2 | Technical data
Axis system
Designation
Rated output (kW) at 230 V
1.6 (4 x 0.4)
Top radiator
Designation
Heating type
Hybrid radiator, IR radiator in ceramic
seat, medium wave, with blower
Component handling
Built-in pipette, motorised
Dimensions (width x depth, mm)
80 x 80
Rated output (kW) at 230 V
0.9, infrared
Baffle insert (mm)
30 x 30, 45 x 45 (always available as op-
tional equipment)
Temperature sensors
Designation
Sensor type
AccuTC sheath thermocouple, type K
Additional inputs for K-type thermo-
couples
1
2.6 Axis system
Designation
Type
Precision rail guide with step motors
Axles
Z pipette
Repeat accuracy (µm)
± 25
Nozzle diameter (mm)
5 and 10, optional 3.3, 2 and 1
2.7 Cameras
Visionbox pick-and-place camera
Designation
Type
Colour camera
Resolution (Mpixel)
5
Interface
GigE
Lighting
White diffuse circuit board lighting
Red diffuse component lighting
Laser pointer
Laser Class 2
2.8 PC system requirements
For the PC configuration required for your Rework System, refer to the PDF docu-
ment
3BA00212 “PC-Konfigurationsempfehlung_Ersa-IRSOFT-HRSoft-ImageDoc”. This
document can found on the Ersa Rework USB stick (3BA000149).