Figure 3.12 : Jog the Pt Target value
In this screen, the Upper section has a new symbol (with Up & Down arrows) to the left of the Pt Target
value field. This indicates that the Pt Target value can be jogged up or down repeatedly, in steps of 1
knot, using the Arrow keys, until
CANC
is pressed. In this case, since the
Up-Arrow
key was pressed,
the Pt Target value was incremented to 21.0 knots. Press
Up-Arrow
one more time and the value will
change to 22.0. Press
Down-Arrow
two times and the value decrements to 20.0.
Note: It is not possible to Jog a Target value if it is blinking.
The incremental value for the Jog feature varies depending on Pt units and is shown in the table below.
Pt units
Jog increment
knots
1.0
Mach
0.001
km/hr
1.0
mph
1.0
Pt inHg
0.001
Qc inHg
0.001
Pt mbar
0.01
Qc mbar
0.01
Pt psi
0.001
Qc psi
0.001
Pt mmHg
0.01
Qc mmHg
0.01
3.9
21.0
Pt inHg
Pt
Ps2
Ps1
Measure
knots/min
0.0
150.0
inHg
inHg
29.9213
29.9213
knots
30.0000
30.0000
inHg/min
inHg/min
0.000
0.000
4.000
4.000
Measure
Measure
AC
92%
Hide/Show Ps2
000
Messages