407ffff or 0x806f060d0407ffff Severity Error Serviceable Yes Automatically notify support Yes Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0176 User Response 1 Make sure that the RAID adapter firmware and hard disk drive firmwa...

Страница 636: ... drive firmware are at the latest level 2 Make sure that the SAS cable is connected correctly 3 Replace the SAS cable 4 Replace the RAID adapter 5 Replace the hard disk drive that is indicated by a lit status LED 806f060d 0409ffff Array ComputerSystemElementName has failed Drive 9 This message is for the use case when an implementation has detected that an Array Failed May also be shown as 806f060...

Страница 637: ...ble Yes Automatically notify support Yes Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0176 User Response 1 Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level 2 Make sure that the SAS cable is connected correctly 3 Replace the SAS cable 4 Replace the RAID adapter 5 Replace the hard disk drive that is indicated by a ...

Страница 638: ... failed Drive 12 This message is for the use case when an implementation has detected that an Array Failed May also be shown as 806f060d040cffff or 0x806f060d040cffff Severity Error Serviceable Yes Automatically notify support Yes Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0176 User Response 1 Make sure that the RAID adapter firmware and hard disk drive f...

Страница 639: ...rd disk drive firmware are at the latest level 2 Make sure that the SAS cable is connected correctly 3 Replace the SAS cable 4 Replace the RAID adapter 5 Replace the hard disk drive that is indicated by a lit status LED 806f060d 040effff Array ComputerSystemElementName has failed Drive 14 This message is for the use case when an implementation has detected that an Array Failed May also be shown as...

Страница 640: ...rity Error Serviceable Yes Automatically notify support Yes Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0176 User Response 1 Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level 2 Make sure that the SAS cable is connected correctly 3 Replace the SAS cable 4 Replace the RAID adapter 5 Replace the hard disk drive that...

Страница 641: ...has failed Drive 17 This message is for the use case when an implementation has detected that an Array Failed May also be shown as 806f060d0411ffff or 0x806f060d0411ffff Severity Error Serviceable Yes Automatically notify support Yes Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0176 User Response 1 Make sure that the RAID adapter firmware and hard disk driv...

Страница 642: ... hard disk drive firmware are at the latest level 2 Make sure that the SAS cable is connected correctly 3 Replace the SAS cable 4 Replace the RAID adapter 5 Replace the hard disk drive that is indicated by a lit status LED 806f060d 0413ffff Array ComputerSystemElementName has failed Drive 19 This message is for the use case when an implementation has detected that an Array Failed May also be shown...

Страница 643: ...y Error Serviceable Yes Automatically notify support Yes Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0176 User Response 1 Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level 2 Make sure that the SAS cable is connected correctly 3 Replace the SAS cable 4 Replace the RAID adapter 5 Replace the hard disk drive that is...

Страница 644: ...me has failed Drive 22 This message is for the use case when an implementation has detected that an Array Failed May also be shown as 806f060d0416ffff or 0x806f060d0416ffff Severity Error Serviceable Yes Automatically notify support Yes Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0176 User Response 1 Make sure that the RAID adapter firmware and hard disk d...

Страница 645: ...rd disk drive firmware are at the latest level 2 Make sure that the SAS cable is connected correctly 3 Replace the SAS cable 4 Replace the RAID adapter 5 Replace the hard disk drive that is indicated by a lit status LED 806f060d 0418ffff Array ComputerSystemElementName has failed Drive 24 This message is for the use case when an implementation has detected that an Array Failed May also be shown as...

Страница 646: ...rity Error Serviceable Yes Automatically notify support Yes Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0176 User Response 1 Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level 2 Make sure that the SAS cable is connected correctly 3 Replace the SAS cable 4 Replace the RAID adapter 5 Replace the hard disk drive that...

Страница 647: ...has failed Drive 27 This message is for the use case when an implementation has detected that an Array Failed May also be shown as 806f060d041bffff or 0x806f060d041bffff Severity Error Serviceable Yes Automatically notify support Yes Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0176 User Response 1 Make sure that the RAID adapter firmware and hard disk driv...

Страница 648: ... hard disk drive firmware are at the latest level 2 Make sure that the SAS cable is connected correctly 3 Replace the SAS cable 4 Replace the RAID adapter 5 Replace the hard disk drive that is indicated by a lit status LED 806f060d 041dffff Array ComputerSystemElementName has failed Drive 29 This message is for the use case when an implementation has detected that an Array Failed May also be shown...

Страница 649: ...y Error Serviceable Yes Automatically notify support Yes Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0176 User Response 1 Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level 2 Make sure that the SAS cable is connected correctly 3 Replace the SAS cable 4 Replace the RAID adapter 5 Replace the hard disk drive that is...

Страница 650: ...lMemoryElementName on Subsystem MemoryElementName DIMM 1 This message is for the use case when an implementation has detected a Memory DIMM configuration error has been corrected May also be shown as 806f070c2001ffff or 0x806f070c2001ffff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0126 User Response M...

Страница 651: ...and technology 806f070c 2003ffff Configuration Error for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 3 This message is for the use case when an implementation has detected a Memory DIMM configuration error has been corrected May also be shown as 806f070c2003ffff or 0x806f070c2003ffff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Memory SNM...

Страница 652: ...26 User Response Make sure that DIMMs are installed in the correct sequence and have the same size type speed and technology 806f070c 2005ffff Configuration Error for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 5 This message is for the use case when an implementation has detected a Memory DIMM configuration error has been corrected May also be shown as 806f070c2005ffff or 0x806f...

Страница 653: ...t Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0126 User Response Make sure that DIMMs are installed in the correct sequence and have the same size type speed and technology 806f070c 2007ffff Configuration Error for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 7 This message is for the use case when an implementation has detected a Memory DIMM configurat...

Страница 654: ...Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0126 User Response Make sure that DIMMs are installed in the correct sequence and have the same size type speed and technology 806f070c 2009ffff Configuration Error for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 9 This message is for the use case when an implementation h...

Страница 655: ...ror Serviceable Yes Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0126 User Response Make sure that DIMMs are installed in the correct sequence and have the same size type speed and technology 806f070c 200bffff Configuration Error for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 11 This message is for the use case whe...

Страница 656: ...f or 0x806f070c200cffff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0126 User Response Make sure that DIMMs are installed in the correct sequence and have the same size type speed and technology 806f070c 200dffff Configuration Error for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 13 T...

Страница 657: ...wn as 806f070c200effff or 0x806f070c200effff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0126 User Response Make sure that DIMMs are installed in the correct sequence and have the same size type speed and technology 806f070c 200fffff Configuration Error for PhysicalMemoryElementName on Subsystem Memory...

Страница 658: ...ed May also be shown as 806f070c2010ffff or 0x806f070c2010ffff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0126 User Response Make sure that DIMMs are installed in the correct sequence and have the same size type speed and technology 806f070c 2011ffff Configuration Error for PhysicalMemoryElementName o...

Страница 659: ...onfiguration error has been corrected May also be shown as 806f070c2012ffff or 0x806f070c2012ffff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0126 User Response Make sure that DIMMs are installed in the correct sequence and have the same size type speed and technology 806f070c 2013ffff Configuration Er...

Страница 660: ...e DIMM 20 This message is for the use case when an implementation has detected a Memory DIMM configuration error has been corrected May also be shown as 806f070c2014ffff or 0x806f070c2014ffff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0126 User Response Make sure that DIMMs are installed in the correc...

Страница 661: ...nd technology 806f070c 2016ffff Configuration Error for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 22 This message is for the use case when an implementation has detected a Memory DIMM configuration error has been corrected May also be shown as 806f070c2016ffff or 0x806f070c2016ffff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Memory SNM...

Страница 662: ...26 User Response Make sure that DIMMs are installed in the correct sequence and have the same size type speed and technology 806f070c 2018ffff Configuration Error for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 24 This message is for the use case when an implementation has detected a Memory DIMM configuration error has been corrected May also be shown as 806f070c2018ffff or 0x806...

Страница 663: ...port No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0126 User Response Make sure that DIMMs are installed in the correct sequence and have the same size type speed and technology One of the DIMMs 806f070d 0400ffff Rebuild in progress for Array in system ComputerSystemElementName Drive 0 This message is for the use case when an implementation has detected that an A...

Страница 664: ...tomatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0178 User Response No action information only 806f070d 0402ffff Rebuild in progress for Array in system ComputerSystemElementName Drive 2 This message is for the use case when an implementation has detected that an Array Rebuild is in Progress May also be shown as 806f070d0402ffff or 0x806f070d040...

Страница 665: ... Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0178 User Response No action information only 806f070d 0404ffff Rebuild in progress for Array in system ComputerSystemElementName Drive 4 This message is for the use case when an implementation has detected that an Array Rebuild is in Progress May also be shown as 806f070d0404ffff or 0x806f070d...

Страница 666: ...o Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0178 User Response No action information only 806f070d 0406ffff Rebuild in progress for Array in system ComputerSystemElementName Drive 6 This message is for the use case when an implementation has detected that an Array Rebuild is in Progress May also be shown as 806f070d0406ff...

Страница 667: ...everity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0178 User Response No action information only 806f070d 0408ffff Rebuild in progress for Array in system ComputerSystemElementName Drive 8 This message is for the use case when an implementation has detected that an Array Rebuild is in Progress May also be shown as 806...

Страница 668: ...0d0409ffff Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0178 User Response No action information only 806f070d 040affff Rebuild in progress for Array in system ComputerSystemElementName Drive 10 This message is for the use case when an implementation has detected that an Array Rebuild is in Progress May also be...

Страница 669: ...f or 0x806f070d040bffff Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0178 User Response No action information only 806f070d 040cffff Rebuild in progress for Array in system ComputerSystemElementName Drive 12 This message is for the use case when an implementation has detected that an Array Rebuild is in Progres...

Страница 670: ... as 806f070d040dffff or 0x806f070d040dffff Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0178 User Response No action information only 806f070d 040effff Rebuild in progress for Array in system ComputerSystemElementName Drive 14 This message is for the use case when an implementation has detected that an Array Re...

Страница 671: ...shown as 806f070d040fffff or 0x806f070d040fffff Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0178 User Response No action information only 806f070d 0410ffff Rebuild in progress for Array in system ComputerSystemElementName Drive 16 This message is for the use case when an implementation has detected that an Arr...

Страница 672: ...ay also be shown as 806f070d0411ffff or 0x806f070d0411ffff Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0178 User Response No action information only 806f070d 0412ffff Rebuild in progress for Array in system ComputerSystemElementName Drive 18 This message is for the use case when an implementation has detected ...

Страница 673: ...ss May also be shown as 806f070d0413ffff or 0x806f070d0413ffff Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0178 User Response No action information only 806f070d 0414ffff Rebuild in progress for Array in system ComputerSystemElementName Drive 20 This message is for the use case when an implementation has detec...

Страница 674: ...n Progress May also be shown as 806f070d0415ffff or 0x806f070d0415ffff Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0178 User Response No action information only 806f070d 0416ffff Rebuild in progress for Array in system ComputerSystemElementName Drive 22 This message is for the use case when an implementation h...

Страница 675: ...rogress May also be shown as 806f070d0417ffff or 0x806f070d0417ffff Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0178 User Response No action information only 806f070d 0418ffff Rebuild in progress for Array in system ComputerSystemElementName Drive 24 This message is for the use case when an implementation has ...

Страница 676: ...n Progress May also be shown as 806f070d0419ffff or 0x806f070d0419ffff Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0178 User Response No action information only 806f070d 041affff Rebuild in progress for Array in system ComputerSystemElementName Drive 26 This message is for the use case when an implementation h...

Страница 677: ...rogress May also be shown as 806f070d041bffff or 0x806f070d041bffff Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0178 User Response No action information only 806f070d 041cffff Rebuild in progress for Array in system ComputerSystemElementName Drive 28 This message is for the use case when an implementation has ...

Страница 678: ...n Progress May also be shown as 806f070d041dffff or 0x806f070d041dffff Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0178 User Response No action information only 806f070d 041effff Rebuild in progress for Array in system ComputerSystemElementName Drive 30 This message is for the use case when an implementation h...

Страница 679: ...e shown as 806f070d041fffff or 0x806f070d041fffff Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0178 User Response No action information only 806f072b 2201ffff A successful software or firmware change was detected on system ComputerSystemElementName Bkup Auto Update This message is for the use case when an imple...

Страница 680: ...Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0061 User Response 1 Make sure that the installed microprocessors are compatible with each other see Installing a microprocessor and heat sink for information about microprocessor requirements 2 Update the server firmware to the latest level see Updating the firmware 3 Trained technician only Replace the incompatible microprocessor ...

Страница 681: ...4ffff ProcessorElementName has been Disabled All CPUs This message is for the use case when an implementation has detected a Processor has been Disabled May also be shown as 806f08072584ffff or 0x806f08072584ffff Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0061 User Response 1 Make sure that the installed micr...

Страница 682: ... board 4 Check for a server firmware update Important Some cluster solutions require specific code levels or coordinated code updates If the device is part of a cluster solution verify that the latest level of code is supported for the cluster solution before you update the code 5 Make sure that the installed DIMMs are supported and configured correctly 6 Trained technician only Replace the system...

Страница 683: ...mElementName CPUs This message is for the use case when an implementation has detected a Bus Uncorrectable Error May also be shown as 806f08132584ffff or 0x806f08132584ffff Severity Error Serviceable Yes Automatically notify support Yes Alert Category Critical Other SNMP Trap ID 50 CIM Information Prefix PLAT ID 0240 User Response 1 Check the system event log 2 Reseat the failing microprocessor fr...

Страница 684: ...101ffff Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0376 User Response No action information only 806f090c 2001ffff PhysicalMemoryElementName on Subsystem MemoryElementName Throttled DIMM 1 This message is for the use case when an implementation has detected Memory has been Throttled May also be shown as 806f0...

Страница 685: ...rviceable Yes Automatically notify support No Alert Category System Other SNMP Trap ID 22 CIM Information Prefix PLAT ID 0142 User Response 1 Reseat the DIMM and then restart the server 2 Replace DIMM n n DIMM number 806f090c 2003ffff PhysicalMemoryElementName on Subsystem MemoryElementName Throttled DIMM 3 This message is for the use case when an implementation has detected Memory has been Thrott...

Страница 686: ...004ffff or 0x806f090c2004ffff Severity Warning Serviceable Yes Automatically notify support No Alert Category System Other SNMP Trap ID 22 CIM Information Prefix PLAT ID 0142 User Response 1 Reseat the DIMM and then restart the server 2 Replace DIMM n n DIMM number 806f090c 2005ffff PhysicalMemoryElementName on Subsystem MemoryElementName Throttled DIMM 5 This message is for the use case when an i...

Страница 687: ...ay also be shown as 806f090c2006ffff or 0x806f090c2006ffff Severity Warning Serviceable Yes Automatically notify support No Alert Category System Other SNMP Trap ID 22 CIM Information Prefix PLAT ID 0142 User Response 1 Reseat the DIMM and then restart the server 2 Replace DIMM n n DIMM number 806f090c 2007ffff PhysicalMemoryElementName on Subsystem MemoryElementName Throttled DIMM 7 This message ...

Страница 688: ...tem MemoryElementName Throttled DIMM 8 This message is for the use case when an implementation has detected Memory has been Throttled May also be shown as 806f090c2008ffff or 0x806f090c2008ffff Severity Warning Serviceable Yes Automatically notify support No Alert Category System Other SNMP Trap ID 22 CIM Information Prefix PLAT ID 0142 User Response 1 Reseat the DIMM and then restart the server 2...

Страница 689: ...x PLAT ID 0142 User Response 1 Reseat the DIMM and then restart the server 2 Replace DIMM n n DIMM number 806f090c 200affff PhysicalMemoryElementName on Subsystem MemoryElementName Throttled DIMM 10 This message is for the use case when an implementation has detected Memory has been Throttled May also be shown as 806f090c200affff or 0x806f090c200affff Severity Warning Serviceable Yes Automatically...

Страница 690: ...o Alert Category System Other SNMP Trap ID 22 CIM Information Prefix PLAT ID 0142 User Response 1 Reseat the DIMM and then restart the server 2 Replace DIMM n n DIMM number 806f090c 200cffff PhysicalMemoryElementName on Subsystem MemoryElementName Throttled DIMM 12 This message is for the use case when an implementation has detected Memory has been Throttled May also be shown as 806f090c200cffff o...

Страница 691: ...rviceable Yes Automatically notify support No Alert Category System Other SNMP Trap ID 22 CIM Information Prefix PLAT ID 0142 User Response 1 Reseat the DIMM and then restart the server 2 Replace DIMM n n DIMM number 806f090c 200effff PhysicalMemoryElementName on Subsystem MemoryElementName Throttled DIMM 14 This message is for the use case when an implementation has detected Memory has been Throt...

Страница 692: ...00fffff or 0x806f090c200fffff Severity Warning Serviceable Yes Automatically notify support No Alert Category System Other SNMP Trap ID 22 CIM Information Prefix PLAT ID 0142 User Response 1 Reseat the DIMM and then restart the server 2 Replace DIMM n n DIMM number 806f090c 2010ffff PhysicalMemoryElementName on Subsystem MemoryElementName Throttled DIMM 16 This message is for the use case when an ...

Страница 693: ...ay also be shown as 806f090c2011ffff or 0x806f090c2011ffff Severity Warning Serviceable Yes Automatically notify support No Alert Category System Other SNMP Trap ID 22 CIM Information Prefix PLAT ID 0142 User Response 1 Reseat the DIMM and then restart the server 2 Replace DIMM n n DIMM number 806f090c 2012ffff PhysicalMemoryElementName on Subsystem MemoryElementName Throttled DIMM 18 This message...

Страница 694: ...tem MemoryElementName Throttled DIMM 19 This message is for the use case when an implementation has detected Memory has been Throttled May also be shown as 806f090c2013ffff or 0x806f090c2013ffff Severity Warning Serviceable Yes Automatically notify support No Alert Category System Other SNMP Trap ID 22 CIM Information Prefix PLAT ID 0142 User Response 1 Reseat the DIMM and then restart the server ...

Страница 695: ...ix PLAT ID 0142 User Response 1 Reseat the DIMM and then restart the server 2 Replace DIMM n n DIMM number 806f090c 2015ffff PhysicalMemoryElementName on Subsystem MemoryElementName Throttled DIMM 21 This message is for the use case when an implementation has detected Memory has been Throttled May also be shown as 806f090c2015ffff or 0x806f090c2015ffff Severity Warning Serviceable Yes Automaticall...

Страница 696: ...o Alert Category System Other SNMP Trap ID 22 CIM Information Prefix PLAT ID 0142 User Response 1 Reseat the DIMM and then restart the server 2 Replace DIMM n n DIMM number 806f090c 2017ffff PhysicalMemoryElementName on Subsystem MemoryElementName Throttled DIMM 23 This message is for the use case when an implementation has detected Memory has been Throttled May also be shown as 806f090c2017ffff o...

Страница 697: ...iceable Yes Automatically notify support No Alert Category System Other SNMP Trap ID 22 CIM Information Prefix PLAT ID 0142 User Response 1 Reseat the DIMM and then restart the server 2 Replace DIMM n n DIMM number 806f0a07 0301ffff ProcessorElementName is operating in a Degraded State CPU 1 This message is for the use case when an implementation has detected a Processor is running in the Degraded...

Страница 698: ...ge is for the use case when an implementation has detected a Processor is running in the Degraded state May also be shown as 806f0a070302ffff or 0x806f0a070302ffff Severity Warning Serviceable Yes Automatically notify support No Alert Category Warning CPU SNMP Trap ID 42 CIM Information Prefix PLAT ID 0038 User Response 1 Make sure the air baffles heat sink are placed and correctly installed and m...

Страница 699: ...e the node cover is installed and completely closed 2 Make sure the fans are operating and there are no obstructions to the airflow 3 Reduce the Ambient temperature The system must be operating within the specifications see Features and specifications for more information 806f0a0c 2002ffff An Over Temperature Condition has been detected on the PhysicalMemoryElementName on Subsystem MemoryElementNa...

Страница 700: ...6f0a0c2003ffff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Temperature SNMP Trap ID 0 CIM Information Prefix PLAT ID 0146 User Response 1 Make sure the air baffles heat sink are placed and correctly installed and make sure the node cover is installed and completely closed 2 Make sure the fans are operating and there are no obstructions to the airflow 3 Re...

Страница 701: ...ng within the specifications see Features and specifications for more information 806f0a0c 2005ffff An Over Temperature Condition has been detected on the PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 5 This message is for the use case when an implementation has detected an Over Temperature Condition for Memory that has been Detected May also be shown as 806f0a0c2005ffff or 0x806f0...

Страница 702: ...e Yes Automatically notify support No Alert Category Critical Temperature SNMP Trap ID 0 CIM Information Prefix PLAT ID 0146 User Response 1 Make sure the air baffles heat sink are placed and correctly installed and make sure the node cover is installed and completely closed 2 Make sure the fans are operating and there are no obstructions to the airflow 3 Reduce the Ambient temperature The system ...

