6 | Function description
Temporarily editing the soldering profile in the [Rework] tab
6.5.3.3 The [Heating setting] tabulator under the [Rework] tabulator
Under tab [Heater config], chart (4) with the heating curves will be displayed in the
middle of the screen and, below, the button row for the [Process automation ] (6).
The heating curves in the middle of the screen can be changed. For this purpose,
please read Chapter The chart in the [Rework] tabulator. Also the buttons in row
[Process automation] (6) at the bottom can be always changed. For this purpose,
please also read Chapter The [Process Automation] button row [
buttons to enable or disable process steps.
For all changes made in tab [Rework], the following applies: changes are accepted
but cannot be saved. If you switch from tab [Rework] to another tab, all changes
will be lost.
Combined
Rework
Archive
User administration
Profile management
Administration
Manual mode
Soldering
Desoldering
Change all zones
Search
Heater config
Information
Top
Placement
Inspection
Soldering
Inspection
Desoldering
Soldering
Desoldering
Synchronize
Process automation
Bottom
START/REFERENCE
Synchronize
Time
If you want to change the heating settings specified in the soldering profile,
deselect button [Combined] and instead select buttons [Soldering] or [Desolder-
ing]. Buttons [Soldering] or [Desolderingcan each have their own heating curve in-
cluding detailed heating settings or, by selecting button [Synchronize], the heating
curve will be identical for both soldering processes. Click button [Synchronize] to
change the desoldering heating curve according to the values of the soldering heat-
ing curve. The displayed heating settings are valid for the highlighted soldering
curve.
The parameters in tab [Heater config]
[Change all zones]: If this button is selected, all [Tinit] heating phases up to T4 will
be displayed in blue in tab [Heater config] as well as in chart (4). The parameters in
tab [Heater config] will now apply to all heating phases. If button [Change all zones]
is disabled, different heating parameters can be assigned to each of the four heat-
ing phases.
The following parameters can be changed in tab [Heater config]: