6600-NG User’s Manual
125-9110A
Page 38
In this screen, the Upper section has a new symbol (with Up & Down arrows) to the left of the Pt Rate
Target value field. This indicates that the Pt Rate Target value can be jogged up or down repeatedly, in
steps of 1 knot/min, using the Arrow keys, until
CANC
is pressed. In this case, since the
Up-Arrow
key
was pressed, the Pt Rate Target value was incremented to 151.0 knots. Press
Up-Arrow
one more time
and the value will change to 152.0. Press
Down-Arrow
two times and the value decrements to 150.0.
Note: It is not possible to Jog a Rate Target value if it is blinking.
The incremental value for the Jog feature varies depending on Pt Rate units and is shown in the table
below.
Pt-Rate Units
Jog increment
knots/min
1.0
km/hr/sec
1.0
mph/min
1.0
inHg/min
0.01
mbar/min
0.1
psi/min
0.01
mmHg/min
0.1
kpa/min
0.01
Ps1 Rate Target value
The Ps1 Rate Target value can be changed only if the key# symbol
(7)
is displayed to the right of the Ps1
Rate Target value field. Press key ‘
7
’ on the keypad and the Lower section of the display will appear as
shown in Figure 3.19 below.
Figure 3.19 : Ps1 Rate Target value
Use the keypad to enter the desired value in the field shown. To clear an entry, press
CLR
. To accept the
entry, press
ENTER
. To exit this screen without changing the Rate Target value, press
CANC
. If the
number of digits entered (either before or after the decimal) exceeds the maximum allowed for the
current units, a long beep will be heard.
If the entered value exceeds the programmed limits, the following message will appear.
Ps1 Rate Target
Enter Ps1 Rate target value: feet/min
Use keys to jog target value
Press
CANC
to exit