6600-NG User’s Manual
125-9110A
Page 8
SECTION 2 : CONTROLS & CONNECTIONS
2.1
MAIN UNIT, TOP PANEL
The model 6600-NG top panel provides easy access to all the connections. Please refer to Figure 2.1. (shown
on next page)
[1]
AC INPUT connector :
This is a 3-pin male circular connector. A power cord is provided with the 6600-NG. The circular connector
end of the power cord needs to be connected here. The power requirement of the 6600-NG is 90-260 VAC,
47-440 Hz with a maximum power consumption of 100 VA (200 VA with heaters). The pin-out of this
connector is provided in Appendix C
Caution:
Connecting incorrect power to the 6600-NG will cause considerable damage
[2]
AC Fuse :
A 5x20 mm fuse is located inside the fuse holder. This time-delay fuse, with a rating of 2.0 amps, 250 Volts
,
limits AC power to the unit.
[3]
AC On/Off switch :
This toggle switch connects (or disconnects) AC power between the AC INPUT connector and the 6600-NG.
Even when this switch is ON, the 6600-NG becomes fully operational only after the Power key located on the
keypad of the Remote Unit is pressed for a minimum of 3 seconds.
When an integrated battery is included, the battery-charging circuits inside the 6600-NG become active when
the AC On/Off switch is turned ON.
When internal heaters are included, the heater-control circuits inside the 6600-NG become active when the
AC On/Off switch is turned ON.
[4]
Battery Fuse :
This fuse is installed only if an integrated battery is included. A 5x20 mm fuse is located inside the fuse
holder. This time-delay fuse, with a rating of 10
amps, 250 Volts
,
limits Battery power to the unit.