Страница 703: ... MemoryElementName DIMM 8 This message is for the use case when an implementation has detected an Over Temperature Condition for Memory that has been Detected May also be shown as 806f0a0c2008ffff or 0x806f0a0c2008ffff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Temperature SNMP Trap ID 0 CIM Information Prefix PLAT ID 0146 User Response 1 Make sure the a...

Страница 704: ...sure the node cover is installed and completely closed 2 Make sure the fans are operating and there are no obstructions to the airflow 3 Reduce the Ambient temperature The system must be operating within the specifications see Features and specifications for more information 806f0a0c 200affff An Over Temperature Condition has been detected on the PhysicalMemoryElementName on Subsystem MemoryElemen...

Страница 705: ...a0c200bffff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Temperature SNMP Trap ID 0 CIM Information Prefix PLAT ID 0146 User Response 1 Make sure the air baffles heat sink are placed and correctly installed and make sure the node cover is installed and completely closed 2 Make sure the fans are operating and there are no obstructions to the airflow 3 Reduc...

Страница 706: ...ting within the specifications see Features and specifications for more information 806f0a0c 200dffff An Over Temperature Condition has been detected on the PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 13 This message is for the use case when an implementation has detected an Over Temperature Condition for Memory that has been Detected May also be shown as 806f0a0c200dffff or 0x80...

Страница 707: ...es Automatically notify support No Alert Category Critical Temperature SNMP Trap ID 0 CIM Information Prefix PLAT ID 0146 User Response 1 Make sure the air baffles heat sink are placed and correctly installed and make sure the node cover is installed and completely closed 2 Make sure the fans are operating and there are no obstructions to the airflow 3 Reduce the Ambient temperature The system mus...

Страница 708: ...tem MemoryElementName DIMM 16 This message is for the use case when an implementation has detected an Over Temperature Condition for Memory that has been Detected May also be shown as 806f0a0c2010ffff or 0x806f0a0c2010ffff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Temperature SNMP Trap ID 0 CIM Information Prefix PLAT ID 0146 User Response 1 Make sure t...

Страница 709: ...e the node cover is installed and completely closed 2 Make sure the fans are operating and there are no obstructions to the airflow 3 Reduce the Ambient temperature The system must be operating within the specifications see Features and specifications for more information 806f0a0c 2012ffff An Over Temperature Condition has been detected on the PhysicalMemoryElementName on Subsystem MemoryElementNa...

Страница 710: ...6f0a0c2013ffff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Temperature SNMP Trap ID 0 CIM Information Prefix PLAT ID 0146 User Response 1 Make sure the air baffles heat sink are placed and correctly installed and make sure the node cover is installed and completely closed 2 Make sure the fans are operating and there are no obstructions to the airflow 3 Re...

Страница 711: ...g within the specifications see Features and specifications for more information 806f0a0c 2015ffff An Over Temperature Condition has been detected on the PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 21 This message is for the use case when an implementation has detected an Over Temperature Condition for Memory that has been Detected May also be shown as 806f0a0c2015ffff or 0x806f0...

Страница 712: ...e Yes Automatically notify support No Alert Category Critical Temperature SNMP Trap ID 0 CIM Information Prefix PLAT ID 0146 User Response 1 Make sure the air baffles heat sink are placed and correctly installed and make sure the node cover is installed and completely closed 2 Make sure the fans are operating and there are no obstructions to the airflow 3 Reduce the Ambient temperature The system ...

Страница 713: ... MemoryElementName DIMM 24 This message is for the use case when an implementation has detected an Over Temperature Condition for Memory that has been Detected May also be shown as 806f0a0c2018ffff or 0x806f0a0c2018ffff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Temperature SNMP Trap ID 0 CIM Information Prefix PLAT ID 0146 User Response 1 Make sure the ...

Страница 714: ...ponse 1 Reseat the microprocessor and then restart the server 2 Trained technician only Replace microprocessor n n microprocessor number 806f0a13 0302ffff A Fatal Bus Error has occurred on system ComputerSystemElementName CPU 2 PECI This message is for the use case when an implementation has detected a Bus Fatal Error May also be shown as 806f0a130302ffff or 0x806f0a130302ffff Severity Error Servi...

Страница 715: ...Info Serviceable No Automatically notify support No Alert Category Warning Voltage SNMP Trap ID 13 CIM Information Prefix PLAT ID 0477 User Response No action information only 81010202 0701ffff Numeric sensor NumericSensorElementName going low lower critical has deasserted CMOS Battery This message is for the use case when an implementation has detected a Lower Critical sensor going low has deasse...

Страница 716: ...f Severity Info Serviceable No Automatically notify support No Alert Category Critical Fan Failure SNMP Trap ID 11 CIM Information Prefix PLAT ID 0481 User Response No action information only Fan 1B Tach 81010204 1d02ffff Numeric sensor NumericSensorElementName going low lower critical has deasserted Fan 2A Tach This message is for the use case when an implementation has detected a Lower Critical ...

Страница 717: ...ceable No Automatically notify support No Alert Category Critical Fan Failure SNMP Trap ID 11 CIM Information Prefix PLAT ID 0481 User Response No action information only Fan 3B Tach 81010204 1d04ffff Numeric sensor NumericSensorElementName going low lower critical has deasserted Fan 4A Tach This message is for the use case when an implementation has detected a Lower Critical sensor going low has ...

Страница 718: ...01ffff Severity Info Serviceable No Automatically notify support No Alert Category Warning Temperature SNMP Trap ID 12 CIM Information Prefix PLAT ID 0491 User Response No action information only 81010701 0c01ffff Numeric sensor NumericSensorElementName going high upper non critical has deasserted Ambient Temp This message is for the use case when an implementation has detected an Upper Non critic...

Страница 719: ...001ffff Severity Info Serviceable No Automatically notify support No Alert Category Warning Temperature SNMP Trap ID 12 CIM Information Prefix PLAT ID 0491 User Response No action information only 81010701 1002ffff Numeric sensor NumericSensorElementName going high upper non critical has deasserted PCI Riser 2 Temp This message is for the use case when an implementation has detected an Upper Non c...

Страница 720: ...ffff or 0x810107011003ffff Severity Info Serviceable No Automatically notify support No Alert Category Warning Temperature SNMP Trap ID 12 CIM Information Prefix PLAT ID 0491 User Response No action information only 81010701 1401ffff Numeric sensor NumericSensorElementName going high upper non critical has deasserted CPU1 VR Temp This message is for the use case when an implementation has detected...

Страница 721: ...810107011402ffff or 0x810107011402ffff Severity Info Serviceable No Automatically notify support No Alert Category Warning Temperature SNMP Trap ID 12 CIM Information Prefix PLAT ID 0491 User Response No action information only 81010701 1403ffff Numeric sensor NumericSensorElementName going high upper non critical has deasserted DIMM AB VR Temp This message is for the use case when an implementati...

Страница 722: ...be shown as 810107011404ffff or 0x810107011404ffff Severity Info Serviceable No Automatically notify support No Alert Category Warning Temperature SNMP Trap ID 12 CIM Information Prefix PLAT ID 0491 User Response No action information only 81010701 1405ffff Numeric sensor NumericSensorElementName going high upper non critical has deasserted DIMM EF VR Temp This message is for the use case when an ...

Страница 723: ... also be shown as 810107011406ffff or 0x810107011406ffff Severity Info Serviceable No Automatically notify support No Alert Category Warning Temperature SNMP Trap ID 12 CIM Information Prefix PLAT ID 0491 User Response No action information only 81010701 2c01ffff Numeric sensor NumericSensorElementName going high upper non critical has deasserted Mezz Card Temp This message is for the use case whe...

Страница 724: ...easserted May also be shown as 810107012d01ffff or 0x810107012d01ffff Severity Info Serviceable No Automatically notify support No Alert Category Warning Temperature SNMP Trap ID 12 CIM Information Prefix PLAT ID 0491 User Response No action information only 81010901 0701ffff Numeric sensor NumericSensorElementName going high upper critical has deasserted ROMB Temp This message is for the use case...

Страница 725: ...erted May also be shown as 810109010c01ffff or 0x810109010c01ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Temperature SNMP Trap ID 0 CIM Information Prefix PLAT ID 0495 User Response No action information only 81010901 1001ffff Numeric sensor NumericSensorElementName going high upper critical has deasserted PCI Riser 1 Temp This message is for the use c...

Страница 726: ...s deasserted May also be shown as 810109011002ffff or 0x810109011002ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Temperature SNMP Trap ID 0 CIM Information Prefix PLAT ID 0495 User Response No action information only 81010901 1003ffff Numeric sensor NumericSensorElementName going high upper critical has deasserted Rear BP Temp This message is for the us...

Страница 727: ...sserted May also be shown as 810109011401ffff or 0x810109011401ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Temperature SNMP Trap ID 0 CIM Information Prefix PLAT ID 0495 User Response No action information only 81010901 1402ffff Numeric sensor NumericSensorElementName going high upper critical has deasserted CPU2 VR Temp This message is for the use cas...

Страница 728: ...deasserted May also be shown as 810109011403ffff or 0x810109011403ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Temperature SNMP Trap ID 0 CIM Information Prefix PLAT ID 0495 User Response No action information only 81010901 1404ffff Numeric sensor NumericSensorElementName going high upper critical has deasserted DIMM CD VR Temp This message is for the u...

Страница 729: ...sserted May also be shown as 810109011405ffff or 0x810109011405ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Temperature SNMP Trap ID 0 CIM Information Prefix PLAT ID 0495 User Response No action information only 81010901 1406ffff Numeric sensor NumericSensorElementName going high upper critical has deasserted DIMM GH VR Temp This message is for the use ...

Страница 730: ...as deasserted May also be shown as 810109012c01ffff or 0x810109012c01ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Temperature SNMP Trap ID 0 CIM Information Prefix PLAT ID 0495 User Response No action information only 81010901 2d01ffff Numeric sensor NumericSensorElementName going high upper critical has deasserted PCH Temp This message is for the use c...

Страница 731: ...10109020701ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Voltage SNMP Trap ID 1 CIM Information Prefix PLAT ID 0495 User Response If the specified sensor is one of the following SysBrd 3 3V SysBrd 5V or SysBrd 12V No action information only 81010b01 0701ffff Numeric sensor NumericSensorElementName going high upper non recoverable has deasserted ROMB Temp...

Страница 732: ...rable sensor going high has deasserted May also be shown as 81010b010c01ffff or 0x81010b010c01ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Temperature SNMP Trap ID 0 CIM Information Prefix PLAT ID 0499 User Response No action information only 81010b01 1001ffff Numeric sensor NumericSensorElementName going high upper non recoverable has deasserted PCI Ri...

Страница 733: ... Temp This message is for the use case when an implementation has detected an Upper Non recoverable sensor going high has deasserted May also be shown as 81010b011002ffff or 0x81010b011002ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Temperature SNMP Trap ID 0 CIM Information Prefix PLAT ID 0499 User Response No action information only 81010b01 1003ffff ...

Страница 734: ...ation only 81010b01 1401ffff Numeric sensor NumericSensorElementName going high upper non recoverable has deasserted CPU1 VR Temp This message is for the use case when an implementation has detected an Upper Non recoverable sensor going high has deasserted May also be shown as 81010b011401ffff or 0x81010b011401ffff Severity Info Serviceable No Automatically notify support No Alert Category Critica...

Страница 735: ...ation Prefix PLAT ID 0499 User Response No action information only 81010b01 1403ffff Numeric sensor NumericSensorElementName going high upper non recoverable has deasserted DIMM AB VR Temp This message is for the use case when an implementation has detected an Upper Non recoverable sensor going high has deasserted May also be shown as 81010b011403ffff or 0x81010b011403ffff Severity Info Serviceabl...

Страница 736: ...formation Prefix PLAT ID 0499 User Response No action information only 81010b01 1405ffff Numeric sensor NumericSensorElementName going high upper non recoverable has deasserted DIMM EF VR Temp This message is for the use case when an implementation has detected an Upper Non recoverable sensor going high has deasserted May also be shown as 81010b011405ffff or 0x81010b011405ffff Severity Info Servic...

Страница 737: ...rmation Prefix PLAT ID 0499 User Response No action information only 81010b01 2c01ffff Numeric sensor NumericSensorElementName going high upper non recoverable has deasserted Mezz Card Temp This message is for the use case when an implementation has detected an Upper Non recoverable sensor going high has deasserted May also be shown as 81010b012c01ffff or 0x81010b012c01ffff Severity Info Serviceab...

Страница 738: ...ry Critical Temperature SNMP Trap ID 0 CIM Information Prefix PLAT ID 0499 User Response No action information only 81030006 2101ffff Sensor SensorElementName has asserted Sig Verify Fail This message is for the use case when an implementation has detected a Sensor has asserted May also be shown as 810300062101ffff or 0x810300062101ffff Severity Info Serviceable No Automatically notify support No ...

Страница 739: ... only 81030108 1301ffff Sensor SensorElementName has deasserted PS Heavy Load This message is for the use case when an implementation has detected a Sensor has deasserted May also be shown as 810301081301ffff or 0x810301081301ffff Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0509 User Response No action informa...

Страница 740: ...formation only 8107010f 2201ffff Sensor SensorElementName has deasserted the transition from normal to non critical state GPT Status This message is for the use case when an implementation has detected that a Sensor has deasserted a transition to non critical from normal May also be shown as 8107010f2201ffff or 0x8107010f2201ffff Severity Info Serviceable No Automatically notify support No Alert C...

Страница 741: ...60 CIM Information Prefix PLAT ID 0521 User Response No action information only 81070201 0301ffff Sensor SensorElementName has transitioned to a less severe state from critical CPU 1 OverTemp This message is for the use case when an implementation has detected a Sensor transition to less severe from critical May also be shown as 810702010301ffff or 0x810702010301ffff Severity Info Serviceable No A...

Страница 742: ...nformation Prefix PLAT ID 0523 User Response No action information only 81070202 0701ffff Sensor SensorElementName has transitioned to a less severe state from critical SysBrd Vol Fault This message is for the use case when an implementation has detected a Sensor transition to less severe from critical May also be shown as 810702020701ffff or 0x810702020701ffff Severity Info Serviceable No Automat...

Страница 743: ...mation Prefix PLAT ID 0523 User Response No action information only 81070204 0a02ffff Sensor SensorElementName has transitioned to a less severe state from critical PS 2 Fan Fault This message is for the use case when an implementation has detected a Sensor transition to less severe from critical May also be shown as 810702040a02ffff or 0x810702040a02ffff Severity Info Serviceable No Automatically...

Страница 744: ...formation Prefix PLAT ID 0523 User Response No action information only 81070208 0a02ffff Sensor SensorElementName has transitioned to a less severe state from critical PS 2 Therm Fault This message is for the use case when an implementation has detected a Sensor transition to less severe from critical May also be shown as 810702080a02ffff or 0x810702080a02ffff Severity Info Serviceable No Automati...

Страница 745: ... Prefix PLAT ID 0523 User Response No action information only nvDIMM Flash 8107020f 2582ffff Sensor SensorElementName has transitioned to a less severe state from critical I O Resources This message is for the use case when an implementation has detected a Sensor transition to less severe from critical May also be shown as 8107020f2582ffff or 0x8107020f2582ffff Severity Info Serviceable No Automat...

Страница 746: ...rmation Prefix PLAT ID 0523 User Response No action information only 81070219 0701ffff Sensor SensorElementName has transitioned to a less severe state from critical SysBrd Fault This message is for the use case when an implementation has detected a Sensor transition to less severe from critical May also be shown as 810702190701ffff or 0x810702190701ffff Severity Info Serviceable No Automatically ...

Страница 747: ...mation Prefix PLAT ID 0523 User Response No action information only 8107021b 0302ffff Sensor SensorElementName has transitioned to a less severe state from critical CPU 2 QPILinkErr This message is for the use case when an implementation has detected a Sensor transition to less severe from critical May also be shown as 8107021b0302ffff or 0x8107021b0302ffff Severity Info Serviceable No Automatical...

Страница 748: ...formation Prefix PLAT ID 0525 User Response No action information only 81070301 0302ffff Sensor SensorElementName has deasserted the transition to non recoverable from a less severe state CPU 2 OverTemp This message is for the use case when an implementation has detected that the Sensor transition to non recoverable from less severe has deasserted May also be shown as 810703010302ffff or 0x8107030...

Страница 749: ...nse No action information only Pwr Rail B Fault Pwr Rail C Fault Pwr Rail D Fault Pwr Rail E Fault Pwr Rail F Fault Pwr Rail G Fault Pwr Rail H Fault 81070608 0a01ffff Sensor SensorElementName has deasserted the transition to non recoverable This message is for the use case when an implementation has detected that the Sensor transition to non recoverable has deasserted May also be shown as 8107060...

Страница 750: ...lly notify support No Alert Category Critical Power SNMP Trap ID 4 CIM Information Prefix PLAT ID 0531 User Response If the specified sensor is one of the following PS1 12V OC Fault PS1 12V OV Fault PS1 12V UV Fault or PS1 12Vaux Fault No action information only 810b010a 1e81ffff Redundancy Lost for RedundancySetElementName has deasserted Fan Zone 1 This message is for the use case when Redundacy ...

Страница 751: ...egory Critical Fan Failure SNMP Trap ID 11 CIM Information Prefix PLAT ID 0803 User Response No action information only 810b010c 2581ffff Redundancy Lost for RedundancySetElementName has deasserted Backup Memory This message is for the use case when Redundacy Lost has deasserted May also be shown as 810b010c2581ffff or 0x810b010c2581ffff Severity Info Serviceable No Automatically notify support No...

Страница 752: ...egory Warning Redundant Power Supply SNMP Trap ID 10 CIM Information Prefix PLAT ID 0807 User Response No action information only 810b030c 2581ffff Non redundant Sufficient Resources from Redundancy Degraded or Fully Redundant for RedundancySetElementName has deasserted Backup Memory This message is for the use case when a Redundancy Set has transitioned from Non redundant Sufficient Resources May...

Страница 753: ...t No Alert Category Critical Redundant Power Supply SNMP Trap ID 9 CIM Information Prefix PLAT ID 0811 User Response No action information only 810b050a 1e81ffff Non redundant Insufficient Resources for RedundancySetElementName has deasserted Fan Zone 1 This message is for the use case when a Redundancy Set has transitioned from Non redundant Insufficient Resources May also be shown as 810b050a1e8...

Страница 754: ...ly notify support No Alert Category Critical Fan Failure SNMP Trap ID 11 CIM Information Prefix PLAT ID 0811 User Response No action information only 810b050c 2581ffff Non redundant Insufficient Resources for RedundancySetElementName has deasserted Backup Memory This message is for the use case when a Redundancy Set has transitioned from Non redundant Insufficient Resources May also be shown as 81...

Страница 755: ...ically notify support No Alert Category Critical CPU SNMP Trap ID 40 CIM Information Prefix PLAT ID 0043 User Response No action information only 816f0007 0302ffff ProcessorElementName has Recovered from IERR CPU 2 This message is for the use case when an implementation has detected a Processor Recovered IERR Condition May also be shown as 816f00070302ffff or 0x816f00070302ffff Severity Info Servi...

Страница 756: ...tomatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0085 User Response No action information only 816f0008 0a02ffff PowerSupplyElementName has been removed from container PhysicalPackageElementName Power Supply 2 This message is for the use case when an implementation has detected a Power Supply has been removed May also be shown as 816f00080a02fff...

Страница 757: ...lert Category System Power On SNMP Trap ID 24 CIM Information Prefix PLAT ID 0107 User Response No action information only 816f000d 0400ffff The Drive StorageVolumeElementName has been removed from unit PhysicalPackageElementName Drive 0 This message is for the use case when an implementation has detected a Drive has been Removed May also be shown as 816f000d0400ffff or 0x816f000d0400ffff Severity...

Страница 758: ...00d0401ffff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0163 User Response 1 Reseat hard disk drive n n hard disk drive number Wait 1 minute or more before reinstalling the drive 2 Replace the hard disk drive 3 Make sure that the disk firmware and RAID controller firmware are at the latest leve...

Страница 759: ...3ffff The Drive StorageVolumeElementName has been removed from unit PhysicalPackageElementName Drive 3 This message is for the use case when an implementation has detected a Drive has been Removed May also be shown as 816f000d0403ffff or 0x816f000d0403ffff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PL...

Страница 760: ...IM Information Prefix PLAT ID 0163 User Response 1 Reseat hard disk drive n n hard disk drive number Wait 1 minute or more before reinstalling the drive 2 Replace the hard disk drive 3 Make sure that the disk firmware and RAID controller firmware are at the latest level 4 Check the SAS cable 816f000d 0405ffff The Drive StorageVolumeElementName has been removed from unit PhysicalPackageElementName ...

Страница 761: ...ay also be shown as 816f000d0406ffff or 0x816f000d0406ffff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0163 User Response 1 Reseat hard disk drive n n hard disk drive number Wait 1 minute or more before reinstalling the drive 2 Replace the hard disk drive 3 Make sure that the disk firmware and ...

Страница 762: ...isk firmware and RAID controller firmware are at the latest level 4 Check the SAS cable 816f000d 0408ffff The Drive StorageVolumeElementName has been removed from unit PhysicalPackageElementName Drive 8 This message is for the use case when an implementation has detected a Drive has been Removed May also be shown as 816f000d0408ffff or 0x816f000d0408ffff Severity Error Serviceable Yes Automaticall...

