MAINTENANCE OF SPARK PLUGS. OVERVIEW
2/2
3. GUIDELINES ON SPARK PLUG REPLACEMENT
1200rpm 1500rpm 1800rpm
REF HOURS
REFERENCE
DOCUMENT
HOURS
REFERENCE
DOCUMENT
HOURS
REFERENCE
DOCUMENT
FG/ FGLD natural gas
1250
IO-G-M-00-073
1000
IO-G-M-00-074
5000
4000
FG/ FGLD biogas (*)
1250
IO-G-M-00-073
1000
IO-G-M-00-074
5000
4000
SFGLD
natural
gas
4500 IO-G-M-00-067 3750 IO-G-M-00-065 3000 IO-G-M-00-066
SFGLD natural gas ISLAND
7500
IO-G-M-00-057
6000
IO-G-M-00-038
4500
IO-G-M-00-058
SFGLD natural gas PRIME
1000 IO-G-M-00-061
SFGLD natural gas STAND-BY
1000 IO-G-M-00-019
SFGLD biogas (*)
1250
IO-G-M-00-067
1000
IO-G-M-00-065
1000
IO-G-M-00-066
4500 3750 3000
SFGLD natural gas LCR 9,3:1
2500
IO-G-M-00-034
2000
IO-G-M-00-024
1600
IO-G-M-00-035
5000 4000 3200
SFGLD natural gas LCR 9,3:1 ISLAND
2500
IO-G-M-00-079
2000
IO-G-M-00-078
7500 6000
SFGLD natural gas LCR 8:1
2000
IO-G-M-00-024 1600 IO-G-M-00-035
SFGLD natural gas LCR 8:1 ISLAND
2500
IO-G-M-00-079 2000 IO-G-M-00-078
SFGLD syngas (**)
800
IO-G-M-00-042
700
IO-G-M-00-003
600
IO-G-M-00-043
4000 3500 3000
SFGRD natural gas
1000 IO-G-M-00-062
SFGRD natural gas PRIME
1200 IO-G-M-00-063
SFGRD natural gas STAND-BY
1000 IO-G-M-00-064
HGM natural gas
3500
IO-G-M-00-072
3500
IO-G-M-00-070
3500 IO-G-M-00-071
HGM
biogas
3500 IO-G-M-00-072 3500 IO-G-M-00-070 3500 IO-G-M-00-071
SFGM natural gas
3000
IO-G-M-00-068
3000 IO-G-M-00-069
SFGM natural gas ISLAND
4800 IO-G-M-00-051 4800 IO-G-M-00-059
SFGM biogas
3000
IO-G-M-00-068
3000 IO-G-M-00-069
SFGM propane
3000
IO-G-M-00-040
3000 IO-G-M-00-041
SFE ethanol
4800 IO-L-M-00-001
NOTE: In most cases, the times specified in this document have been defined to coincide with maintenance
activities E.
In the cases of engines operating at variable speed, it must be apply the value of the highest speed.
(*) If the variation of biogas (LHV) is higher than 10%, it is recommended use the spark plug reference
(**) If the gas is very dirty, it is recommended use the spark plug reference
5.2.36