6600-NG User’s Manual
125-9110A
Page 24
Ps2 units
Displayed
Resolution
inHg
0.0001
Diff. inHg
0.0001
mbar
0.01
Diff. mbar
0.01
psi
0.001
Diff. psi
0.001
mmHg
0.01
Diff. mmHg
0.01
kpa
0.001
Diff. kpa
0.001
Feet
1
Meters
0.1
knots
0.1
km/hr
0.1
[19]
Ps2 Target value
The target value that the user desires to achieve on the Ps2 output is displayed here. When the Ps2
output is in Control mode, the 6600-NG will automatically adjust the Ps2 Actual value to match the Ps2
Target value. The resolution of the Ps2 target value is the same as the resolution of the Ps2 Actual value.
How the user can change the Ps2 Target value is described in Section 3.xx.
[20]
Ps2-Rate units
The Ps2-Rate units are typically the Ps2 units per minute. If Ps2 units are inHg then the rate units are
inHg/min. However, there are two exceptions as shown in the table below. Ps2-Rate units cannot be
changed by the user.
Exceptions
Ps2 units
Ps2-Rate units
Meters
meters/sec
km/hr
km/hr/sec
[21]
Ps2-Rate Actual value