Страница 763: ...utomatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0163 User Response 1 Reseat hard disk drive n n hard disk drive number Wait 1 minute or more before reinstalling the drive 2 Replace the hard disk drive 3 Make sure that the disk firmware and RAID controller firmware are at the latest level 4 Check the SAS cable 816f000d 040affff Th...

Страница 764: ...PhysicalPackageElementName Drive 11 This message is for the use case when an implementation has detected a Drive has been Removed May also be shown as 816f000d040bffff or 0x816f000d040bffff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0163 User Response 1 Reseat hard disk drive n n hard disk dri...

Страница 765: ...k drive number Wait 1 minute or more before reinstalling the drive 2 Replace the hard disk drive 3 Make sure that the disk firmware and RAID controller firmware are at the latest level 4 Check the SAS cable 816f000d 040dffff The Drive StorageVolumeElementName has been removed from unit PhysicalPackageElementName Drive 13 This message is for the use case when an implementation has detected a Drive ...

Страница 766: ...everity Error Serviceable Yes Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0163 User Response 1 Reseat hard disk drive n n hard disk drive number Wait 1 minute or more before reinstalling the drive 2 Replace the hard disk drive 3 Make sure that the disk firmware and RAID controller firmware are at the latest level 4 Check the...

Страница 767: ... removed from unit PhysicalPackageElementName Drive 16 This message is for the use case when an implementation has detected a Drive has been Removed May also be shown as 816f000d0410ffff or 0x816f000d0410ffff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0163 User Response 1 Reseat hard disk driv...

Страница 768: ... hard disk drive n n hard disk drive number Wait 1 minute or more before reinstalling the drive 2 Replace the hard disk drive 3 Make sure that the disk firmware and RAID controller firmware are at the latest level 4 Check the SAS cable 816f000d 0412ffff The Drive StorageVolumeElementName has been removed from unit PhysicalPackageElementName Drive 18 This message is for the use case when an impleme...

Страница 769: ...16f000d0413ffff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0163 User Response 1 Reseat hard disk drive n n hard disk drive number Wait 1 minute or more before reinstalling the drive 2 Replace the hard disk drive 3 Make sure that the disk firmware and RAID controller firmware are at the latest ...

Страница 770: ...cable 816f000d 0415ffff The Drive StorageVolumeElementName has been removed from unit PhysicalPackageElementName Drive 21 This message is for the use case when an implementation has detected a Drive has been Removed May also be shown as 816f000d0415ffff or 0x816f000d0415ffff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM In...

Страница 771: ...ve SNMP Trap ID 5 CIM Information Prefix PLAT ID 0163 User Response 1 Reseat hard disk drive n n hard disk drive number Wait 1 minute or more before reinstalling the drive 2 Replace the hard disk drive 3 Make sure that the disk firmware and RAID controller firmware are at the latest level 4 Check the SAS cable 816f000d 0417ffff The Drive StorageVolumeElementName has been removed from unit Physical...

Страница 772: ...an implementation has detected a Drive has been Removed May also be shown as 816f000d0418ffff or 0x816f000d0418ffff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0163 User Response 1 Reseat hard disk drive n n hard disk drive number Wait 1 minute or more before reinstalling the drive 2 Replace th...

Страница 773: ...e the hard disk drive 3 Make sure that the disk firmware and RAID controller firmware are at the latest level 4 Check the SAS cable 816f000d 041affff The Drive StorageVolumeElementName has been removed from unit PhysicalPackageElementName Drive 26 This message is for the use case when an implementation has detected a Drive has been Removed May also be shown as 816f000d041affff or 0x816f000d041afff...

Страница 774: ...Yes Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0163 User Response 1 Reseat hard disk drive n n hard disk drive number Wait 1 minute or more before reinstalling the drive 2 Replace the hard disk drive 3 Make sure that the disk firmware and RAID controller firmware are at the latest level 4 Check the SAS cable 816f000d 041cff...

Страница 775: ...hysicalPackageElementName Drive 29 This message is for the use case when an implementation has detected a Drive has been Removed May also be shown as 816f000d041dffff or 0x816f000d041dffff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0163 User Response 1 Reseat hard disk drive n n hard disk driv...

Страница 776: ... n hard disk drive number Wait 1 minute or more before reinstalling the drive 2 Replace the hard disk drive 3 Make sure that the disk firmware and RAID controller firmware are at the latest level 4 Check the SAS cable 816f000d 041fffff The Drive StorageVolumeElementName has been removed from unit PhysicalPackageElementName Drive 31 This message is for the use case when an implementation has detect...

Страница 777: ...wn as 816f000f2201ffff or 0x816f000f2201ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Other SNMP Trap ID 50 CIM Information Prefix PLAT ID 0185 User Response If the specified sensor is one of the following ABR Status Firmware Error or Sys Boot Status No action information only 816f0013 1701ffff System ComputerSystemElementName has recovered from a diagno...

Страница 778: ...n as 816f00212201ffff or 0x816f00212201ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Other SNMP Trap ID 50 CIM Information Prefix PLAT ID 0331 User Response No action information only 816f0021 2582ffff Fault condition removed on slot PhysicalConnectorElementName on system ComputerSystemElementName All PCI Error This message is for the use case when an im...

Страница 779: ...ay also be shown as 816f00212c01ffff or 0x816f00212c01ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Other SNMP Trap ID 50 CIM Information Prefix PLAT ID 0331 User Response No action information only 816f0021 3001ffff Fault condition removed on slot PhysicalConnectorElementName on system ComputerSystemElementName PCI 1 This message is for the use case whe...

Страница 780: ...egraded unavailable failure May also be shown as 816f00282101ffff or 0x816f00282101ffff Severity Info Serviceable No Automatically notify support No Alert Category Warning Other SNMP Trap ID 60 CIM Information Prefix PLAT ID 0399 User Response No action information only 816f0107 0301ffff An Over Temperature Condition has been removed on ProcessorElementName CPU 1 This message is for the use case w...

Страница 781: ...Processor May also be shown as 816f01070302ffff or 0x816f01070302ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Temperature SNMP Trap ID 0 CIM Information Prefix PLAT ID 0037 User Response No action information only 816f0108 0a01ffff PowerSupplyElementName has returned to OK status Power Supply 1 This message is for the use case when an implementation has...

Страница 782: ...hown as 816f01080a02ffff or 0x816f01080a02ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Power SNMP Trap ID 4 CIM Information Prefix PLAT ID 0087 User Response No action information only 816f010c 2001ffff Uncorrectable error recovery detected for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 1 This message is for the use case when an imple...

Страница 783: ...ry May also be shown as 816f010c2002ffff or 0x816f010c2002ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0139 User Response No action information only 816f010c 2003ffff Uncorrectable error recovery detected for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 3 This message is for the use ...

Страница 784: ...r recovery May also be shown as 816f010c2004ffff or 0x816f010c2004ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0139 User Response No action information only 816f010c 2005ffff Uncorrectable error recovery detected for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 5 This message is for ...

Страница 785: ...ecovery May also be shown as 816f010c2006ffff or 0x816f010c2006ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0139 User Response No action information only 816f010c 2007ffff Uncorrectable error recovery detected for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 7 This message is for the...

Страница 786: ...r recovery May also be shown as 816f010c2008ffff or 0x816f010c2008ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0139 User Response No action information only 816f010c 2009ffff Uncorrectable error recovery detected for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 9 This message is for ...

Страница 787: ...ecovery May also be shown as 816f010c200affff or 0x816f010c200affff Severity Info Serviceable No Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0139 User Response No action information only 816f010c 200bffff Uncorrectable error recovery detected for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 11 This message is for th...

Страница 788: ...r recovery May also be shown as 816f010c200cffff or 0x816f010c200cffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0139 User Response No action information only 816f010c 200dffff Uncorrectable error recovery detected for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 13 This message is for...

Страница 789: ...ecovery May also be shown as 816f010c200effff or 0x816f010c200effff Severity Info Serviceable No Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0139 User Response No action information only 816f010c 200fffff Uncorrectable error recovery detected for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 15 This message is for th...

Страница 790: ...r recovery May also be shown as 816f010c2010ffff or 0x816f010c2010ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0139 User Response No action information only 816f010c 2011ffff Uncorrectable error recovery detected for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 17 This message is for...

Страница 791: ...ecovery May also be shown as 816f010c2012ffff or 0x816f010c2012ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0139 User Response No action information only 816f010c 2013ffff Uncorrectable error recovery detected for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 19 This message is for th...

Страница 792: ...r recovery May also be shown as 816f010c2014ffff or 0x816f010c2014ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0139 User Response No action information only 816f010c 2015ffff Uncorrectable error recovery detected for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 21 This message is for...

Страница 793: ...ecovery May also be shown as 816f010c2016ffff or 0x816f010c2016ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0139 User Response No action information only 816f010c 2017ffff Uncorrectable error recovery detected for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 23 This message is for th...

Страница 794: ... recovery May also be shown as 816f010c2018ffff or 0x816f010c2018ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0139 User Response No action information only 816f010c 2581ffff Uncorrectable error recovery detected for PhysicalMemoryElementName on Subsystem MemoryElementName All DIMMS This message is fo...

Страница 795: ...bled May also be shown as 816f010d0400ffff or 0x816f010d0400ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0167 User Response No action information only 816f010d 0401ffff The Drive StorageVolumeElementName has been enabled Drive 1 This message is for the use case when an implementation has dete...

Страница 796: ... shown as 816f010d0402ffff or 0x816f010d0402ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0167 User Response No action information only 816f010d 0403ffff The Drive StorageVolumeElementName has been enabled Drive 3 This message is for the use case when an implementation has detected a Drive was...

Страница 797: ... or 0x816f010d0404ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0167 User Response No action information only 816f010d 0405ffff The Drive StorageVolumeElementName has been enabled Drive 5 This message is for the use case when an implementation has detected a Drive was Enabled May also be shown...

Страница 798: ...nfo Serviceable No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0167 User Response No action information only 816f010d 0407ffff The Drive StorageVolumeElementName has been enabled Drive 7 This message is for the use case when an implementation has detected a Drive was Enabled May also be shown as 816f010d0407ffff or 0x816f010...

Страница 799: ...y notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0167 User Response No action information only 816f010d 0409ffff The Drive StorageVolumeElementName has been enabled Drive 9 This message is for the use case when an implementation has detected a Drive was Enabled May also be shown as 816f010d0409ffff or 0x816f010d0409ffff Severity Info Service...

Страница 800: ...ert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0167 User Response No action information only 816f010d 040bffff The Drive StorageVolumeElementName has been enabled Drive 11 This message is for the use case when an implementation has detected a Drive was Enabled May also be shown as 816f010d040bffff or 0x816f010d040bffff Severity Info Serviceable No Automatically...

Страница 801: ... Trap ID 5 CIM Information Prefix PLAT ID 0167 User Response No action information only 816f010d 040dffff The Drive StorageVolumeElementName has been enabled Drive 13 This message is for the use case when an implementation has detected a Drive was Enabled May also be shown as 816f010d040dffff or 0x816f010d040dffff Severity Info Serviceable No Automatically notify support No Alert Category Critical...

Страница 802: ...onse No action information only 816f010d 040fffff The Drive StorageVolumeElementName has been enabled Drive 15 This message is for the use case when an implementation has detected a Drive was Enabled May also be shown as 816f010d040fffff or 0x816f010d040fffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix P...

Страница 803: ...ssage is for the use case when an implementation has detected a Drive was Enabled May also be shown as 816f010d0411ffff or 0x816f010d0411ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0167 User Response No action information only 816f010d 0412ffff The Drive StorageVolumeElementName has been ena...

Страница 804: ...abled May also be shown as 816f010d0413ffff or 0x816f010d0413ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0167 User Response No action information only 816f010d 0414ffff The Drive StorageVolumeElementName has been enabled Drive 20 This message is for the use case when an implementation has de...

Страница 805: ...e shown as 816f010d0415ffff or 0x816f010d0415ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0167 User Response No action information only 816f010d 0416ffff The Drive StorageVolumeElementName has been enabled Drive 22 This message is for the use case when an implementation has detected a Drive w...

Страница 806: ...17ffff or 0x816f010d0417ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0167 User Response No action information only 816f010d 0418ffff The Drive StorageVolumeElementName has been enabled Drive 24 This message is for the use case when an implementation has detected a Drive was Enabled May also b...

Страница 807: ... Severity Info Serviceable No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0167 User Response No action information only 816f010d 041affff The Drive StorageVolumeElementName has been enabled Drive 26 This message is for the use case when an implementation has detected a Drive was Enabled May also be shown as 816f010d041affff ...

Страница 808: ...e No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0167 User Response No action information only 816f010d 041cffff The Drive StorageVolumeElementName has been enabled Drive 28 This message is for the use case when an implementation has detected a Drive was Enabled May also be shown as 816f010d041cffff or 0x816f010d041cffff Sev...

Страница 809: ...rt No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0167 User Response No action information only 816f010d 041effff The Drive StorageVolumeElementName has been enabled Drive 30 This message is for the use case when an implementation has detected a Drive was Enabled May also be shown as 816f010d041effff or 0x816f010d041effff Severity Info Serviceable No Autom...

Страница 810: ... Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0167 User Response No action information only 816f010f 2201ffff The System ComputerSystemElementName has recovered from a firmware hang Firmware Error This message is for the use case when an implementation has recovered from a System Firmware Hang May also be shown as 816f010f2201ffff or 0x816f010f2201ffff Severity Info Serviceable No...

Страница 811: ...Removing a microprocessor and heat sink and Replacing a microprocessor and heat sink 2 If the problem persists and there is no other CPU with the same error indication replace the system board 3 Trained technician only Replace the system board see Removing the system board and Installing the system board n microprocessor number 816f0113 0302ffff System ComputerSystemElementName has recovered from ...

Страница 812: ...ElementName configuration error has been repaired Front USB This message is for the use case when an implementation has detected an Interconnect Configuration was Repaired May also be shown as 816f011b0701ffff or 0x816f011b0701ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Other SNMP Trap ID 50 CIM Information Prefix PLAT ID 0267 User Response No action i...

Страница 813: ...Present May also be shown as 816f01251001ffff or 0x816f01251001ffff Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0390 User Response No action information only 816f0125 1002ffff ManagedElementName detected as present PCI Riser 2 This message is for the use case when an implementation has detected a Managed Eleme...

Страница 814: ...o be shown as 816f01252c01ffff or 0x816f01252c01ffff Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0390 User Response No action information only 816f0207 0301ffff ProcessorElementName has Recovered from FRB1 BIST condition CPU 1 This message is for the use case when an implementation has detected a Processor Rec...

Страница 815: ...lso be shown as 816f02070302ffff or 0x816f02070302ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical CPU SNMP Trap ID 40 CIM Information Prefix PLAT ID 0045 User Response No action information only 816f0207 2584ffff ProcessorElementName has Recovered from FRB1 BIST condition All CPUs This message is for the use case when an implementation has detected a Proce...

Страница 816: ... May also be shown as 816f020d0400ffff or 0x816f020d0400ffff Severity Info Serviceable No Automatically notify support No Alert Category System Predicted Failure SNMP Trap ID 27 CIM Information Prefix PLAT ID 0169 User Response No action information only 816f020d 0401ffff Failure no longer Predicted on drive StorageVolumeElementName for array ComputerSystemElementName Drive 1 This message is for t...

Страница 817: ...ed May also be shown as 816f020d0402ffff or 0x816f020d0402ffff Severity Info Serviceable No Automatically notify support No Alert Category System Predicted Failure SNMP Trap ID 27 CIM Information Prefix PLAT ID 0169 User Response No action information only 816f020d 0403ffff Failure no longer Predicted on drive StorageVolumeElementName for array ComputerSystemElementName Drive 3 This message is for...

Страница 818: ... Predicted May also be shown as 816f020d0404ffff or 0x816f020d0404ffff Severity Info Serviceable No Automatically notify support No Alert Category System Predicted Failure SNMP Trap ID 27 CIM Information Prefix PLAT ID 0169 User Response No action information only 816f020d 0405ffff Failure no longer Predicted on drive StorageVolumeElementName for array ComputerSystemElementName Drive 5 This messag...

Страница 819: ...edicted May also be shown as 816f020d0406ffff or 0x816f020d0406ffff Severity Info Serviceable No Automatically notify support No Alert Category System Predicted Failure SNMP Trap ID 27 CIM Information Prefix PLAT ID 0169 User Response No action information only 816f020d 0407ffff Failure no longer Predicted on drive StorageVolumeElementName for array ComputerSystemElementName Drive 7 This message i...

Страница 820: ... Predicted May also be shown as 816f020d0408ffff or 0x816f020d0408ffff Severity Info Serviceable No Automatically notify support No Alert Category System Predicted Failure SNMP Trap ID 27 CIM Information Prefix PLAT ID 0169 User Response No action information only 816f020d 0409ffff Failure no longer Predicted on drive StorageVolumeElementName for array ComputerSystemElementName Drive 9 This messag...

Страница 821: ...edicted May also be shown as 816f020d040affff or 0x816f020d040affff Severity Info Serviceable No Automatically notify support No Alert Category System Predicted Failure SNMP Trap ID 27 CIM Information Prefix PLAT ID 0169 User Response No action information only 816f020d 040bffff Failure no longer Predicted on drive StorageVolumeElementName for array ComputerSystemElementName Drive 11 This message ...

Страница 822: ... Predicted May also be shown as 816f020d040cffff or 0x816f020d040cffff Severity Info Serviceable No Automatically notify support No Alert Category System Predicted Failure SNMP Trap ID 27 CIM Information Prefix PLAT ID 0169 User Response No action information only 816f020d 040dffff Failure no longer Predicted on drive StorageVolumeElementName for array ComputerSystemElementName Drive 13 This messa...

Страница 823: ...edicted May also be shown as 816f020d040effff or 0x816f020d040effff Severity Info Serviceable No Automatically notify support No Alert Category System Predicted Failure SNMP Trap ID 27 CIM Information Prefix PLAT ID 0169 User Response No action information only 816f020d 040fffff Failure no longer Predicted on drive StorageVolumeElementName for array ComputerSystemElementName Drive 15 This message ...

Страница 824: ... Predicted May also be shown as 816f020d0410ffff or 0x816f020d0410ffff Severity Info Serviceable No Automatically notify support No Alert Category System Predicted Failure SNMP Trap ID 27 CIM Information Prefix PLAT ID 0169 User Response No action information only 816f020d 0411ffff Failure no longer Predicted on drive StorageVolumeElementName for array ComputerSystemElementName Drive 17 This messa...

Страница 825: ...edicted May also be shown as 816f020d0412ffff or 0x816f020d0412ffff Severity Info Serviceable No Automatically notify support No Alert Category System Predicted Failure SNMP Trap ID 27 CIM Information Prefix PLAT ID 0169 User Response No action information only 816f020d 0413ffff Failure no longer Predicted on drive StorageVolumeElementName for array ComputerSystemElementName Drive 19 This message ...

Страница 826: ... Predicted May also be shown as 816f020d0414ffff or 0x816f020d0414ffff Severity Info Serviceable No Automatically notify support No Alert Category System Predicted Failure SNMP Trap ID 27 CIM Information Prefix PLAT ID 0169 User Response No action information only 816f020d 0415ffff Failure no longer Predicted on drive StorageVolumeElementName for array ComputerSystemElementName Drive 21 This messa...

Страница 827: ...edicted May also be shown as 816f020d0416ffff or 0x816f020d0416ffff Severity Info Serviceable No Automatically notify support No Alert Category System Predicted Failure SNMP Trap ID 27 CIM Information Prefix PLAT ID 0169 User Response No action information only 816f020d 0417ffff Failure no longer Predicted on drive StorageVolumeElementName for array ComputerSystemElementName Drive 23 This message ...

Страница 828: ... Predicted May also be shown as 816f020d0418ffff or 0x816f020d0418ffff Severity Info Serviceable No Automatically notify support No Alert Category System Predicted Failure SNMP Trap ID 27 CIM Information Prefix PLAT ID 0169 User Response No action information only 816f020d 0419ffff Failure no longer Predicted on drive StorageVolumeElementName for array ComputerSystemElementName Drive 25 This messa...

Страница 829: ...edicted May also be shown as 816f020d041affff or 0x816f020d041affff Severity Info Serviceable No Automatically notify support No Alert Category System Predicted Failure SNMP Trap ID 27 CIM Information Prefix PLAT ID 0169 User Response No action information only 816f020d 041bffff Failure no longer Predicted on drive StorageVolumeElementName for array ComputerSystemElementName Drive 27 This message ...

Страница 830: ... Predicted May also be shown as 816f020d041cffff or 0x816f020d041cffff Severity Info Serviceable No Automatically notify support No Alert Category System Predicted Failure SNMP Trap ID 27 CIM Information Prefix PLAT ID 0169 User Response No action information only 816f020d 041dffff Failure no longer Predicted on drive StorageVolumeElementName for array ComputerSystemElementName Drive 29 This messa...

