PRODUCT INFORMATION
INDEX
DATE
Dep. 2
IO-G-M-00-061e C
January 2016
MAINTENANCE OF NATURAL GAS ENGINE
SFGLD 1800 RPM PRIME
3/7
ROUTINE MAINTENANCE (Type "E")
Minor Jobs
Job Interval
Job
Description
EO Daily
(Operations to be performed with the engine stopped)
- Vent the coolant circuit. Check automatic vent valves
- Drain condensates out of the exhaust Y-pipe
- Check oil pressure and temperature during the pre-lubrication phase
- With the dipstick, check for a possible increase of the oil level in the oil pan due to
coolant leaks
- Verify oil heating with the pre-heater, if necessary
- Check the oil level of the pneumatic starter lubricator, if necessary
- Clean the engine and its surrounding
(Operations to be carried out with the engine idling)
- Check oil level
(Operations to be carried out with the engine stabilized)
- Check coolant level / pressure. Vent circuits
- Check oil pressure
- Inspect the air filter plugging level (reset the pilot first)
- Check oil, coolant and exhaust gases temperature
- Check the filter cleaning state pilot of the crankcase gases recirculation system.
Control the crankcase pressure (*
A
*)
- Record engine parameters on a regular basis
- Revision of the operational stability and unusual noise
- Inspect for leaks in fuel, coolant, oil and exhaust gases
5.1.7
O&M_2.002211.810_A_10_2016