PRODUCT INFORMATION
INDEX
DATE
Dep. 2
IO-G-M-33-010e
June 2013
INSTALLATION AND OPERATION MANUAL - GIS IGNITION UNIT
DISPLAY
8/14
3.1.3. Ignition
This view provides information related to the firing in each cylinder
Fig. 9 – Screenshot of secondary voltage
-
Secondary Voltage:
it is an estimate value of the voltage required to generate the spark in the spark plug
gap.
-
Misfire Indicator:
This LED gives information on where the misfires have occurred in the different
cylinders:
o
Grey:
There are no misfires.
o
Yellow: has previously been misfiring but currently there are none.
o
Red: There are misfires.
3.1.4. Energy
This view displays cylinder-specific spark characteristics. The value of two parameters is shown for each cylinder:
-
Spark Duration
: spark duration in microseconds
-
Energy Output
: firing energy applied to each cylinder to generate the spark
4.1.32
O&M_2.002211.810_A_10_2016