Страница 831: ...edicted May also be shown as 816f020d041effff or 0x816f020d041effff Severity Info Serviceable No Automatically notify support No Alert Category System Predicted Failure SNMP Trap ID 27 CIM Information Prefix PLAT ID 0169 User Response No action information only 816f020d 041fffff Failure no longer Predicted on drive StorageVolumeElementName for array ComputerSystemElementName Drive 31 This message ...

Страница 832: ...eturned to normal May also be shown as 816f03080a01ffff or 0x816f03080a01ffff Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0099 User Response No action information only 816f0308 0a02ffff PowerSupplyElementName has returned to a Normal Input State Power Supply 2 This message is for the use case when an implement...

Страница 833: ...May also be shown as 816f030c2001ffff or 0x816f030c2001ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0137 User Response No action information only 816f030c 2002ffff Scrub Failure for PhysicalMemoryElementName on Subsystem MemoryElementName has recovered DIMM 2 This message is for the use case when an ...

Страница 834: ...ay also be shown as 816f030c2003ffff or 0x816f030c2003ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0137 User Response No action information only 816f030c 2004ffff Scrub Failure for PhysicalMemoryElementName on Subsystem MemoryElementName has recovered DIMM 4 This message is for the use case when an i...

Страница 835: ...shown as 816f030c2005ffff or 0x816f030c2005ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0137 User Response No action information only 816f030c 2006ffff Scrub Failure for PhysicalMemoryElementName on Subsystem MemoryElementName has recovered DIMM 6 This message is for the use case when an implementati...

Страница 836: ... as 816f030c2007ffff or 0x816f030c2007ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0137 User Response No action information only 816f030c 2008ffff Scrub Failure for PhysicalMemoryElementName on Subsystem MemoryElementName has recovered DIMM 8 This message is for the use case when an implementation ha...

Страница 837: ...f or 0x816f030c2009ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0137 User Response No action information only 816f030c 200affff Scrub Failure for PhysicalMemoryElementName on Subsystem MemoryElementName has recovered DIMM 10 This message is for the use case when an implementation has detected a Memor...

Страница 838: ...0c200bffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0137 User Response No action information only 816f030c 200cffff Scrub Failure for PhysicalMemoryElementName on Subsystem MemoryElementName has recovered DIMM 12 This message is for the use case when an implementation has detected a Memory Scrub failu...

Страница 839: ...everity Info Serviceable No Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0137 User Response No action information only 816f030c 200effff Scrub Failure for PhysicalMemoryElementName on Subsystem MemoryElementName has recovered DIMM 14 This message is for the use case when an implementation has detected a Memory Scrub failure recovery ...

Страница 840: ... Serviceable No Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0137 User Response No action information only 816f030c 2010ffff Scrub Failure for PhysicalMemoryElementName on Subsystem MemoryElementName has recovered DIMM 16 This message is for the use case when an implementation has detected a Memory Scrub failure recovery May also be ...

Страница 841: ...tomatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0137 User Response No action information only 816f030c 2012ffff Scrub Failure for PhysicalMemoryElementName on Subsystem MemoryElementName has recovered DIMM 18 This message is for the use case when an implementation has detected a Memory Scrub failure recovery May also be shown as 816f030c2...

Страница 842: ...ically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0137 User Response No action information only 816f030c 2014ffff Scrub Failure for PhysicalMemoryElementName on Subsystem MemoryElementName has recovered DIMM 20 This message is for the use case when an implementation has detected a Memory Scrub failure recovery May also be shown as 816f030c2014ff...

Страница 843: ...y support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0137 User Response No action information only 816f030c 2016ffff Scrub Failure for PhysicalMemoryElementName on Subsystem MemoryElementName has recovered DIMM 22 This message is for the use case when an implementation has detected a Memory Scrub failure recovery May also be shown as 816f030c2016ffff or 0x816f...

Страница 844: ...ert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0137 User Response No action information only 816f030c 2018ffff Scrub Failure for PhysicalMemoryElementName on Subsystem MemoryElementName has recovered DIMM 24 This message is for the use case when an implementation has detected a Memory Scrub failure recovery May also be shown as 816f030c2018ffff or 0x816f030c2018ffff Se...

Страница 845: ...tegory Critical Other SNMP Trap ID 50 CIM Information Prefix PLAT ID 0230 User Response No action information only 816f040c 2001ffff PhysicalMemoryElementName Enabled on Subsystem MemoryElementName DIMM 1 This message is for the use case when an implementation has detected that Memory has been Enabled May also be shown as 816f040c2001ffff or 0x816f040c2001ffff Severity Info Serviceable No Automati...

Страница 846: ...y System Other SNMP Trap ID CIM Information Prefix PLAT ID 0130 User Response No action information only 816f040c 2003ffff PhysicalMemoryElementName Enabled on Subsystem MemoryElementName DIMM 3 This message is for the use case when an implementation has detected that Memory has been Enabled May also be shown as 816f040c2003ffff or 0x816f040c2003ffff Severity Info Serviceable No Automatically noti...

Страница 847: ... ID CIM Information Prefix PLAT ID 0130 User Response No action information only 816f040c 2005ffff PhysicalMemoryElementName Enabled on Subsystem MemoryElementName DIMM 5 This message is for the use case when an implementation has detected that Memory has been Enabled May also be shown as 816f040c2005ffff or 0x816f040c2005ffff Severity Info Serviceable No Automatically notify support No Alert Cate...

Страница 848: ...formation Prefix PLAT ID 0130 User Response No action information only 816f040c 2007ffff PhysicalMemoryElementName Enabled on Subsystem MemoryElementName DIMM 7 This message is for the use case when an implementation has detected that Memory has been Enabled May also be shown as 816f040c2007ffff or 0x816f040c2007ffff Severity Info Serviceable No Automatically notify support No Alert Category Syste...

Страница 849: ...mation Prefix PLAT ID 0130 User Response No action information only 816f040c 2009ffff PhysicalMemoryElementName Enabled on Subsystem MemoryElementName DIMM 9 This message is for the use case when an implementation has detected that Memory has been Enabled May also be shown as 816f040c2009ffff or 0x816f040c2009ffff Severity Info Serviceable No Automatically notify support No Alert Category System O...

Страница 850: ...formation Prefix PLAT ID 0130 User Response No action information only 816f040c 200bffff PhysicalMemoryElementName Enabled on Subsystem MemoryElementName DIMM 11 This message is for the use case when an implementation has detected that Memory has been Enabled May also be shown as 816f040c200bffff or 0x816f040c200bffff Severity Info Serviceable No Automatically notify support No Alert Category Syst...

Страница 851: ...mation Prefix PLAT ID 0130 User Response No action information only 816f040c 200dffff PhysicalMemoryElementName Enabled on Subsystem MemoryElementName DIMM 13 This message is for the use case when an implementation has detected that Memory has been Enabled May also be shown as 816f040c200dffff or 0x816f040c200dffff Severity Info Serviceable No Automatically notify support No Alert Category System ...

Страница 852: ...formation Prefix PLAT ID 0130 User Response No action information only 816f040c 200fffff PhysicalMemoryElementName Enabled on Subsystem MemoryElementName DIMM 15 This message is for the use case when an implementation has detected that Memory has been Enabled May also be shown as 816f040c200fffff or 0x816f040c200fffff Severity Info Serviceable No Automatically notify support No Alert Category Syst...

Страница 853: ...mation Prefix PLAT ID 0130 User Response No action information only 816f040c 2011ffff PhysicalMemoryElementName Enabled on Subsystem MemoryElementName DIMM 17 This message is for the use case when an implementation has detected that Memory has been Enabled May also be shown as 816f040c2011ffff or 0x816f040c2011ffff Severity Info Serviceable No Automatically notify support No Alert Category System ...

Страница 854: ...formation Prefix PLAT ID 0130 User Response No action information only 816f040c 2013ffff PhysicalMemoryElementName Enabled on Subsystem MemoryElementName DIMM 19 This message is for the use case when an implementation has detected that Memory has been Enabled May also be shown as 816f040c2013ffff or 0x816f040c2013ffff Severity Info Serviceable No Automatically notify support No Alert Category Syst...

Страница 855: ...mation Prefix PLAT ID 0130 User Response No action information only 816f040c 2015ffff PhysicalMemoryElementName Enabled on Subsystem MemoryElementName DIMM 21 This message is for the use case when an implementation has detected that Memory has been Enabled May also be shown as 816f040c2015ffff or 0x816f040c2015ffff Severity Info Serviceable No Automatically notify support No Alert Category System ...

Страница 856: ...formation Prefix PLAT ID 0130 User Response No action information only 816f040c 2017ffff PhysicalMemoryElementName Enabled on Subsystem MemoryElementName DIMM 23 This message is for the use case when an implementation has detected that Memory has been Enabled May also be shown as 816f040c2017ffff or 0x816f040c2017ffff Severity Info Serviceable No Automatically notify support No Alert Category Syst...

Страница 857: ...efix PLAT ID 0130 User Response No action information only 816f040c 2581ffff PhysicalMemoryElementName Enabled on Subsystem MemoryElementName All DIMMS This message is for the use case when an implementation has detected that Memory has been Enabled May also be shown as 816f040c2581ffff or 0x816f040c2581ffff Severity Info Serviceable No Automatically notify support No Alert Category System Other S...

Страница 858: ...on Prefix PLAT ID 0233 User Response No action information only 816f0507 0301ffff ProcessorElementName has Recovered from a Configuration Mismatch CPU 1 This message is for the use case when an implementation has Recovered from a Processor Configuration Mismatch May also be shown as 816f05070301ffff or 0x816f05070301ffff Severity Info Serviceable No Automatically notify support No Alert Category C...

Страница 859: ...efix PLAT ID 0063 User Response No action information only 816f0507 2584ffff ProcessorElementName has Recovered from a Configuration Mismatch All CPUs This message is for the use case when an implementation has Recovered from a Processor Configuration Mismatch May also be shown as 816f05072584ffff or 0x816f05072584ffff Severity Info Serviceable No Automatically notify support No Alert Category Cri...

Страница 860: ...formation Prefix PLAT ID 0145 User Response No action information only 816f050c 2002ffff Memory Logging Limit Removed for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 2 This message is for the use case when an implementation has detected that the Memory Logging Limit has been Removed May also be shown as 816f050c2002ffff or 0x816f050c2002ffff Severity Info Serviceable No Automatic...

Страница 861: ...mation Prefix PLAT ID 0145 User Response No action information only 816f050c 2004ffff Memory Logging Limit Removed for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 4 This message is for the use case when an implementation has detected that the Memory Logging Limit has been Removed May also be shown as 816f050c2004ffff or 0x816f050c2004ffff Severity Info Serviceable No Automaticall...

Страница 862: ...formation Prefix PLAT ID 0145 User Response No action information only 816f050c 2006ffff Memory Logging Limit Removed for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 6 This message is for the use case when an implementation has detected that the Memory Logging Limit has been Removed May also be shown as 816f050c2006ffff or 0x816f050c2006ffff Severity Info Serviceable No Automatic...

Страница 863: ...mation Prefix PLAT ID 0145 User Response No action information only 816f050c 2008ffff Memory Logging Limit Removed for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 8 This message is for the use case when an implementation has detected that the Memory Logging Limit has been Removed May also be shown as 816f050c2008ffff or 0x816f050c2008ffff Severity Info Serviceable No Automaticall...

Страница 864: ...formation Prefix PLAT ID 0145 User Response No action information only 816f050c 200affff Memory Logging Limit Removed for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 10 This message is for the use case when an implementation has detected that the Memory Logging Limit has been Removed May also be shown as 816f050c200affff or 0x816f050c200affff Severity Info Serviceable No Automati...

Страница 865: ...mation Prefix PLAT ID 0145 User Response No action information only 816f050c 200cffff Memory Logging Limit Removed for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 12 This message is for the use case when an implementation has detected that the Memory Logging Limit has been Removed May also be shown as 816f050c200cffff or 0x816f050c200cffff Severity Info Serviceable No Automatical...

Страница 866: ...formation Prefix PLAT ID 0145 User Response No action information only 816f050c 200effff Memory Logging Limit Removed for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 14 This message is for the use case when an implementation has detected that the Memory Logging Limit has been Removed May also be shown as 816f050c200effff or 0x816f050c200effff Severity Info Serviceable No Automati...

Страница 867: ...mation Prefix PLAT ID 0145 User Response No action information only 816f050c 2010ffff Memory Logging Limit Removed for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 16 This message is for the use case when an implementation has detected that the Memory Logging Limit has been Removed May also be shown as 816f050c2010ffff or 0x816f050c2010ffff Severity Info Serviceable No Automatical...

Страница 868: ...formation Prefix PLAT ID 0145 User Response No action information only 816f050c 2012ffff Memory Logging Limit Removed for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 18 This message is for the use case when an implementation has detected that the Memory Logging Limit has been Removed May also be shown as 816f050c2012ffff or 0x816f050c2012ffff Severity Info Serviceable No Automati...

Страница 869: ...mation Prefix PLAT ID 0145 User Response No action information only 816f050c 2014ffff Memory Logging Limit Removed for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 20 This message is for the use case when an implementation has detected that the Memory Logging Limit has been Removed May also be shown as 816f050c2014ffff or 0x816f050c2014ffff Severity Info Serviceable No Automatical...

Страница 870: ...formation Prefix PLAT ID 0145 User Response No action information only 816f050c 2016ffff Memory Logging Limit Removed for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 22 This message is for the use case when an implementation has detected that the Memory Logging Limit has been Removed May also be shown as 816f050c2016ffff or 0x816f050c2016ffff Severity Info Serviceable No Automati...

Страница 871: ...mation Prefix PLAT ID 0145 User Response No action information only 816f050c 2018ffff Memory Logging Limit Removed for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 24 This message is for the use case when an implementation has detected that the Memory Logging Limit has been Removed May also be shown as 816f050c2018ffff or 0x816f050c2018ffff Severity Info Serviceable No Automatical...

Страница 872: ...43 CIM Information Prefix PLAT ID 0145 User Response No action information only One of the DIMMs 816f050d 0400ffff Critical Array ComputerSystemElementName has deasserted Drive 0 This message is for the use case when an implementation has detected that an Critiacal Array has deasserted May also be shown as 816f050d0400ffff or 0x816f050d0400ffff Severity Info Serviceable No Automatically notify sup...

Страница 873: ...mation Prefix PLAT ID 0175 User Response No action information only 816f050d 0402ffff Critical Array ComputerSystemElementName has deasserted Drive 2 This message is for the use case when an implementation has detected that an Critiacal Array has deasserted May also be shown as 816f050d0402ffff or 0x816f050d0402ffff Severity Info Serviceable No Automatically notify support No Alert Category Critic...

Страница 874: ...se No action information only 816f050d 0404ffff Critical Array ComputerSystemElementName has deasserted Drive 4 This message is for the use case when an implementation has detected that an Critiacal Array has deasserted May also be shown as 816f050d0404ffff or 0x816f050d0404ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM ...

Страница 875: ...fff Critical Array ComputerSystemElementName has deasserted Drive 6 This message is for the use case when an implementation has detected that an Critiacal Array has deasserted May also be shown as 816f050d0406ffff or 0x816f050d0406ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0175 User Respons...

Страница 876: ...08ffff Critical Array ComputerSystemElementName has deasserted Drive 8 This message is for the use case when an implementation has detected that an Critiacal Array has deasserted May also be shown as 816f050d0408ffff or 0x816f050d0408ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0175 User Resp...

Страница 877: ...ff Critical Array ComputerSystemElementName has deasserted Drive 10 This message is for the use case when an implementation has detected that an Critiacal Array has deasserted May also be shown as 816f050d040affff or 0x816f050d040affff Severity Info Serviceable No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0175 User Respons...

Страница 878: ...cffff Critical Array ComputerSystemElementName has deasserted Drive 12 This message is for the use case when an implementation has detected that an Critiacal Array has deasserted May also be shown as 816f050d040cffff or 0x816f050d040cffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0175 User Resp...

Страница 879: ...ff Critical Array ComputerSystemElementName has deasserted Drive 14 This message is for the use case when an implementation has detected that an Critiacal Array has deasserted May also be shown as 816f050d040effff or 0x816f050d040effff Severity Info Serviceable No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0175 User Respons...

Страница 880: ...0ffff Critical Array ComputerSystemElementName has deasserted Drive 16 This message is for the use case when an implementation has detected that an Critiacal Array has deasserted May also be shown as 816f050d0410ffff or 0x816f050d0410ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0175 User Resp...

Страница 881: ...ff Critical Array ComputerSystemElementName has deasserted Drive 18 This message is for the use case when an implementation has detected that an Critiacal Array has deasserted May also be shown as 816f050d0412ffff or 0x816f050d0412ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0175 User Respons...

Страница 882: ...4ffff Critical Array ComputerSystemElementName has deasserted Drive 20 This message is for the use case when an implementation has detected that an Critiacal Array has deasserted May also be shown as 816f050d0414ffff or 0x816f050d0414ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0175 User Resp...

Страница 883: ...ff Critical Array ComputerSystemElementName has deasserted Drive 22 This message is for the use case when an implementation has detected that an Critiacal Array has deasserted May also be shown as 816f050d0416ffff or 0x816f050d0416ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0175 User Respons...

Страница 884: ...8ffff Critical Array ComputerSystemElementName has deasserted Drive 24 This message is for the use case when an implementation has detected that an Critiacal Array has deasserted May also be shown as 816f050d0418ffff or 0x816f050d0418ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0175 User Resp...

Страница 885: ...ff Critical Array ComputerSystemElementName has deasserted Drive 26 This message is for the use case when an implementation has detected that an Critiacal Array has deasserted May also be shown as 816f050d041affff or 0x816f050d041affff Severity Info Serviceable No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0175 User Respons...

Страница 886: ...cffff Critical Array ComputerSystemElementName has deasserted Drive 28 This message is for the use case when an implementation has detected that an Critiacal Array has deasserted May also be shown as 816f050d041cffff or 0x816f050d041cffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0175 User Resp...

Страница 887: ...ff Critical Array ComputerSystemElementName has deasserted Drive 30 This message is for the use case when an implementation has detected that an Critiacal Array has deasserted May also be shown as 816f050d041effff or 0x816f050d041effff Severity Info Serviceable No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0175 User Respons...

Страница 888: ...IOS Uncorrectable CPU complex error for ProcessorElementName has deasserted CPU 1 This message is for the use case when an SM BIOS Uncorrectable CPU complex error has deasserted May also be shown as 816f06070301ffff or 0x816f06070301ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical CPU SNMP Trap ID 40 CIM Information Prefix PLAT ID 0817 User Response No acti...

Страница 889: ...ame has deasserted All CPUs This message is for the use case when an SM BIOS Uncorrectable CPU complex error has deasserted May also be shown as 816f06072584ffff or 0x816f06072584ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical CPU SNMP Trap ID 40 CIM Information Prefix PLAT ID 0817 User Response No action information only One of the CPUs 816f0608 1301ffff ...

Страница 890: ...at a Failed Array has been Restored May also be shown as 816f060d0400ffff or 0x816f060d0400ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0177 User Response No action information only 816f060d 0401ffff Array in system ComputerSystemElementName has been restored Drive 1 This message is for the u...

Страница 891: ...estored May also be shown as 816f060d0402ffff or 0x816f060d0402ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0177 User Response No action information only 816f060d 0403ffff Array in system ComputerSystemElementName has been restored Drive 3 This message is for the use case when an implementati...

Страница 892: ...tored May also be shown as 816f060d0404ffff or 0x816f060d0404ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0177 User Response No action information only 816f060d 0405ffff Array in system ComputerSystemElementName has been restored Drive 5 This message is for the use case when an implementation...

Страница 893: ...also be shown as 816f060d0406ffff or 0x816f060d0406ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0177 User Response No action information only 816f060d 0407ffff Array in system ComputerSystemElementName has been restored Drive 7 This message is for the use case when an implementation has detec...

Страница 894: ...be shown as 816f060d0408ffff or 0x816f060d0408ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0177 User Response No action information only 816f060d 0409ffff Array in system ComputerSystemElementName has been restored Drive 9 This message is for the use case when an implementation has detected t...

Страница 895: ... 816f060d040affff or 0x816f060d040affff Severity Info Serviceable No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0177 User Response No action information only 816f060d 040bffff Array in system ComputerSystemElementName has been restored Drive 11 This message is for the use case when an implementation has detected that a Fail...

Страница 896: ...ffff or 0x816f060d040cffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0177 User Response No action information only 816f060d 040dffff Array in system ComputerSystemElementName has been restored Drive 13 This message is for the use case when an implementation has detected that a Failed Array has ...

Страница 897: ...40effff Severity Info Serviceable No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0177 User Response No action information only 816f060d 040fffff Array in system ComputerSystemElementName has been restored Drive 15 This message is for the use case when an implementation has detected that a Failed Array has been Restored May a...

Страница 898: ...f Severity Info Serviceable No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0177 User Response No action information only 816f060d 0411ffff Array in system ComputerSystemElementName has been restored Drive 17 This message is for the use case when an implementation has detected that a Failed Array has been Restored May also be...

Страница 899: ...able No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0177 User Response No action information only 816f060d 0413ffff Array in system ComputerSystemElementName has been restored Drive 19 This message is for the use case when an implementation has detected that a Failed Array has been Restored May also be shown as 816f060d0413f...

