6600-NG User’s Manual
125-9110A
Page 55
7.
Leak Timers
8.
Calibration
9.
Encoder
When the
FUNC
key is pressed, the Lower section of the screen appears as shown below. The specific
function can be selected by pressing the related number-key.
Figure 3.31 : Functions
3.10.1
VIEW LIMITS
The 6600-NG has eight user-programmable limits. These are used to prevent incorrect entry of target
values. These limits are also checked continuously when the outputs are in Control mode. If any limit is
exceeded, the 6600-NG puts all outputs into Measure mode and displays an error condition.
Select ‘
1
’ in the Functions menu and the screen appears as shown below.
Figure 3.32 : View Limits
The details of each limit are provided in Section 3.10.2 (Modify Limits).
Note: Limit values cannot be modified in the “View Limits” screen.
3.10.2
MODIFY LIMITS
The eight user-programmable limits can be modified by selecting ‘
2
’ in the Functions menu. Access to the
‘Modify Limits’ function is protected by means of a password. The following screen will appear.
View Limits
1) Max knots: 400.0
5) Max feet:
52000
2) Min knots: -50.0
6) Min feet:
-2000
3) Max knots/m: 250.0
7) Max feet/m:
3000
4) Max Mach: 1.000
8) Max Dfin:
30
Press
CANC
to exit
Functions
1)
View Limits
4)
Run Profile
7)
Leak Timers
2)
Modilfy Limits
5)
Load Profile
8)
Calibration
3)
Brightness
6)
Ht. correction
9)
Encoder
Press
CANC
to exit