PRODUCT INFORMATION
INDEX
DATE
Dep. 2
IO-G-M-00-061e C
January 2016
MAINTENANCE OF NATURAL GAS ENGINE
SFGLD 1800 RPM PRIME
4/7
Job Interval
Job
Description
E1 1.200
h
- Analyse waste oil
- Change oil filters
- Change oil
KOHLER
MOTOROIL (oil sump and cooler)
- Clean the oil centrifuge filter, film-thickness measurement and change
the paper filter
- Clean the metallic sponge of the oil purifier
- Measure crankcase pressure
- Check air/fuel ratio
- Adjust
air/fuel ratio to full load (*), if necessary
- Inspect the air filters
- Adjustment of rocker arms and valve lifters. Measure valve height
- Check safety devices and connections: temperature and pressure switches and
probes
- Check battery acid level
- Check battery and starter connections
- Inspection of
high voltage wires of the ignition system
- Change the filter of crankcase gases recirculation system and clean this circuit (*
A
*)
E3
4,800 h
or
once a year
- Verify the ignition timing
- Check damper temperature
- Change air filters
- Check gaskets in the rocker arm covers
- Disassemble, clean and adjust all the speed and ignition pick-ups
- Measure the exhaust back-pressure
- Change coolant
- Verify the tightening torque of knocking sensors on stud head (20 Nm)
- Check the axial clearance, radial clearance and condition of the turbocharger vanes
NOTE
- The spark plugs change must be made attending the IO-G-M-33-007 product information*.
*It’s recommend to carry out a borescope inspection and do a compression test when changing spark
plugs
- Ask
Kohler
to use another oil that it is not
KOHLER
MOTOROIL.
5.1.8