5 | Commissioning
Calibrate the pipette distances and the optical axle
Fig. 12:
Use a 2.5 mm Allen wrench and slightly loosen
m)Rotate the screw at the left behind the Visionbox with a 3 mm Allen wrench, in
order to correct the optical axle in X direction, see the picture below. Observe
the screen, the margins of the calibration target in Y direction must show a uni-
form margin.
Fig. 13:
To correct in X direction, use a 3 mm Allen wrench, while observing the camera image.
n) Slide both the heating head and the Visionbox to the right.
o) Rotate the central screw of the rail behind the Visionbox with a 3 mm Allen
wrench, in order to correct the optical axle in Y direction, see the picture be-
low. After rotation, slide the Visionbox to the left below the camera and verify
the outcome on the screen. Repeat this process until the calibration target is
displayed congruently on the background and with a uniform border.
Ersa GmbH
Operating_instructions HR 500 DE 3BA00246-01 | Rev. 1
48 / 124