Lake Shore Model 370 AC Resistance Bridge User’s Manual
4-34
Operation
Default Parameter Values (Continued)
The next screen appears to show the input firmware revision date and as a prompt for clearing user curve memory.
Input Code: 1.0
Select With °®
Clear Curves: No
Use the
VW
keys to select Yes to clear curves and No to continue without clearing. Press
Enter
to accept the new
selection and return to the normal display. Press
Escape
to cancel the new selection and return to the normal display.
Table 4-1. Default Parameter Values
Alarm and Relay
Alarm ..................................................... Off
Alarm Audible ....................................... Off
Relay Low ............................................. Off
Relay High ............................................. Off
Analog Output
Analog Output 1 .................................... Off
Analog Output 2 .................................... Off
Computer Interface
Baud ..................................................... 9600
IEEE Address .......................................... 12
IEEE Terminators ............................. CR/LF
Control Setup
Control Channel ......................................... 1
Setpoint Units .................................... Ohms
Control Mode ...................................... Open
Heater Range Limit......................... 100 mA
Setpoint Change Pause Time ............. 25 sec
Control Filter ......................................... Off
Heater Display ................................. Current
Setpoint Ramp ....................................... Off
Heater Resistance .......................... 100 ohm
Heater Polarity ............................... Unipolar
Display Format
Number of Locations ................................. 1
Location 1 Channel .............................. Scan
Location 1 Data Source ..................... Ohms
Display Resolution .................................... 6
Brightness ............................................ 75%
Excitation and Range
Excitation Mode ............................. Voltage
Excitation ........................................ 632 mV
Resistance Range ...................... 63.2 Mohm
Autorange .............................................. Off
Input Setup
Scan Channel ............................................. 1
Autoscan ................................................ Off
Scan Dwell Time ............................... 10 sec
Change Pause Time ............................. 3 sec
Curve Number ............................. No Curve
Temperature Coefficient ....................... Neg
Channel ................................................... On
Heater
Heater Range ......................................... Off
Instrument Setup
Frequency ......................................... 13.7 Hz
Common Mode Reduction ....................... On
Guard Drive ............................................. Off
Keypad Locking
Mode ..............................................Unlocked
Lock Code ............................................... 123
Linear and Filter
Channel ....................................................... 1
Equation ............................................. MX+B
Slope (M) ........................................... 1.0000
X Source .............................................. Ohms
B Source .............................................. Value
Offset (B) ........................................... 0.0000
Filter ........................................................ Off
PID and Manual Heater Setting
Proportional (P) ......................................... 10
Integral (I) ........................................... 20 sec
Derivative (D) ....................................... 0 sec
Manual .............................................. 0.000%
Remote/Local
Remote/Local ....................................... Local
Setpoint
Setpoint Value .................................... 0.0000
Zone Settings – All Channels
Setpoint Limit .................................. 0.000 K
Proportional (P) ......................................... 10
Integral (I) ........................................... 20 sec
Derivative (D) ....................................... 0 sec
Manual Output .................................. 0.000%
Heater Range ........................................... Off
Relay Low ............................................... Off
Relay High .............................................. Off
Analog Output 1 .................................. 0.00%
Analog Output 2 .................................. 0.00%