Страница 900: ...cally notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0177 User Response No action information only 816f060d 0415ffff Array in system ComputerSystemElementName has been restored Drive 21 This message is for the use case when an implementation has detected that a Failed Array has been Restored May also be shown as 816f060d0415ffff or 0x816f060...

Страница 901: ...fy support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0177 User Response No action information only 816f060d 0417ffff Array in system ComputerSystemElementName has been restored Drive 23 This message is for the use case when an implementation has detected that a Failed Array has been Restored May also be shown as 816f060d0417ffff or 0x816f060d0417ffff ...

Страница 902: ...port No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0177 User Response No action information only 816f060d 0419ffff Array in system ComputerSystemElementName has been restored Drive 25 This message is for the use case when an implementation has detected that a Failed Array has been Restored May also be shown as 816f060d0419ffff or 0x816f060d0419ffff Severi...

Страница 903: ...y Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0177 User Response No action information only 816f060d 041bffff Array in system ComputerSystemElementName has been restored Drive 27 This message is for the use case when an implementation has detected that a Failed Array has been Restored May also be shown as 816f060d041bffff or 0x816f060d041bffff Severity Info Serviceable N...

Страница 904: ...d Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0177 User Response No action information only 816f060d 041dffff Array in system ComputerSystemElementName has been restored Drive 29 This message is for the use case when an implementation has detected that a Failed Array has been Restored May also be shown as 816f060d041dffff or 0x816f060d041dffff Severity Info Serviceable No Automaticall...

Страница 905: ...D 5 CIM Information Prefix PLAT ID 0177 User Response No action information only 816f060d 041fffff Array in system ComputerSystemElementName has been restored Drive 31 This message is for the use case when an implementation has detected that a Failed Array has been Restored May also be shown as 816f060d041fffff or 0x816f060d041fffff Severity Info Serviceable No Automatically notify support No Aler...

Страница 906: ...formation Prefix PLAT ID 0127 User Response No action information only 816f070c 2002ffff Configuration error for PhysicalMemoryElementName on Subsystem MemoryElementName has deasserted DIMM 2 This message is for the use case when an implementation has detected a Memory DIMM configuration error has deasserted May also be shown as 816f070c2002ffff or 0x816f070c2002ffff Severity Info Serviceable No A...

Страница 907: ...mation Prefix PLAT ID 0127 User Response No action information only 816f070c 2004ffff Configuration error for PhysicalMemoryElementName on Subsystem MemoryElementName has deasserted DIMM 4 This message is for the use case when an implementation has detected a Memory DIMM configuration error has deasserted May also be shown as 816f070c2004ffff or 0x816f070c2004ffff Severity Info Serviceable No Auto...

Страница 908: ...formation Prefix PLAT ID 0127 User Response No action information only 816f070c 2006ffff Configuration error for PhysicalMemoryElementName on Subsystem MemoryElementName has deasserted DIMM 6 This message is for the use case when an implementation has detected a Memory DIMM configuration error has deasserted May also be shown as 816f070c2006ffff or 0x816f070c2006ffff Severity Info Serviceable No A...

Страница 909: ...mation Prefix PLAT ID 0127 User Response No action information only 816f070c 2008ffff Configuration error for PhysicalMemoryElementName on Subsystem MemoryElementName has deasserted DIMM 8 This message is for the use case when an implementation has detected a Memory DIMM configuration error has deasserted May also be shown as 816f070c2008ffff or 0x816f070c2008ffff Severity Info Serviceable No Auto...

Страница 910: ...formation Prefix PLAT ID 0127 User Response No action information only 816f070c 200affff Configuration error for PhysicalMemoryElementName on Subsystem MemoryElementName has deasserted DIMM 10 This message is for the use case when an implementation has detected a Memory DIMM configuration error has deasserted May also be shown as 816f070c200affff or 0x816f070c200affff Severity Info Serviceable No ...

Страница 911: ...mation Prefix PLAT ID 0127 User Response No action information only 816f070c 200cffff Configuration error for PhysicalMemoryElementName on Subsystem MemoryElementName has deasserted DIMM 12 This message is for the use case when an implementation has detected a Memory DIMM configuration error has deasserted May also be shown as 816f070c200cffff or 0x816f070c200cffff Severity Info Serviceable No Aut...

Страница 912: ...formation Prefix PLAT ID 0127 User Response No action information only 816f070c 200effff Configuration error for PhysicalMemoryElementName on Subsystem MemoryElementName has deasserted DIMM 14 This message is for the use case when an implementation has detected a Memory DIMM configuration error has deasserted May also be shown as 816f070c200effff or 0x816f070c200effff Severity Info Serviceable No ...

Страница 913: ...mation Prefix PLAT ID 0127 User Response No action information only 816f070c 2010ffff Configuration error for PhysicalMemoryElementName on Subsystem MemoryElementName has deasserted DIMM 16 This message is for the use case when an implementation has detected a Memory DIMM configuration error has deasserted May also be shown as 816f070c2010ffff or 0x816f070c2010ffff Severity Info Serviceable No Aut...

Страница 914: ...formation Prefix PLAT ID 0127 User Response No action information only 816f070c 2012ffff Configuration error for PhysicalMemoryElementName on Subsystem MemoryElementName has deasserted DIMM 18 This message is for the use case when an implementation has detected a Memory DIMM configuration error has deasserted May also be shown as 816f070c2012ffff or 0x816f070c2012ffff Severity Info Serviceable No ...

Страница 915: ...mation Prefix PLAT ID 0127 User Response No action information only 816f070c 2014ffff Configuration error for PhysicalMemoryElementName on Subsystem MemoryElementName has deasserted DIMM 20 This message is for the use case when an implementation has detected a Memory DIMM configuration error has deasserted May also be shown as 816f070c2014ffff or 0x816f070c2014ffff Severity Info Serviceable No Aut...

Страница 916: ...formation Prefix PLAT ID 0127 User Response No action information only 816f070c 2016ffff Configuration error for PhysicalMemoryElementName on Subsystem MemoryElementName has deasserted DIMM 22 This message is for the use case when an implementation has detected a Memory DIMM configuration error has deasserted May also be shown as 816f070c2016ffff or 0x816f070c2016ffff Severity Info Serviceable No ...

Страница 917: ...mation Prefix PLAT ID 0127 User Response No action information only 816f070c 2018ffff Configuration error for PhysicalMemoryElementName on Subsystem MemoryElementName has deasserted DIMM 24 This message is for the use case when an implementation has detected a Memory DIMM configuration error has deasserted May also be shown as 816f070c2018ffff or 0x816f070c2018ffff Severity Info Serviceable No Aut...

Страница 918: ... Trap ID 41 CIM Information Prefix PLAT ID 0127 User Response No action information only One of the DIMMs 816f070d 0400ffff Rebuild completed for Array in system ComputerSystemElementName Drive 0 This message is for the use case when an implementation has detected that an Array Rebuild has Completed May also be shown as 816f070d0400ffff or 0x816f070d0400ffff Severity Info Serviceable No Automatica...

Страница 919: ...mation Prefix PLAT ID 0179 User Response No action information only 816f070d 0402ffff Rebuild completed for Array in system ComputerSystemElementName Drive 2 This message is for the use case when an implementation has detected that an Array Rebuild has Completed May also be shown as 816f070d0402ffff or 0x816f070d0402ffff Severity Info Serviceable No Automatically notify support No Alert Category S...

Страница 920: ...formation Prefix PLAT ID 0179 User Response No action information only 816f070d 0404ffff Rebuild completed for Array in system ComputerSystemElementName Drive 4 This message is for the use case when an implementation has detected that an Array Rebuild has Completed May also be shown as 816f070d0404ffff or 0x816f070d0404ffff Severity Info Serviceable No Automatically notify support No Alert Categor...

Страница 921: ...mation Prefix PLAT ID 0179 User Response No action information only 816f070d 0406ffff Rebuild completed for Array in system ComputerSystemElementName Drive 6 This message is for the use case when an implementation has detected that an Array Rebuild has Completed May also be shown as 816f070d0406ffff or 0x816f070d0406ffff Severity Info Serviceable No Automatically notify support No Alert Category S...

Страница 922: ...formation Prefix PLAT ID 0179 User Response No action information only 816f070d 0408ffff Rebuild completed for Array in system ComputerSystemElementName Drive 8 This message is for the use case when an implementation has detected that an Array Rebuild has Completed May also be shown as 816f070d0408ffff or 0x816f070d0408ffff Severity Info Serviceable No Automatically notify support No Alert Categor...

Страница 923: ...mation Prefix PLAT ID 0179 User Response No action information only 816f070d 040affff Rebuild completed for Array in system ComputerSystemElementName Drive 10 This message is for the use case when an implementation has detected that an Array Rebuild has Completed May also be shown as 816f070d040affff or 0x816f070d040affff Severity Info Serviceable No Automatically notify support No Alert Category ...

Страница 924: ...formation Prefix PLAT ID 0179 User Response No action information only 816f070d 040cffff Rebuild completed for Array in system ComputerSystemElementName Drive 12 This message is for the use case when an implementation has detected that an Array Rebuild has Completed May also be shown as 816f070d040cffff or 0x816f070d040cffff Severity Info Serviceable No Automatically notify support No Alert Catego...

Страница 925: ...mation Prefix PLAT ID 0179 User Response No action information only 816f070d 040effff Rebuild completed for Array in system ComputerSystemElementName Drive 14 This message is for the use case when an implementation has detected that an Array Rebuild has Completed May also be shown as 816f070d040effff or 0x816f070d040effff Severity Info Serviceable No Automatically notify support No Alert Category ...

Страница 926: ...formation Prefix PLAT ID 0179 User Response No action information only 816f070d 0410ffff Rebuild completed for Array in system ComputerSystemElementName Drive 16 This message is for the use case when an implementation has detected that an Array Rebuild has Completed May also be shown as 816f070d0410ffff or 0x816f070d0410ffff Severity Info Serviceable No Automatically notify support No Alert Catego...

Страница 927: ...mation Prefix PLAT ID 0179 User Response No action information only 816f070d 0412ffff Rebuild completed for Array in system ComputerSystemElementName Drive 18 This message is for the use case when an implementation has detected that an Array Rebuild has Completed May also be shown as 816f070d0412ffff or 0x816f070d0412ffff Severity Info Serviceable No Automatically notify support No Alert Category ...

Страница 928: ...formation Prefix PLAT ID 0179 User Response No action information only 816f070d 0414ffff Rebuild completed for Array in system ComputerSystemElementName Drive 20 This message is for the use case when an implementation has detected that an Array Rebuild has Completed May also be shown as 816f070d0414ffff or 0x816f070d0414ffff Severity Info Serviceable No Automatically notify support No Alert Catego...

Страница 929: ...mation Prefix PLAT ID 0179 User Response No action information only 816f070d 0416ffff Rebuild completed for Array in system ComputerSystemElementName Drive 22 This message is for the use case when an implementation has detected that an Array Rebuild has Completed May also be shown as 816f070d0416ffff or 0x816f070d0416ffff Severity Info Serviceable No Automatically notify support No Alert Category ...

Страница 930: ...formation Prefix PLAT ID 0179 User Response No action information only 816f070d 0418ffff Rebuild completed for Array in system ComputerSystemElementName Drive 24 This message is for the use case when an implementation has detected that an Array Rebuild has Completed May also be shown as 816f070d0418ffff or 0x816f070d0418ffff Severity Info Serviceable No Automatically notify support No Alert Catego...

Страница 931: ...mation Prefix PLAT ID 0179 User Response No action information only 816f070d 041affff Rebuild completed for Array in system ComputerSystemElementName Drive 26 This message is for the use case when an implementation has detected that an Array Rebuild has Completed May also be shown as 816f070d041affff or 0x816f070d041affff Severity Info Serviceable No Automatically notify support No Alert Category ...

Страница 932: ...formation Prefix PLAT ID 0179 User Response No action information only 816f070d 041cffff Rebuild completed for Array in system ComputerSystemElementName Drive 28 This message is for the use case when an implementation has detected that an Array Rebuild has Completed May also be shown as 816f070d041cffff or 0x816f070d041cffff Severity Info Serviceable No Automatically notify support No Alert Catego...

Страница 933: ...mation Prefix PLAT ID 0179 User Response No action information only 816f070d 041effff Rebuild completed for Array in system ComputerSystemElementName Drive 30 This message is for the use case when an implementation has detected that an Array Rebuild has Completed May also be shown as 816f070d041effff or 0x816f070d041effff Severity Info Serviceable No Automatically notify support No Alert Category ...

Страница 934: ...NMP Trap ID CIM Information Prefix PLAT ID 0179 User Response No action information only 816f0807 0301ffff ProcessorElementName has been Enabled CPU 1 This message is for the use case when an implementation has detected a Processor has been Enabled May also be shown as 816f08070301ffff or 0x816f08070301ffff Severity Info Serviceable No Automatically notify support No Alert Category System Other SN...

Страница 935: ...n only 816f0807 2584ffff ProcessorElementName has been Enabled All CPUs This message is for the use case when an implementation has detected a Processor has been Enabled May also be shown as 816f08072584ffff or 0x816f08072584ffff Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0060 User Response No action informat...

Страница 936: ...on information only 816f0813 2582ffff System ComputerSystemElementName has recovered from an Uncorrectable Bus Error PCIs This message is for the use case when an implementation has detected a that a system has recovered from a Bus Uncorrectable Error May also be shown as 816f08132582ffff or 0x816f08132582ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Oth...

Страница 937: ...p ID 50 CIM Information Prefix PLAT ID 0241 User Response No action information only 816f090c 2001ffff PhysicalMemoryElementName on Subsystem MemoryElementName is no longer Throttled DIMM 1 This message is for the use case when an implementation has detected Memory is no longer Throttled May also be shown as 816f090c2001ffff or 0x816f090c2001ffff Severity Info Serviceable No Automatically notify s...

Страница 938: ...formation Prefix PLAT ID 0143 User Response No action information only 816f090c 2003ffff PhysicalMemoryElementName on Subsystem MemoryElementName is no longer Throttled DIMM 3 This message is for the use case when an implementation has detected Memory is no longer Throttled May also be shown as 816f090c2003ffff or 0x816f090c2003ffff Severity Info Serviceable No Automatically notify support No Aler...

Страница 939: ...mation Prefix PLAT ID 0143 User Response No action information only 816f090c 2005ffff PhysicalMemoryElementName on Subsystem MemoryElementName is no longer Throttled DIMM 5 This message is for the use case when an implementation has detected Memory is no longer Throttled May also be shown as 816f090c2005ffff or 0x816f090c2005ffff Severity Info Serviceable No Automatically notify support No Alert C...

Страница 940: ...formation Prefix PLAT ID 0143 User Response No action information only 816f090c 2007ffff PhysicalMemoryElementName on Subsystem MemoryElementName is no longer Throttled DIMM 7 This message is for the use case when an implementation has detected Memory is no longer Throttled May also be shown as 816f090c2007ffff or 0x816f090c2007ffff Severity Info Serviceable No Automatically notify support No Aler...

Страница 941: ...mation Prefix PLAT ID 0143 User Response No action information only 816f090c 2009ffff PhysicalMemoryElementName on Subsystem MemoryElementName is no longer Throttled DIMM 9 This message is for the use case when an implementation has detected Memory is no longer Throttled May also be shown as 816f090c2009ffff or 0x816f090c2009ffff Severity Info Serviceable No Automatically notify support No Alert C...

Страница 942: ...formation Prefix PLAT ID 0143 User Response No action information only 816f090c 200bffff PhysicalMemoryElementName on Subsystem MemoryElementName is no longer Throttled DIMM 11 This message is for the use case when an implementation has detected Memory is no longer Throttled May also be shown as 816f090c200bffff or 0x816f090c200bffff Severity Info Serviceable No Automatically notify support No Ale...

Страница 943: ...mation Prefix PLAT ID 0143 User Response No action information only 816f090c 200dffff PhysicalMemoryElementName on Subsystem MemoryElementName is no longer Throttled DIMM 13 This message is for the use case when an implementation has detected Memory is no longer Throttled May also be shown as 816f090c200dffff or 0x816f090c200dffff Severity Info Serviceable No Automatically notify support No Alert ...

Страница 944: ...formation Prefix PLAT ID 0143 User Response No action information only 816f090c 200fffff PhysicalMemoryElementName on Subsystem MemoryElementName is no longer Throttled DIMM 15 This message is for the use case when an implementation has detected Memory is no longer Throttled May also be shown as 816f090c200fffff or 0x816f090c200fffff Severity Info Serviceable No Automatically notify support No Ale...

Страница 945: ...mation Prefix PLAT ID 0143 User Response No action information only 816f090c 2011ffff PhysicalMemoryElementName on Subsystem MemoryElementName is no longer Throttled DIMM 17 This message is for the use case when an implementation has detected Memory is no longer Throttled May also be shown as 816f090c2011ffff or 0x816f090c2011ffff Severity Info Serviceable No Automatically notify support No Alert ...

Страница 946: ...formation Prefix PLAT ID 0143 User Response No action information only 816f090c 2013ffff PhysicalMemoryElementName on Subsystem MemoryElementName is no longer Throttled DIMM 19 This message is for the use case when an implementation has detected Memory is no longer Throttled May also be shown as 816f090c2013ffff or 0x816f090c2013ffff Severity Info Serviceable No Automatically notify support No Ale...

Страница 947: ...mation Prefix PLAT ID 0143 User Response No action information only 816f090c 2015ffff PhysicalMemoryElementName on Subsystem MemoryElementName is no longer Throttled DIMM 21 This message is for the use case when an implementation has detected Memory is no longer Throttled May also be shown as 816f090c2015ffff or 0x816f090c2015ffff Severity Info Serviceable No Automatically notify support No Alert ...

Страница 948: ...formation Prefix PLAT ID 0143 User Response No action information only 816f090c 2017ffff PhysicalMemoryElementName on Subsystem MemoryElementName is no longer Throttled DIMM 23 This message is for the use case when an implementation has detected Memory is no longer Throttled May also be shown as 816f090c2017ffff or 0x816f090c2017ffff Severity Info Serviceable No Automatically notify support No Ale...

Страница 949: ...ix PLAT ID 0143 User Response No action information only 816f0a07 0301ffff The Processor ProcessorElementName is no longer operating in a Degraded State CPU 1 This message is for the use case when an implementation has detected a Processor is no longer running in the Degraded state May also be shown as 816f0a070301ffff or 0x816f0a070301ffff Severity Info Serviceable No Automatically notify support...

Страница 950: ...0039 User Response No action information only 816f0a0c 2001ffff An Over Temperature Condition has been removed on the PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 1 This message is for the use case when an implementation has detected an Over Temperature Condition for Memory that has been Removed May also be shown as 816f0a0c2001ffff or 0x816f0a0c2001ffff Severity Info Serviceable ...

Страница 951: ...mation Prefix PLAT ID 0147 User Response No action information only 816f0a0c 2003ffff An Over Temperature Condition has been removed on the PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 3 This message is for the use case when an implementation has detected an Over Temperature Condition for Memory that has been Removed May also be shown as 816f0a0c2003ffff or 0x816f0a0c2003ffff Seve...

Страница 952: ...formation Prefix PLAT ID 0147 User Response No action information only 816f0a0c 2005ffff An Over Temperature Condition has been removed on the PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 5 This message is for the use case when an implementation has detected an Over Temperature Condition for Memory that has been Removed May also be shown as 816f0a0c2005ffff or 0x816f0a0c2005ffff S...

Страница 953: ...mation Prefix PLAT ID 0147 User Response No action information only 816f0a0c 2007ffff An Over Temperature Condition has been removed on the PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 7 This message is for the use case when an implementation has detected an Over Temperature Condition for Memory that has been Removed May also be shown as 816f0a0c2007ffff or 0x816f0a0c2007ffff Seve...

Страница 954: ...formation Prefix PLAT ID 0147 User Response No action information only 816f0a0c 2009ffff An Over Temperature Condition has been removed on the PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 9 This message is for the use case when an implementation has detected an Over Temperature Condition for Memory that has been Removed May also be shown as 816f0a0c2009ffff or 0x816f0a0c2009ffff S...

Страница 955: ...mation Prefix PLAT ID 0147 User Response No action information only 816f0a0c 200bffff An Over Temperature Condition has been removed on the PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 11 This message is for the use case when an implementation has detected an Over Temperature Condition for Memory that has been Removed May also be shown as 816f0a0c200bffff or 0x816f0a0c200bffff Sev...

Страница 956: ...formation Prefix PLAT ID 0147 User Response No action information only 816f0a0c 200dffff An Over Temperature Condition has been removed on the PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 13 This message is for the use case when an implementation has detected an Over Temperature Condition for Memory that has been Removed May also be shown as 816f0a0c200dffff or 0x816f0a0c200dffff ...

Страница 957: ...mation Prefix PLAT ID 0147 User Response No action information only 816f0a0c 200fffff An Over Temperature Condition has been removed on the PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 15 This message is for the use case when an implementation has detected an Over Temperature Condition for Memory that has been Removed May also be shown as 816f0a0c200fffff or 0x816f0a0c200fffff Sev...

