6600-NG User’s Manual
125-9110A
Page 59
In the Lower section, the profile number (10.1) will be blinking (waiting for
GO
or
CANC
). The name of
the profile ’Test-1’ is displayed to the right of the profile number. Do NOT press
GO
or
CANC
. Instead,
press the
Up-Arrow
key to move to point number 2 of the profile. The screen will appear as follows.
Figure 3.39 : Run Profile (10.2 Blinking)
For this point, units and modes remain the same as point 1, but the Target values and the Rate Target
values have changed. In the Lower section, ’10.2’ is blinking. Keep pressing the
Up-Arrow
key to scroll
through all the points of the profile. Use the
Down-Arrow
key to go to the previous point. The last point
of the profile is point number 13.
You can cancel out of a profile at any time by pressing
CANC
. The last effective parameters will remain
valid even after you cancel out of the profile. You can enter a profile at any point (like 10.6).
Cancel out of Profile 10 by pressing
CANC
. Press
FUNC
and then ‘
4
’ to return to the ‘Run Profile’ screen
and then enter ’10.1’ followed by
ENTER
. Again, ’10.1’ will be blinking and all 12 parameters will be
setup. Now, press
GO
to execute the profile. (Before doing this, please ensure that all three ports are
closed and all three Vent valves are closed).
Wait for the 6600-NG to achieve the targets set in 10.1. The screen will appear as shown below.
5.7
110.0
Pt inHg
Pt
Ps2
Ps1
Control
knots/min
0.0
155.0
Dfin
Feet
0.0001
45
knots
0.1500
0
inHg/min
Feet/min
0.000
0
4.100
2500
Control
Control
AC
92%
Hide/Show Ps2
000
Run Profile
Running Profile :
Use keys for more points;
GO
to execute;
CANC
to exit profile
10.2
Test-1