3)
Max knots/min:
This limit can be set between 50 and 500 knots/min. It defines the maximum
rate of change of airspeed. However, it does NOT define the maximum rate of change of Pt-
pressure in pressure units. (See note below). The factory setting is 250 knots/min.
Note: In pressure units, Pt, Ps2 and Ps1 Rate Targets can be set between 0 and 30 inHg/min.
4)
Max Mach:
This limit can be set between 0.5 and 3.0 Mach. The factory setting is 1.000 Mach.
5)
Max feet:
This limit can be set between 5,000 and 100,000 feet. It defines the maximum
altitude that can be controlled. It also defines the minimum Ps1 pressure that can be controlled.
The factory setting is 52,000 feet.
6)
Min feet:
This limit can be set between -2,000 and 0 feet. It defines the minimum altitude
that can be controlled. It also defines the maximum Ps1 pressure that can be controlled. The
factory setting is -2,000 feet.
7)
Max feet/min:
This limit can be set between 1,000 and 50,000 feet/min. It defines the maximum
altitude rate that can be controlled. However, it does NOT define the maximum rate of change of
Ps1-pressure in pressure units. (See note below).
Note: In pressure units, Ps1-Rate targets can be set between 0 and 30 inHg/min.
8)
Max Dfin:
This limit can be set between 1 and 30 inHg. It defines the maximum differential
pressure (plus or minus) permissible between Ps1 and Ps2.
3.10.3
ADJUST DISPLAY BRIGHTNESS
The brightness of the display can be adjusted by selecting ‘
3
’ in the Functions menu. The screen will then
appear as shown below.
Figure 3.36 : Adjust Brightness
Use the Arrow keys to adjust the brightness. On power-up the brightness level is always set to 15.
3.10.4
RUN PROFILE
Profiles are explained in detail in Section 4. A profile is a pre-programmed set of parameters, usually
based on an aircraft’s AMM, which allows the user to perform a test without having to enter all the
parameters. Each profile can have up to 50 points, where each point defines all the 12 parameters that are
Adjust Brightness
Min value 1 ; Max value 16
Use keys to adjust brightness level:
Press
CANC
to exit
8