Страница 958: ...formation Prefix PLAT ID 0147 User Response No action information only 816f0a0c 2011ffff An Over Temperature Condition has been removed on the PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 17 This message is for the use case when an implementation has detected an Over Temperature Condition for Memory that has been Removed May also be shown as 816f0a0c2011ffff or 0x816f0a0c2011ffff ...

Страница 959: ...mation Prefix PLAT ID 0147 User Response No action information only 816f0a0c 2013ffff An Over Temperature Condition has been removed on the PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 19 This message is for the use case when an implementation has detected an Over Temperature Condition for Memory that has been Removed May also be shown as 816f0a0c2013ffff or 0x816f0a0c2013ffff Sev...

Страница 960: ...formation Prefix PLAT ID 0147 User Response No action information only 816f0a0c 2015ffff An Over Temperature Condition has been removed on the PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 21 This message is for the use case when an implementation has detected an Over Temperature Condition for Memory that has been Removed May also be shown as 816f0a0c2015ffff or 0x816f0a0c2015ffff ...

Страница 961: ...mation Prefix PLAT ID 0147 User Response No action information only 816f0a0c 2017ffff An Over Temperature Condition has been removed on the PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 23 This message is for the use case when an implementation has detected an Over Temperature Condition for Memory that has been Removed May also be shown as 816f0a0c2017ffff or 0x816f0a0c2017ffff Sev...

Страница 962: ...ritical Temperature SNMP Trap ID 0 CIM Information Prefix PLAT ID 0147 User Response No action information only 816f0a13 0301ffff System ComputerSystemElementName has recovered from a Fatal Bus Error CPU 1 PECI This message is for the use case when an implementation has detected that a system has recovered from a Bus Fatal Error May also be shown as 816f0a130301ffff or 0x816f0a130301ffff Severity ...

Страница 963: ...tion has detected that a system has recovered from a Bus Fatal Error May also be shown as 816f0a130302ffff or 0x816f0a130302ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Other SNMP Trap ID 50 CIM Information Prefix PLAT ID 0245 User Response 1 Trained technician only Replace microprocessor n see Removing a microprocessor and heat sink and Replacing a mic...

Страница 964: ...952 Lenovo System x3650 M4 HD Installation and Service Guide ...

Страница 965: ... a change of states that is normal behavior Warning A warning is not as severe as an error but if possible the condition should be corrected before it becomes an error It might also be a condition that requires additional monitoring or maintenance Error An error typically indicates a failure or critical condition that impairs service or an expected function User response The actions that you shoul...

Страница 966: ... matching Processors are installed in the correct Processor sockets according to the service information for this product 2 Check IBM support site for an applicable service bulletin that applies to this Processor error 3 Trained Service technician only Replace Processor Inspect Processor socket and replace the system board first if socket is damaged I 18006 I 18006 A mismatch between the maximum a...

Страница 967: ...is product Add link to Memory chart Correct any configuration issues found 2 Trained Service technician only Replace associated Processor Inspect Processor socket and replace the system board first if socket is damaged I 18009 I 18009 A core speed mismatch has been detected for one or more processor packages Explanation Processors have mismatched Core Speed Severity Error User Response Complete th...

Страница 968: ...rs are installed in the correct processor sockets according to the service information for this product Correct any mismatch found 2 Check IBM support site for an applicable service bulletin or firmware update that applies to this Processor error 3 Trained Service technician only Replace the system board I 1800C I 1800C A cache type mismatch has been detected for one or more processor packages Exp...

Страница 969: ... support site for an applicable service bulletin or firmware update that applies to this Processor error 3 Trained Service technician only Replace the system board I 1800F I 1800F A processor family mismatch has been detected for one or more processor packages Explanation Processors have mismatched Family Severity Error User Response Complete the following steps 1 Verify that matching Processors a...

Страница 970: ...If slot not available or error re occurs replace adapter 4 Trained Service technician only If adapter was moved to a different slot and error did not re occur verify that this is not a system limitation and then replace the system board Also if this is not the initial installation and the error persists after adapter replacement replace system board I 2018003 I 2018003 A bad option ROM checksum wa...

Страница 971: ...18001 The firmware image capsule signature for the currently booted flash bank is invalid Explanation Current Bank CRTM Capsule Update Signature Invalid Severity Info User Response Complete the following steps 1 Reboot system Will come up on backup UEFI image Reflash the primary UEFI image 2 If error does not persist no additional recovery action is required 3 If error persists or boot is unsucces...

Страница 972: ...nly Replace the system board I 58015 I 58015 Memory spare copy initiated Explanation Spare Copy Started Severity Info User Response Complete the following steps 1 No user required for this event This is for informational purposes only I 580A4 I 580A4 Memory population change detected Explanation DIMM Population Change Detected Severity Info User Response Complete the following steps 1 Check system...

Страница 973: ...planation Uncorrectable processor error detected Severity Error User Response Complete the following steps 1 Check IBM support site for an applicable service bulletin or firmware update that applies to this error 2 Reboot system If problem persists escalate to the next level of supprt S 2011001 S 2011001 An Uncorrected PCIe Error has Occurred at Bus Device Function The Vendor ID for the device is ...

Страница 974: ...configuring slot to Gen1 or Gen2 may be required Gen1 Gen2 settings can be configured via F1 Setup System Settings Devices and I O Ports PCIe Gen1 Gen2 Gen3 Speed Selection or the ASU Utility 2 Check IBM support site for an applicable device driver firmware update version of service information for this product or other information that applies to this error Load new device driver and any required...

Страница 975: ...40007 A firmware fault has been detected in the UEFI image Explanation Internal UEFI Firmware Fault Detected System halted Severity Error User Response Complete the following steps 1 Check IBM support site for an applicable service bulletin or firmware update that applies to this error 2 Reflash UEFI image 3 Trained service technician only Replace the system board S 3050007 S 3050007 A firmware fa...

Страница 976: ...e that applies to this error 5 Reflash UEFI firmware 6 Remove and re install CMOS battery for 30 seconds to clear CMOS contents 7 Trained service technician only Replace the system board S 3060007 S 3060007 A firmware fault has been detected in the UEFI image Explanation Internal UEFI Firmware Fault Detected System halted Severity Error User Response Complete the following steps 1 Check IBM suppor...

Страница 977: ...cian only Replace the system board S 3818007 S 3818007 The firmware image capsules for both flash banks could not be verified Explanation CRTM image capsule could not be verified Severity Error User Response Complete the following steps 1 If system failed to boot successfully DC cycle system 2 If system boots to F1 steup flash UEFI image and reset bank to primary if required If system boots withou...

Страница 978: ...ce system board 6 Trained Service technician only Replace affected Processor 7 Trained Service technician only Replace system board S 51006 S 51006 A memory mismatch has been detected Please verify that the memory configuration is valid Explanation One or More Mismatched DIMMs Detected Severity Error User Response Complete the following steps 1 Could follow an uncorrectable memory error or failed ...

Страница 979: ...memory channel across channels one at a time to a different memory channel or Processor check service information for this product Install guide for population requirements for sparing paring modes If problem follows a moved DIMM to a different memory channel replace that DIMM 5 Check IBM support site for an applicable service bulletin or firmware update that applies to this memory error 6 Trained...

Страница 980: ...ned Service technician only 4 Trained Service Technician Only Replace the processor S 680B9 S 680B9 External QPI Link Failure Detected Explanation External QPI Link Failure Detected Severity Error User Response Complete the following steps 1 Check IBM support site for an applicable service bulletin or firmware update that applies to this error 2 Inspect processor socket for foreign debris or damag...

Страница 981: ... to UEFI Recovery section of service information for this product 3 Trained service technician only Replace the system board W 305000A W 305000A An invalid date and time have been detected Explanation RTC Date and Time Incorrect Severity Warning User Response Complete the following steps 1 Check IMM chassis event log This event should immediately precede 0068002 error Service that event or any oth...

Страница 982: ...equired Controller Explanation DRIVER HEALTH PROTOCOL Reports Reboot Required Controller Severity Warning User Response Complete the following steps 1 No action required system will reboot at the end of POST 2 If problem persists switch to backup UEFI or reflash current UEFI image 3 Trained Service Technician Only Replace system board W 305800C W 305800C DRIVER HEALTH PROTOCOL Reports System Shutd...

Страница 983: ...ned Service Technician Only Replace system board W 3808000 W 3808000 An IMM communication failure has occurred Explanation IMM Communication Failure Severity Warning User Response Complete the following steps 1 Remove AUX power from the node This will reboot the entire node 2 Check IBM support site for an applicable service bulletin or firmware update that applies to this error 3 Reflash UEFI Firm...

Страница 984: ...flash IMM Firmware 5 Remove and re install CMOS battery for 30 seconds to clear CMOS contents 6 Trained Service technician only Replace the system board W 3818005 W 3818005 The CRTM flash driver could not successfully flash the staging area The update was aborted Explanation CRTM Update Aborted Severity Warning User Response Complete the following steps 1 Continue booting system If system does not...

Страница 985: ...t memory channel If either of these conditions is found correct and retry with the same DIMM Note Event Log may contain a recent 00580A4 event denoting detected change in DIMM population that could be related to this problem 2 Check IBM support site for an applicable firmware update that applies to this memory error The release notes will list the known problems the update addresses 3 If the previ...

Страница 986: ...e populated according to the guidelines in the service information for this product W 580A1 W 580A1 Invalid memory configuration for Mirror Mode Please correct memory configuration Explanation Unsupported DIMM Population for Mirror Mode Severity Error User Response Complete the following steps 1 If a DIMM connector error LED is lit resolve the failure 2 Make sure that the DIMM connectors are corre...

Страница 987: ...as recently Installed Moved or Serviced makesure the batter is properly seated 2 Check IBM support site for an applicable service bulletin or firmware update that applies to this error 3 Replace CMOS Battery 4 Trained Service technician only Replace the system board Appendix B UEFI POST diagnostic codes 975 ...

Страница 988: ...976 Lenovo System x3650 M4 HD Installation and Service Guide ...

Страница 989: ... result when you run the DSA Broadcom network test 405 000 000 BRCM TestControlRegisters Test Passed The test passed Recoverable No Severity Event Serviceable No Automatically notify support No Related links IBM Support website Latest level of DSA Latest level of BMC IMM 405 001 000 BRCM TestMIIRegisters Test Passed The test passed Recoverable No Severity Event Serviceable No Automatically notify ...

Страница 990: ...05 003 000 BRCM TestInternalMemory Test Passed The test passed Recoverable No Severity Event Serviceable No Automatically notify support No Related links IBM Support website Latest level of DSA Latest level of BMC IMM 405 004 000 BRCM TestInterrupt Test Passed The test passed Recoverable No Severity Event Serviceable No Automatically notify support No 978 Lenovo System x3650 M4 HD Installation and...

Страница 991: ... No Related links IBM Support website Latest level of DSA Latest level of BMC IMM 405 006 000 BRCM TestLoopbackPhysical Test Passed The test passed Recoverable No Severity Event Serviceable No Automatically notify support No Related links IBM Support website Latest level of DSA Latest level of BMC IMM 405 007 000 BRCM TestLEDs Test Passed The test passed Recoverable No Appendix C DSA diagnostic te...

Страница 992: ...No Severity Warning Serviceable No Automatically notify support No Related links IBM Support website Latest level of DSA Latest level of BMC IMM 405 801 000 BRCM TestMIIRegisters Test Aborted The MII register test was canceled Recoverable No Severity Warning Serviceable No Automatically notify support No Related links IBM Support website Latest level of DSA Latest level of BMC IMM 980 Lenovo Syste...

Страница 993: ...3 000 BRCM TestInternalMemory Test Aborted The internal memory test was canceled Recoverable No Severity Warning Serviceable No Automatically notify support No Related links IBM Support website Latest level of DSA Latest level of BMC IMM 405 804 000 BRCM TestInterrupt Test Aborted The interrupt test was canceled Recoverable No Severity Warning Serviceable No Automatically notify support No Appendi...

Страница 994: ...port website Latest level of DSA Latest level of BMC IMM 405 806 000 BRCM TestLoopbackPhysical Test Aborted Loopback testing at the physical layer was canceled Recoverable No Severity Warning Serviceable No Automatically notify support No Related links IBM Support website Latest level of DSA Latest level of BMC IMM 405 807 000 BRCM TestLEDs Test Aborted Verification of status LEDs was canceled Rec...

Страница 995: ...nt firmware level and upgrade if necessary The installed firmware level can be found in the DSA Diagnostic Event Log within the Firmware VPD section for this component 2 Rerun the test 3 If failure remains refer to Troubleshooting by symptom in the system Installation and Service Guide for the next corrective action Related links IBM Support website Latest level of DSA Latest level of BMC IMM 405 ...

Страница 996: ... while testing non volatile RAM Recoverable No Severity Error Serviceable Yes Automatically notify support No User Response Complete the following steps 1 Check component firmware level and upgrade if necessary The installed firmware level can be found in the DSA Diagnostic Event Log within the Firmware VPD section for this component 2 Rerun the test 3 If failure remains refer to Troubleshooting b...

Страница 997: ...TestInterrupt Test Failed A failure was detected while testing interrupts Recoverable No Severity Error Serviceable Yes Automatically notify support No User Response Complete the following steps 1 Check component firmware level and upgrade if necessary The installed firmware level can be found in the DSA Diagnostic Event Log within the Firmware VPD section for this component 2 Rerun the test 3 If ...

Страница 998: ...of BMC IMM 405 906 000 BRCM TestLoopbackPhysical Test Failed A failure was detected during the loopback test at the physical layer Recoverable No Severity Error Serviceable Yes Automatically notify support No User Response Complete the following steps 1 Check component firmware level and upgrade if necessary The installed firmware level can be found in the DSA Diagnostic Event Log within the Firmw...

Страница 999: ...mponent 2 Rerun the test 3 If failure remains refer to Troubleshooting by symptom in the system Installation and Service Guide for the next corrective action Related links IBM Support website Latest level of DSA Latest level of BMC IMM DSA Brocade test results The following messages can result when you run the Brocade test Test results for the DSA Brocade test The following messages can result whe...

Страница 1000: ...ted links IBM Support website Latest level of DSA Latest level of BMC IMM 218 002 000 Brocade SerdesLoopbackTest Passed The test passed Recoverable No Severity Event Serviceable No Automatically notify support No Related links IBM Support website Latest level of DSA Latest level of BMC IMM 218 003 000 Brocade PCILoopbackTest Passed The test passed Recoverable No 988 Lenovo System x3650 M4 HD Insta...

Страница 1001: ...verable No Severity Event Serviceable No Automatically notify support No Related links IBM Support website Latest level of DSA Latest level of BMC IMM 218 005 000 Brocade SerdesEthLoopbackTest Passed The test passed Recoverable No Severity Event Serviceable No Automatically notify support No Related links IBM Support website Latest level of DSA Latest level of BMC IMM Appendix C DSA diagnostic tes...

Страница 1002: ... 800 000 Brocade MemoryTest Aborted The test was canceled Recoverable No Severity Warning Serviceable No Automatically notify support No Related links IBM Support website Latest level of DSA Latest level of BMC IMM 218 801 000 Brocade ExternalLoopbackTest Aborted The test was canceled Recoverable No Severity Warning Serviceable No Automatically notify support No 990 Lenovo System x3650 M4 HD Insta...

Страница 1003: ...lated links IBM Support website Latest level of DSA Latest level of BMC IMM 218 803 000 Brocade PCILoopbackTest Aborted The test was canceled Recoverable No Severity Warning Serviceable No Automatically notify support No Related links IBM Support website Latest level of DSA Latest level of BMC IMM 218 804 000 Brocade ExternalEthLoopbackTest Aborted The test was canceled Recoverable No Appendix C D...

Страница 1004: ...Severity Warning Serviceable No Automatically notify support No Related links IBM Support website Latest level of DSA Latest level of BMC IMM 218 806 000 Brocade InternalLoopbackTest Aborted The test was canceled Recoverable No Severity Warning Serviceable No Automatically notify support No Related links IBM Support website Latest level of DSA Latest level of BMC IMM 992 Lenovo System x3650 M4 HD ...

Страница 1005: ...port representative Related links IBM Support website Latest level of DSA Latest level of BMC IMM 218 901 000 Brocade ExternalLoopbackTest Failed A failure was detected during the Loopback test Recoverable No Severity Error Serviceable Yes Automatically notify support No User Response Complete the following steps 1 Check cable connections 2 Rerun the test 3 Verify whether the firmware is at proper...

Страница 1006: ...problem remains contact your IBM technical support representative Related links IBM Support website Latest level of DSA Latest level of BMC IMM 218 903 000 Brocade PCILoopbackTest Failed A failure was detected during the Loopback test Recoverable No Severity Error Serviceable Yes Automatically notify support No User Response Complete the following steps 1 Rerun the test 2 Verify whether the firmwa...

Страница 1007: ...P cable 2 Rerun the test 3 Verify whether the firmware is at proper level 4 Rerun the test 5 If the problem remains contact your IBM technical support representative Related links IBM Support website Latest level of DSA Latest level of BMC IMM 218 905 000 Brocade SerdesEthLoopbackTest Failed A failure was detected during the Loopback test Recoverable No Severity Error Serviceable Yes Automatically...

Страница 1008: ...he following steps 1 Rerun the test 2 Verify whether the firmware is at proper level 3 Rerun the test 4 If the problem remains contact your IBM technical support representative Related links IBM Support website Latest level of DSA Latest level of BMC IMM DSA checkpoint panel test results The following messages can result when you run the checkpoint panel test Test results for the DSA checkpoint pa...

Страница 1009: ... No User Response Complete the following steps 1 Inspect and reseat operator information panel cable at both ends 2 Verify that the Baseboard Management Controller BMC is working 3 Run the test again 4 If failure remains refer to Troubleshooting by symptom in the system Installation and Service Guide for the next corrective action Related links IBM Support website Latest level of DSA Latest level ...

Страница 1010: ...mptom in the system Installation and Service Guide for the next corrective action Related links IBM Support website Latest level of DSA Latest level of BMC IMM DSA CPU stress test results The following messages can result when you run the CPU stress test Test results for the DSA CPU stress test The following messages can result when you run the DSA CPU stress test 089 000 000 CPU Stress Test Passe...

Страница 1011: ...ction for this component The latest level firmware for this component can be found in reference to this system type at the IBM Support website 5 Run the test again 6 If the system has stopped responding turn off and restart the system and then run the test again 7 If failure remains refer to Troubleshooting by symptom in the system Installation and Service Guide for the next corrective action Rela...

Страница 1012: ...leshooting by symptom in the system Installation and Service Guide for the next corrective action Related links IBM Support website Latest level of DSA Latest level of BMC IMM 089 803 000 CPU Stress Test Aborted CPU Stress Test Aborted Memory size is insufficient to run the test At least 1GB is required Recoverable No Severity Warning Serviceable Yes Automatically notify support No Related links I...

Страница 1013: ...found in the DSA Diagnostic Event Log within the Firmware VPD section for this component 5 Run the test again 6 If the system has stopped responding turn off and restart the system and then run the test again 7 If failure remains refer to Troubleshooting by symptom in the system Installation and Service Guide for the next corrective action Related links IBM Support website Latest level of DSA Late...

Страница 1014: ...kTest Passed The test passed Recoverable No Severity Event Serviceable No Automatically notify support No Related links IBM Support website Latest level of DSA Latest level of BMC IMM 516 002 000 ELXUCNA ELXUCNA NIC LED Beacon Test Passed The test passed Recoverable No Severity Event Serviceable No Automatically notify support No Related links 1002 Lenovo System x3650 M4 HD Installation and Servic...

Страница 1015: ... Latest level of DSA Latest level of BMC IMM 516 801 000 ELXUCNA NIC PHY LoopBackTest Aborted Loopback testing at the physical layer was canceled Recoverable No Severity Warning Serviceable No Automatically notify support No Related links IBM Support website Latest level of DSA Latest level of BMC IMM 516 802 000 ELXUCNA ELXUCNA NIC LED Beacon Test Aborted Verification of status LEDs was canceled ...

Страница 1016: ...ary The installed firmware level can be found in the DSA Diagnostic Event Log within the Firmware VPD section for this component 2 Rerun the test 3 If failure remains refer to Troubleshooting by symptom in the system Installation and Service Guide for the next corrective action Related links IBM Support website Latest level of DSA Latest level of BMC IMM 516 901 000 ELXUCNA NIC PHY LoopBackTest Fa...

Страница 1017: ...ble No Severity Error Serviceable Yes Automatically notify support No User Response Complete the following steps 1 Check component firmware level and upgrade if necessary The installed firmware level can be found in the DSA Diagnostic Event Log within the Firmware VPD section for this component 2 Rerun the test 3 If failure remains refer to Troubleshooting by symptom in the system Installation and...

Страница 1018: ...fy support No User Response Complete the following steps 1 Remove power cables wait for 45 seconds reconnect and rerun the test 2 Make sure that the scalability cable connections are as per specification 3 Make sure that DSA and BIOS uEFI are at the latest level 4 If the problem remains contact your technical service representative Related links IBM Support website Latest level of DSA Latest level...

Страница 1019: ...st level of BMC IMM 401 901 001 EXA Port Ping Test Failed EXA Port Ping Test Failed Recoverable No Severity Error Serviceable Yes Automatically notify support No User Response Complete the following steps 1 Remove power cables wait for 45 seconds reconnect and rerun the test 2 Make sure that the scalability cable connections are as per specification 3 Check scalability cables for loose connections...

Страница 1020: ...rt No Related links IBM Support website Latest level of DSA Latest level of BMC IMM 217 800 000 HDD Test Aborted HDD Test Aborted The test was canceled Recoverable No Severity Warning Serviceable Yes Automatically notify support No User Response Complete the following steps 1 Check cable connections 2 Rerun the test 3 Verify that Hard drive supports self test and self test logging 4 If the problem...

Страница 1021: ...e is at the latest level 4 Rerun the test 5 If the problem remains contact your technical support representative Related links IBM Support website Latest level of DSA Latest level of BMC IMM DSA Intel network test results The following messages can result when you run the Intel network test Test results for the DSA Intel network test The following messages can result when you run the DSA Intel net...

Страница 1022: ...No Automatically notify support No Related links IBM Support website Latest level of DSA Latest level of BMC IMM 406 002 000 IANet FIFO Test Passed The test passed Recoverable No Severity Event Serviceable No Automatically notify support No Related links IBM Support website Latest level of DSA Latest level of BMC IMM 406 003 000 IANet Interrupts Test Passed 1010 Lenovo System x3650 M4 HD Installat...

Страница 1023: ...pback Test Passed The test passed Recoverable No Severity Event Serviceable No Automatically notify support No Related links IBM Support website Latest level of DSA Latest level of BMC IMM 406 800 000 IANet Registers Test Aborted Registers test was canceled Recoverable No Severity Warning Serviceable No Automatically notify support No Related links Appendix C DSA diagnostic test results 1011 ...

Страница 1024: ...t website Latest level of DSA Latest level of BMC IMM 406 802 000 IANet FIFO Test Aborted FIFO test was canceled Recoverable No Severity Warning Serviceable No Automatically notify support No Related links IBM Support website Latest level of DSA Latest level of BMC IMM 406 803 000 IANet Interrupts Test Aborted Interrupt test was canceled Recoverable No Severity Warning 1012 Lenovo System x3650 M4 ...

Страница 1025: ...Registers Test Failed A failure was detected during the Registers test Recoverable No Severity Error Serviceable Yes Automatically notify support No User Response Complete the following steps 1 Check component firmware level and upgrade if necessary The installed firmware level can be found in the DSA Diagnostic Event Log within the Firmware VPD section for this component 2 Rerun the test 3 If fai...

Страница 1026: ...erun the test 3 If failure remains refer to Troubleshooting by symptom in the system Installation and Service Guide for the next corrective action Related links IBM Support website Latest level of DSA Latest level of BMC IMM 406 902 000 IANet FIFO Test Failed A failure was detected during the FIFO test Recoverable No Severity Error Serviceable Yes Automatically notify support No User Response Comp...

Страница 1027: ...und in the DSA Diagnostic Event Log within the Firmware VPD section for this component 2 Rerun the test 3 Check interrupt assignments in the PCI Hardware section of the DSA Diagnostic Log If the ethernet device is sharing interrupts if possible modify the interrupt assignments using F1 Setup to assign a unique interrupt to the device 4 Rerun the test 5 If failure remains refer to Troubleshooting b...

Страница 1028: ... the next corrective action Related links IBM Support website Latest level of DSA Latest level of BMC IMM DSA LSI hard drive test results The following messages can result when you run the LSI hard drive test Test results for the DSA LSI hard drive test The following messages can result when you run the DSA LSI hard drive test 407 000 000 LSIESG DiskDefaultDiagnostic Test Passed The test passed Re...

Страница 1029: ...Serviceable Yes Automatically notify support No User Response Complete the following steps 1 Check cable connections 2 Rerun the test 3 Verify whether the firmware is at the latest level 4 Rerun the test 5 If the problem remains contact your IBM technical support representative Related links IBM Support website Latest level of DSA Latest level of BMC IMM DSA Mellanox adapter test results The follo...

Страница 1030: ... links IBM Support website Latest level of DSA Latest level of BMC IMM 408 001 000 MLNX MLNX_DiagnosticTestIBPort Test Passed Port Test Passed Recoverable No Severity Event Serviceable No Automatically notify support No Related links IBM Support website Latest level of DSA Latest level of BMC IMM 408 800 000 MLNX MLNX_DiagnosticTestEthernetPort Test Aborted Port Test was canceled Recoverable No Se...

Страница 1031: ...SA Latest level of BMC IMM 408 900 000 MLNX MLNX_DiagnosticTestEthernetPort Test Failed Port Test Failed Recoverable No Severity Error Serviceable Yes Automatically notify support No User Response Complete the following steps 1 Make sure that the physical link of the port under test in the active state 2 If these condition was met but the test keeps failing the port s adapter might be faulty 3 Try...

Страница 1032: ... met but the test keeps failing the port s adapter might be faulty 3 Try replacing the adapter and repeating the test Related links IBM Support website Latest level of DSA Latest level of BMC IMM DSA memory isolation test results The following messages can result when you run the memory isolation test Test results for the DSA memory isolation test The following messages can result when you run the...

Страница 1033: ...otify support No Related links IBM Support website Latest level of DSA Latest level of BMC IMM 201 000 002 Standalone Memory Test Passed Quick Full Memory Test CPU 2 Passed Recoverable No Severity Event Serviceable No Automatically notify support No Related links IBM Support website Latest level of DSA Latest level of BMC IMM 201 000 003 Standalone Memory Test Passed Quick Full Memory Test CPU 3 P...

Страница 1034: ...Serviceable No Automatically notify support No Related links IBM Support website Latest level of DSA Latest level of BMC IMM 201 811 000 Standalone Memory Test Aborted Unable to Locate SMBIOS key _SM_ Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each act...

Страница 1035: ... notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and disconnect it from power Wait for 45 seconds Reseat DIMM s Reconnect it to power 4 Make sure that DSA and BIOS uEFI are at the latest level Related links IBM Su...

Страница 1036: ...BIOS key _SM_ Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and disconnect it from power Wait for 45 seconds Reseat DIMM s Reconnect it to power 4 Mak...

Страница 1037: ...e Memory Test Aborted Memory test is not supported for this system Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and disconnect it from power Wait for...

Страница 1038: ...A Latest level of BMC IMM 201 812 003 Standalone Memory Test Aborted Memory test is not supported for this system Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off t...

Страница 1039: ...BIOS uEFI are at the latest level Related links IBM Support website Latest level of DSA Latest level of BMC IMM 201 813 001 Standalone Memory Test Aborted Chipset Error Can not turn OFF ECC error reporting in CPU Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test af...

Страница 1040: ...em and disconnect it from power Wait for 45 seconds Reseat DIMM s Reconnect it to power 4 Make sure that DSA and BIOS uEFI are at the latest level Related links IBM Support website Latest level of DSA Latest level of BMC IMM 201 813 003 Standalone Memory Test Aborted Chipset Error Can not turn OFF ECC error reporting in CPU Recoverable No Severity Warning Serviceable No Automatically notify suppor...

Страница 1041: ...lete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and disconnect it from power Wait for 45 seconds Reseat DIMM s Reconnect it to power 4 Make sure that DSA and BIOS uEFI are at the latest level Related links IBM Support website Latest level of DSA Lat...

Страница 1042: ...eature for CPU Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and disconnect it from power Wait for 45 seconds Reseat DIMM s Reconnect it to power 4 Ma...

Страница 1043: ... Aborted Program Error with Quick Memory Menu Option Selection Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and disconnect it from power Wait for 45 ...

Страница 1044: ...test level of BMC IMM 201 815 002 Standalone Memory Test Aborted Program Error with Quick Memory Menu Option Selection Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn ...

Страница 1045: ...BIOS uEFI are at the latest level Related links IBM Support website Latest level of DSA Latest level of BMC IMM 201 816 000 Standalone Memory Test Aborted Program Error with Full Memory Menu Option Selection Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after e...

Страница 1046: ...em and disconnect it from power Wait for 45 seconds Reseat DIMM s Reconnect it to power 4 Make sure that DSA and BIOS uEFI are at the latest level Related links IBM Support website Latest level of DSA Latest level of BMC IMM 201 816 002 Standalone Memory Test Aborted Program Error with Full Memory Menu Option Selection Recoverable No Severity Warning Serviceable No Automatically notify support No ...

Страница 1047: ...ponse Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and disconnect it from power Wait for 45 seconds Reseat DIMM s Reconnect it to power 4 Make sure that DSA and BIOS uEFI are at the latest level Related links IBM Support website Latest level ...

Страница 1048: ...MBIOS key _SM_ Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and disconnect it from power Wait for 45 seconds Reseat DIMM s Reconnect it to power 4 Ma...

Страница 1049: ... Test Aborted Unable to Locate SMBIOS key _SM_ Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and disconnect it from power Wait for 45 seconds Reseat D...

Страница 1050: ...evel of BMC IMM 201 819 001 Standalone Memory Test Aborted The start end address ranges in the restricted area of the memory Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3...

Страница 1051: ...BIOS uEFI are at the latest level Related links IBM Support website Latest level of DSA Latest level of BMC IMM 201 819 003 Standalone Memory Test Aborted The start end address ranges in the restricted area of the memory Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the...

Страница 1052: ...em and disconnect it from power Wait for 45 seconds Reseat DIMM s Reconnect it to power 4 Make sure that DSA and BIOS uEFI are at the latest level Related links IBM Support website Latest level of DSA Latest level of BMC IMM 201 820 001 Standalone Memory Test Aborted Memory Upper limit is less than 16 Mbytes Recoverable No Severity Warning Serviceable No Automatically notify support No User Respon...

Страница 1053: ...lete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and disconnect it from power Wait for 45 seconds Reseat DIMM s Reconnect it to power 4 Make sure that DSA and BIOS uEFI are at the latest level Related links IBM Support website Latest level of DSA Lat...

Страница 1054: ...MTRR registers Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and disconnect it from power Wait for 45 seconds Reseat DIMM s Reconnect it to power 4 Ma...

Страница 1055: ...ange MTRR registers are larger than fixed range MTRR registers Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and disconnect it from power Wait for 45 ...

Страница 1056: ...el of DSA Latest level of BMC IMM 201 822 000 Standalone Memory Test Aborted Invalid MTRR service request Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the syste...

Страница 1057: ...BIOS uEFI are at the latest level Related links IBM Support website Latest level of DSA Latest level of BMC IMM 201 822 002 Standalone Memory Test Aborted Invalid MTRR service request Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the prob...

Страница 1058: ... 45 seconds Reseat DIMM s Reconnect it to power 4 Make sure that DSA and BIOS uEFI are at the latest level Related links IBM Support website Latest level of DSA Latest level of BMC IMM 201 824 000 Standalone Memory Test Aborted Node Interleave feature must be OFF Go to Setup and disable Node Interleave option and then re run the test Recoverable No Severity Warning Serviceable No Automatically not...

Страница 1059: ...plete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and disconnect it from power Wait for 45 seconds Reseat DIMM s Reconnect it to power 4 Make sure that DSA and BIOS uEFI are at the latest level Related links IBM Support website Latest level of DSA La...

Страница 1060: ...leave option and then re run the test Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and disconnect it from power Wait for 45 seconds Reseat DIMM s Rec...

Страница 1061: ...Standalone Memory Test Aborted BIOS Memory Controller has been disabled Go to Setup and Enable Memory Controller Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off th...

Страница 1062: ... Support website Latest level of DSA Latest level of BMC IMM 201 826 003 Standalone Memory Test Aborted BIOS Memory Controller has been disabled Go to Setup and Enable Memory Controller Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the pr...

Страница 1063: ... sure that DSA and BIOS uEFI are at the latest level Related links IBM Support website Latest level of DSA Latest level of BMC IMM 201 827 001 Standalone Memory Test Aborted BIOS ECC function has been disabled by BIOS Go to Setup and enable ECC generation Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions ...

Страница 1064: ...e system and disconnect it from power Wait for 45 seconds Reseat DIMM s Reconnect it to power 4 Make sure that DSA and BIOS uEFI are at the latest level Related links IBM Support website Latest level of DSA Latest level of BMC IMM 201 827 003 Standalone Memory Test Aborted BIOS ECC function has been disabled by BIOS Go to Setup and enable ECC generation Recoverable No Severity Warning Serviceable ...

Страница 1065: ...lete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and disconnect it from power Wait for 45 seconds Reseat DIMM s Reconnect it to power 4 Make sure that DSA and BIOS uEFI are at the latest level Related links IBM Support website Latest level of DSA Lat...

Страница 1066: ...MASK registers Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and disconnect it from power Wait for 45 seconds Reseat DIMM s Reconnect it to power 4 Ma...

Страница 1067: ...set Error Problem clearing MSR machine check control registers Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and disconnect it from power Wait for 45 ...

Страница 1068: ...vel of BMC IMM 201 845 002 Standalone Memory Test Aborted Chipset Error Problem clearing MSR machine check control registers Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3...

Страница 1069: ...ake sure that DSA and BIOS uEFI are at the latest level Related links IBM Support website Latest level of DSA Latest level of BMC IMM 201 859 000 Standalone Memory Test Aborted INVALID XSECSRAT type Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each actio...

Страница 1070: ...em and disconnect it from power Wait for 45 seconds Reseat DIMM s Reconnect it to power 4 Make sure that DSA and BIOS uEFI are at the latest level Related links IBM Support website Latest level of DSA Latest level of BMC IMM 201 859 002 Standalone Memory Test Aborted INVALID XSECSRAT type Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the foll...

Страница 1071: ...lete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and disconnect it from power Wait for 45 seconds Reseat DIMM s Reconnect it to power 4 Make sure that DSA and BIOS uEFI are at the latest level Related links IBM Support website Latest level of DSA Lat...

Страница 1072: ...0 type 1 found Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and disconnect it from power Wait for 45 seconds Reseat DIMM s Reconnect it to power 4 Ma...

Страница 1073: ...01 860 003 Standalone Memory Test Aborted No OEM0 type 1 found Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and disconnect it from power Wait for 45 ...

Страница 1074: ... level of DSA Latest level of BMC IMM 201 861 001 Standalone Memory Test Aborted No SRAT type 1 found Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system an...

Страница 1075: ...BIOS uEFI are at the latest level Related links IBM Support website Latest level of DSA Latest level of BMC IMM 201 861 003 Standalone Memory Test Aborted No SRAT type 1 found Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem rema...

Страница 1076: ...em and disconnect it from power Wait for 45 seconds Reseat DIMM s Reconnect it to power 4 Make sure that DSA and BIOS uEFI are at the latest level Related links IBM Support website Latest level of DSA Latest level of BMC IMM 201 862 001 Standalone Memory Test Aborted No OEM1 structure found Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the fo...

Страница 1077: ...lete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and disconnect it from power Wait for 45 seconds Reseat DIMM s Reconnect it to power 4 Make sure that DSA and BIOS uEFI are at the latest level Related links IBM Support website Latest level of DSA Lat...

Страница 1078: ...OEM1 structure Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and disconnect it from power Wait for 45 seconds Reseat DIMM s Reconnect it to power 4 Ma...

Страница 1079: ...andalone Memory Test Aborted No IBMERROR key in OEM1 structure Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and disconnect it from power Wait for 45 ...

Страница 1080: ...level of DSA Latest level of BMC IMM 201 864 000 Standalone Memory Test Aborted No GAS located in OEM1 Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system a...

Страница 1081: ...BIOS uEFI are at the latest level Related links IBM Support website Latest level of DSA Latest level of BMC IMM 201 864 002 Standalone Memory Test Aborted No GAS located in OEM1 Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem re...

Страница 1082: ... disconnect it from power Wait for 45 seconds Reseat DIMM s Reconnect it to power 4 Make sure that DSA and BIOS uEFI are at the latest level Related links IBM Support website Latest level of DSA Latest level of BMC IMM 201 865 000 Standalone Memory Test Aborted No XSECSRAT key in OEM0 structure Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete th...

Страница 1083: ...lete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and disconnect it from power Wait for 45 seconds Reseat DIMM s Reconnect it to power 4 Make sure that DSA and BIOS uEFI are at the latest level Related links IBM Support website Latest level of DSA Lat...

Страница 1084: ...ture Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and disconnect it from power Wait for 45 seconds Reseat DIMM s Reconnect it to power 4 Make sure th...

Страница 1085: ...t Aborted EFI SAL Invalid parameter from GetMemoryMap function Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and disconnect it from power Wait for 45 ...

Страница 1086: ...test level of BMC IMM 201 866 003 Standalone Memory Test Aborted EFI SAL Invalid parameter from GetMemoryMap function Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn o...

Страница 1087: ...BIOS uEFI are at the latest level Related links IBM Support website Latest level of DSA Latest level of BMC IMM 201 867 001 Standalone Memory Test Aborted EFI SAL Buffer not allocated Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the prob...

Страница 1088: ...em and disconnect it from power Wait for 45 seconds Reseat DIMM s Reconnect it to power 4 Make sure that DSA and BIOS uEFI are at the latest level Related links IBM Support website Latest level of DSA Latest level of BMC IMM 201 867 003 Standalone Memory Test Aborted EFI SAL Buffer not allocated Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete t...

Страница 1089: ...lete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and disconnect it from power Wait for 45 seconds Reseat DIMM s Reconnect it to power 4 Make sure that DSA and BIOS uEFI are at the latest level Related links IBM Support website Latest level of DSA Lat...

Страница 1090: ...yMap too small Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and disconnect it from power Wait for 45 seconds Reseat DIMM s Reconnect it to power 4 Ma...

Страница 1091: ...t Aborted EFI SAL Invalid parameter from GetMemoryMap function Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and disconnect it from power Wait for 45 ...

Страница 1092: ...test level of BMC IMM 201 869 002 Standalone Memory Test Aborted EFI SAL Invalid parameter from GetMemoryMap function Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn o...

Страница 1093: ...hat DSA and BIOS uEFI are at the latest level Related links IBM Support website Latest level of DSA Latest level of BMC IMM 201 870 000 Standalone Memory Test Aborted CPU Doamin in ACPI not valid Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2...

Страница 1094: ...em and disconnect it from power Wait for 45 seconds Reseat DIMM s Reconnect it to power 4 Make sure that DSA and BIOS uEFI are at the latest level Related links IBM Support website Latest level of DSA Latest level of BMC IMM 201 870 002 Standalone Memory Test Aborted CPU Doamin in ACPI not valid Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete t...

Страница 1095: ...lete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and disconnect it from power Wait for 45 seconds Reseat DIMM s Reconnect it to power 4 Make sure that DSA and BIOS uEFI are at the latest level Related links IBM Support website Latest level of DSA Lat...

Страница 1096: ...re encountered Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and disconnect it from power Wait for 45 seconds Reseat DIMM s Reconnect it to power 4 Ma...

Страница 1097: ...t Aborted Data Mis compare encountered Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and disconnect it from power Wait for 45 seconds Reseat DIMM s Re...

Страница 1098: ...f BMC IMM 201 877 001 Standalone Memory Test Aborted BIOS Sparing in Extended PCI reg must be OFF Go to setup and disable sparing Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representat...

Страница 1099: ...BIOS uEFI are at the latest level Related links IBM Support website Latest level of DSA Latest level of BMC IMM 201 877 003 Standalone Memory Test Aborted BIOS Sparing in Extended PCI reg must be OFF Go to setup and disable sparing Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time ...

Страница 1100: ...em and disconnect it from power Wait for 45 seconds Reseat DIMM s Reconnect it to power 4 Make sure that DSA and BIOS uEFI are at the latest level Related links IBM Support website Latest level of DSA Latest level of BMC IMM 201 878 001 Standalone Memory Test Aborted Sparing feature must be turned OFF Go to setup and turn the sparing feature OFF Recoverable No Severity Warning Serviceable No Autom...

Страница 1101: ...lete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and disconnect it from power Wait for 45 seconds Reseat DIMM s Reconnect it to power 4 Make sure that DSA and BIOS uEFI are at the latest level Related links IBM Support website Latest level of DSA Lat...

Страница 1102: ... without cache Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and disconnect it from power Wait for 45 seconds Reseat DIMM s Reconnect it to power 4 Ma...

Страница 1103: ...RR register manipulation Can not write to memory without cache Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and disconnect it from power Wait for 45 ...

Страница 1104: ...DSA Latest level of BMC IMM 201 886 000 Standalone Memory Test Aborted Memory Upper limit is less than 16 Mbytes Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off th...

Страница 1105: ...BIOS uEFI are at the latest level Related links IBM Support website Latest level of DSA Latest level of BMC IMM 201 886 002 Standalone Memory Test Aborted Memory Upper limit is less than 16 Mbytes Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action ...

Страница 1106: ...t your technical service representative 3 Turn off the system and disconnect it from power Wait for 45 seconds Reseat DIMM s Reconnect it to power 4 Make sure that DSA and BIOS uEFI are at the latest level Related links IBM Support website Latest level of DSA Latest level of BMC IMM 201 899 000 Standalone Memory Test Aborted Memory Diagnostics Test Aborted by user Recoverable No Severity Warning S...

Страница 1107: ...01 899 002 Standalone Memory Test Aborted Memory Diagnostics Test Aborted by user Recoverable No Severity Warning Serviceable No Automatically notify support No Related links IBM Support website Latest level of DSA Latest level of BMC IMM 201 899 003 Standalone Memory Test Aborted Memory Diagnostics Test Aborted by user Recoverable No Severity Warning Serviceable No Automatically notify support No...

Страница 1108: ...r Wait for 45 seconds Reseat DIMM s Reconnect it to power 4 Make sure that DSA and BIOS uEFI are at the latest level 5 Replace any DIMMS s mentioned in error one by one 6 Make sure that all DIMMs are enabled in the Configuration Setup Utility program 7 If failure remains refer to Troubleshooting by symptom in the system Installation and Service Guide for the next corrective action Related links IB...

Страница 1109: ...IMM 201 901 002 Standalone Memory Test Failed Memory Diagnostics Test Failed Recoverable No Severity Error Serviceable Yes Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and disconnect it from power...

Страница 1110: ...t level 5 Replace any DIMMS s mentioned in error one by one 6 Make sure that all DIMMs are enabled in the Configuration Setup Utility program 7 If failure remains refer to Troubleshooting by symptom in the system Installation and Service Guide for the next corrective action Related links IBM Support website Latest level of DSA Latest level of BMC IMM DSA memory stress test results The following me...

Страница 1111: ...un the test again 4 If the system has stopped responding turn off and restart the system 5 Check the system firmware level and upgrade if necessary 6 Run the memory diagnostic to identify the specific failing DIMM 7 If the failure remains refer to Troubleshooting by symptom in the system Installation and Service Guide for the next corrective action Related links IBM Support website Latest level of...

Страница 1112: ...t level of BMC IMM 202 901 000 MemStr Test Failed Test Failed Recoverable No Severity Error Serviceable Yes Automatically notify support No User Response Complete the following steps 1 Execute the standard DSA memory diagnostics to validate all memory 2 Make sure that the DSA Diagnostic code is at the latest level 3 Turn off the system and disconnect it from power 4 Reseat the memory cards and DIM...

Страница 1113: ...ed by checking the Available System Memory in the Resource Utilization section of the DSA Diagnostic Event log 2 If necessary access the Configuration Setup Utility program by pressing F1 during system boot and enable all memory 3 Make sure that the DSA Diagnostic code is at the latest level 4 Run the test again 5 Execute the standard DSA memory diagnostics to validate all memory 6 If the failure ...

Страница 1114: ...bsite Latest level of DSA Latest level of BMC IMM 409 003 000 Nvidia DiagnosticServiceProvider Bandwidth Test Passed Nvidia GPU Bandwidth test passed Recoverable No Severity Event Serviceable No Automatically notify support No Related links IBM Support website Latest level of DSA Latest level of BMC IMM 409 004 000 Nvidia DiagnosticServiceProvider Query Test Passed Nvidia GPU Query test passed Rec...

Страница 1115: ...support No Related links IBM Support website Latest level of DSA Latest level of BMC IMM 409 006 000 Nvidia DiagnosticServiceProvider Binomial Test Passed Nvidia GPU Binomial test passed Recoverable No Severity Event Serviceable No Automatically notify support No Related links IBM Support website Latest level of DSA Latest level of BMC IMM 409 800 000 NVIDIA User Diagnostic Test Aborted NVIDIA Use...

Страница 1116: ...nceled Recoverable No Severity Warning Serviceable No Automatically notify support No Related links IBM Support website Latest level of DSA Latest level of BMC IMM 409 804 000 Nvidia DiagnosticServiceProvider Query Test Aborted Nvidia GPU Query test was canceled Recoverable No Severity Warning Serviceable No Automatically notify support No Related links IBM Support website Latest level of DSA 1104...

Страница 1117: ...A Latest level of BMC IMM 409 806 000 Nvidia DiagnosticServiceProvider Binomial Test Aborted Nvidia GPU Binomial test was canceled Recoverable No Severity Warning Serviceable No Automatically notify support No Related links IBM Support website Latest level of DSA Latest level of BMC IMM 409 900 000 NVIDIA User Diagnostic Test Failed NVIDIA User Diagnostic Test Failed Recoverable No Severity Event ...

Страница 1118: ...ceProvider Bandwidth Test Failed Nvidia GPU Bandwidth Test Failed Recoverable No Severity Error Serviceable Yes Automatically notify support No User Response Complete the following steps 1 Verify that the GPU is seated in the PCIe slot correctly by reseating the GPU Then power cycle the system 2 Verify that the power connectors to the GPU are connected firmly Then power cycle the system 3 Run nvid...

Страница 1119: ...ntative Related links IBM Support website Latest level of DSA Latest level of BMC IMM 409 905 000 Nvidia DiagnosticServiceProvider Matrix Test Failed Nvidia GPU Matrix Test Failed Recoverable No Severity Error Serviceable Yes Automatically notify support No User Response Complete the following steps 1 Verify that the GPU is seated in the PCIe slot correctly by reseating the GPU Then power cycle th...

Страница 1120: ...smi q In some cases this will report a poorly connected power cable 4 Rerun the diagnostics using the same GPU on system that is known to be working A variety of system issues can cause diagnostic failure 5 If the problem remains contact your IBM technical support representative Related links IBM Support website Latest level of DSA Latest level of BMC IMM DSA optical drive test results The followi...

Страница 1121: ...atest level 2 Run the test again 3 Check the drive cabling for loose or broken connections at both ends or damage to the cable Replace the cable if damage is present 4 Run the test again 5 Check system firmware level and upgrade if necessary The installed firmware level can be found in the DSA Diagnostic Event Log within the Firmware VPD section for this component 6 Run the test again Related link...

Страница 1122: ...the system Installation and Service Guide for the next corrective action Related links IBM Support website Latest level of DSA Latest level of BMC IMM 215 803 000 Optical Drive Test Failed Optical Drive Test Failed Disk may be in use by the operating system Recoverable No Severity Error Serviceable Yes Automatically notify support No User Response Complete the following steps 1 Wait for the system...

Страница 1123: ... Run the test again 5 If failure remains refer to Troubleshooting by symptom in the system Installation and Service Guide for the next corrective action Related links IBM Support website Latest level of DSA Latest level of BMC IMM 215 901 000 Optical Drive Test Aborted Optical Drive Test Aborted Drive media is not detected Recoverable No Severity Warning Serviceable Yes Automatically notify suppor...

Страница 1124: ... for 15 seconds for the media to be recognized Rerun the test 2 Check the drive cabling for loose or broken connections at both ends or damage to the cable Replace the cable if damage is present 3 Run the test again 4 If failure remains refer to Troubleshooting by symptom in the system Installation and Service Guide for the next corrective action Related links IBM Support website Latest level of D...

Страница 1125: ...re remains refer to Troubleshooting by symptom in the system Installation and Service Guide for the next corrective action Related links IBM Support website Latest level of DSA Latest level of BMC IMM DSA system management test results The following messages can result when you run the system management test Test results for the DSA system management test The following messages can result when you...

Страница 1126: ... Latest level of BMC IMM 166 802 001 IMM I2C Test Aborted Test cannot be completed for unknown reason Recoverable No Severity Warning Serviceable Yes Automatically notify support No User Response Perform the actions mentioned one at a time and try the test after each action 1 Turn off the system and disconnect it from power Wait for 45 seconds Reconnect it to power 2 Make sure that DSA and BMC IMM...

Страница 1127: ...evel of BMC IMM 166 804 001 IMM I2C Test Aborted Invalid Command Recoverable No Severity Warning Serviceable Yes Automatically notify support No User Response Perform the actions mentioned one at a time and try the test after each action 1 Turn off the system and disconnect it from power Wait for 45 seconds Reconnect it to power 2 Make sure that DSA and BMC IMM are at the latest level Related link...

Страница 1128: ...01 IMM I2C Test Aborted Timeout while processing command Recoverable No Severity Warning Serviceable Yes Automatically notify support No User Response Perform the actions mentioned one at a time and try the test after each action 1 Turn off the system and disconnect it from power Wait for 45 seconds Reconnect it to power 2 Make sure that DSA and BMC IMM are at the latest level Related links IBM Su...

Страница 1129: ...ted Reservation Canceled or Invalid Reservation ID Recoverable No Severity Warning Serviceable Yes Automatically notify support No User Response Perform the actions mentioned one at a time and try the test after each action 1 Turn off the system and disconnect it from power Wait for 45 seconds Reconnect it to power 2 Make sure that DSA and BMC IMM are at the latest level Related links IBM Support ...

Страница 1130: ...Recoverable No Severity Warning Serviceable Yes Automatically notify support No User Response Perform the actions mentioned one at a time and try the test after each action 1 Turn off the system and disconnect it from power Wait for 45 seconds Reconnect it to power 2 Make sure that DSA and BMC IMM are at the latest level Related links IBM Support website Latest level of DSA Latest level of BMC IMM...

Страница 1131: ...lly notify support No User Response Perform the actions mentioned one at a time and try the test after each action 1 Turn off the system and disconnect it from power Wait for 45 seconds Reconnect it to power 2 Make sure that DSA and BMC IMM are at the latest level Related links IBM Support website Latest level of DSA Latest level of BMC IMM 166 813 001 IMM I2C Test Aborted Cannot return number of ...

Страница 1132: ...n 1 Turn off the system and disconnect it from power Wait for 45 seconds Reconnect it to power 2 Make sure that DSA and BMC IMM are at the latest level Related links IBM Support website Latest level of DSA Latest level of BMC IMM 166 815 001 IMM I2C Test Aborted Invalid data field in Request Recoverable No Severity Warning Serviceable Yes Automatically notify support No User Response Perform the a...

Страница 1133: ...Reconnect it to power 2 Make sure that DSA and BMC IMM are at the latest level Related links IBM Support website Latest level of DSA Latest level of BMC IMM 166 817 001 IMM I2C Test Aborted Command response could not be provided Recoverable No Severity Warning Serviceable Yes Automatically notify support No User Response Perform the actions mentioned one at a time and try the test after each actio...

Страница 1134: ...t the latest level Related links IBM Support website Latest level of DSA Latest level of BMC IMM 166 819 001 IMM I2C Test Aborted Command response could not be provided SDR Repository in update mode Recoverable No Severity Warning Serviceable Yes Automatically notify support No User Response Perform the actions mentioned one at a time and try the test after each action 1 Turn off the system and di...

Страница 1135: ... latest level Related links IBM Support website Latest level of DSA Latest level of BMC IMM 166 821 001 IMM I2C Test Aborted Command response could not be provided BMC initialization in progress Recoverable No Severity Warning Serviceable Yes Automatically notify support No User Response Perform the actions mentioned one at a time and try the test after each action 1 Turn off the system and discon...

Страница 1136: ...st level of DSA Latest level of BMC IMM 166 823 001 IMM I2C Test Aborted Cannot execute command Insufficient privilege level Recoverable No Severity Warning Serviceable Yes Automatically notify support No User Response Perform the actions mentioned one at a time and try the test after each action 1 Turn off the system and disconnect it from power Wait for 45 seconds Reconnect it to power 2 Make su...

Страница 1137: ...est Failed IMM Indicates failure in RTMM bus BUS 0 Recoverable No Severity Error Serviceable Yes Automatically notify support No User Response Perform the actions mentioned one at a time and try the test after each action 1 Turn off the system and disconnect it from power Wait for 45 seconds Reconnect it to power 2 Make sure that DSA and BMC IMM are at the latest level 3 Run the test again 4 If fa...

Страница 1138: ...e next corrective action Related links IBM Support website Latest level of DSA Latest level of BMC IMM 166 905 001 IMM I2C Test Failed IMM Indicates failure in MAX7319 IO Expander bus BUS 4 Recoverable No Severity Error Serviceable Yes Automatically notify support No User Response Perform the actions mentioned one at a time and try the test after each action 1 Turn off the system and disconnect it...

Страница 1139: ...est again 4 If failure remains refer to Troubleshooting by symptom in the system Installation and Service Guide for the next corrective action Related links IBM Support website Latest level of DSA Latest level of BMC IMM 166 908 001 IMM I2C Test Failed IMM Indicates failure in PCA9557 IO Expander bus BUS 7 Recoverable No Severity Error Serviceable Yes Automatically notify support No User Response ...

Страница 1140: ...sults for the DSA tape drive test The following messages can result when you run the DSA tape drive test 264 000 000 Tape Test Passed Tape Test Passed Recoverable No Severity Event Serviceable No Automatically notify support No Related links IBM Support website Latest level of DSA Latest level of BMC IMM 264 901 000 Tape Test Failed An error was found in the tape alert log Recoverable No Severity ...

Страница 1141: ...2 000 Tape Test Failed Tape Test Failed Media is not detected Recoverable No Severity Error Serviceable Yes Automatically notify support No User Response Complete the following steps 1 Clean the tape drive using the appropriate cleaning media and install new media 2 Run the test again 3 Make sure that the drive firmware is at the latest level 4 Rerun the test after upgrading to the latest firmware...

Страница 1142: ...C IMM 264 904 000 Tape Test Failed Tape Test Failed Drive hardware error Recoverable No Severity Error Serviceable Yes Automatically notify support No User Response Complete the following steps 1 Check the tape drive cabling for loose or broken connections or damage to the cable Replace the cable if damage is present 2 Clean the tape drive using the appropriate cleaning media and install new media...

Страница 1143: ... Diagnostic Event Log within the Firmware VPD section for this component 3 Run the test again 4 If the system has stopped responding turn off and restart the system 5 Make sure that the drive firmware is at the latest level 6 Run the test again 7 If the failure remains refer to Troubleshooting by symptom in the system Installation and Service Guide for the next corrective action Related links IBM ...

Страница 1144: ...by symptom in the system Installation and Service Guide for the next corrective action Related links IBM Support website Latest level of DSA Latest level of BMC IMM 264 907 000 Tape Test Failed An error was found in the block address somewhere Recoverable No Severity Error Serviceable Yes Automatically notify support No User Response Complete the following steps 1 Clean the tape drive using the ap...

Страница 1145: ...se Complete the following steps 1 Make sure that medium is present 2 Clean the tape drive using the appropriate cleaning media and install new media Related links Support website Latest level of DSA Latest level of BMC IMM Appendix C DSA diagnostic test results 1133 ...

Страница 1146: ...1134 Lenovo System x3650 M4 HD Installation and Service Guide ...

Страница 1147: ...have installed new hardware or software in your environment check http www lenovo com serverproven to make sure that the hardware and software is supported by your product Go to http www lenovo com support to check for information to help you solve the problem Gather the following information to provide to the service technician This data will help the service technician quickly provide a solution...

Страница 1148: ... http www lenovo com support The most current version of the product documentation is available in the following product specific Information Centers Flex System products http pic dhe ibm com infocenter flexsys information index jsp System x products http shop lenovo com us en systems NeXtScale System products http pic dhe ibm com infocenter nxtscale documentation index jsp How to send DSA data Yo...

Страница 1149: ...anada call 1 800 IBM SERV 1 800 426 7378 Hardware service and support IBM is Lenovo s preferred service provider for the System x Flex System and NeXtScale System products You can receive hardware service through your Lenovo reseller or from IBM To locate a reseller authorized by Lenovo to provide warranty service go to http www ibm com partnerworld and click Business Partner Locator For IBM suppo...

Страница 1150: ...1138 Lenovo System x3650 M4 HD Installation and Service Guide ...

Страница 1151: ...ublication Lenovo may make improvements and or changes in the product s and or the program s described in this publication at any time without notice The products described in this document are not intended for use in implantation or other life support applications where malfunction may result in injury or death to persons The information contained in this document does not affect or change Lenovo...

Страница 1152: ...hard disk drive bays with the largest currently supported drives that are available from Lenovo Maximum memory might require replacement of the standard memory with an optional memory module Each solid state memory cell has an intrinsic finite number of write cycles that the cell can incur Therefore a solid state device has a maximum number of write cycles that it can be subjected to expressed as ...

Страница 1153: ...tered to 99 97 efficiency or greater using high efficiency particulate air HEPA filters that meet MIL STD 282 The deliquescent relative humidity of the particulate contamination must be more than 60 2 The room must be free of conductive contamination such as zinc whiskers Gaseous Copper Class G1 as per ANSI ISA 71 04 19853 Silver Corrosion rate of less than 300 Å in 30 days 1 ASHRAE 52 2 2008 Meth...

Страница 1154: ... required to take adequate measures European Union EMC Directive conformance statement This product is in conformity with the protection requirements of EU Council Directive 2014 30 EU on the approximation of the laws of the Member States relating to electromagnetic compatibility Lenovo cannot accept responsibility for any failure to satisfy the protection requirements resulting from a non recomme...

Страница 1155: ...n EMVG das EG Konformitätszeichen CE zu führen Verantwortlich für die Konformitätserklärung nach Paragraf 5 des EMVG ist die Lenovo Deutschland GmbH Meitnerstr 9 D 70563 Stuttgart Informationen in Hinsicht EMVG Paragraf 4 Abs 1 4 Das Gerät erfüllt die Schutzanforderungen nach EN 55024 und EN 55022 Klasse A Nach der EN 55022 Dies ist eine Einrichtung der Klasse A Diese Einrichtung kann im Wohnberei...

Страница 1156: ...cs guideline Japanese Statement of Compliance for Products More than 20A Korea Communications Commission KCC statement This is electromagnetic wave compatibility equipment for business Type A Sellers and users need to pay attention to it This is for any areas other than home Russia Electromagnetic Interference EMI Class A statement 1144 Lenovo System x3650 M4 HD Installation and Service Guide ...

Страница 1157: ...People s Republic of China Class A electronic emission statement Taiwan Class A compliance statement Appendix E Notices 1145 ...

Страница 1158: ...Taiwan BSMI RoHS declaration 1146 Lenovo System x3650 M4 HD Installation and Service Guide ...

Страница 1159: ...event log 135 assistance getting 1135 attention notices 5 Australia Class A statement 1142 automatic boot recovery ABR 164 availability server 15 B backplane cabling 182 backplane assembly 8x1 8 inch SSD removing 262 replacing 263 backup firmware starting 110 battery RAID adapter removing 201 replacing 203 battery system removing 266 replacing 269 bays 7 before you install a legacy operating syste...

Страница 1160: ...T UEFI 953 diagnostics program overview 137 diagnostics program DSA Preboot 12 DIMM installing 43 48 215 memory two DIMM per channel 2DPC 43 215 removing 214 replacing 220 two DIMM per channel 2DPC requirement 43 215 DIMM installation sequence 46 218 memory mirrored channel 46 218 rank sparing 48 219 display problems 146 documentation 4 CD 3 Documentation Browser 4 updates 1 using 1136 documentati...

Страница 1161: ...cing 203 front view 17 front view connectors 17 LED location 17 G gaseous contamination 1141 general problems 141 Germany Class A statement 1142 grease thermal 79 295 guidelines options installation 34 system reliability 35 H handling static sensitive devices 36 hard disk drive activity LED 17 problems 141 status LED 17 hardware requirements 3 hardware service and support telephone numbers 1137 ha...

Страница 1162: ...ntegrated functions 6 integrated management module overview 12 using 110 integrated management module II error messages 303 event log 135 136 programs 100 intermittent problems 143 internal connectors 28 introduction 1 IP address for the IMM 112 IPMI event log 135 136 IPMItool 136 J Japanese electromagnetic compatibility statements 1143 jumper UEFI boot recovery 162 jumpers system board 29 K Korea...

Страница 1163: ...tem board 108 PCI riser card assembly 222 PCI expansion slots 7 PCI riser slots installation configurations 228 supported configurations 228 PCI riser card LEDs location 134 PCI riser card assembly installing 95 removing 37 222 replacing 222 PCI riser card assembly full length stretching 39 PCI riser card assembly half length shrinking 40 People s Republic of China Class A electronic emission stat...

Страница 1164: ...ower supply 249 hot swap drive backplane 260 hot swap fan 241 hot swap hard disk drive 210 memory module 214 microprocessor 282 operator information panel 278 PCI riser card assembly 37 222 power paddle card 281 power paddle card cover 207 power supply 247 RAID adapter battery 201 RAID adapter flash power module 201 rear two hard disk drive kit 224 safety cover 206 ServeRAID adapter memory module ...

Страница 1165: ...D 99 using 102 ServerGuide CD 1 service and support before you call 1135 hardware 1137 software 1137 service bulletins 126 serviceability server 15 Setup utility 99 100 menu choices 104 starting 103 using 103 shrinking PCI riser card assembly 40 shutting down the server 23 slots PCI expansion 7 SMP 12 software requirements 3 software problems 157 software service and support telephone numbers 1137...

Страница 1166: ...19 firmware 99 Lenovo XClarity Administrator 115 server configuration 98 Systems Director 116 Systems Director IBM 116 Universal Unique Identifier UUID 117 USB connector 17 19 USB hypervisor flash device installing 69 removing 264 replacing 265 using embedded hypervisor 113 integrated management module 110 Setup utility 103 the remote presence feature 111 Utility program Advanced Settings 115 util...

Страница 1167: ......

Страница 1168: ......

Отзывы: