9.5.5.4. Switching between „normally open“ (NO) and „normally closed“ (NC) mode
The network relay module has two jumpers to define the operating mode of the internal relays.
By default the relays/outputs of the module work a so-called „normally open“ mode. On an access with a valid
authentication the relay closes to trigger the connected application (door) for the configured time.
This can be switched to a permanently closed state („normally closed“). On a valid access the relay/output is
then opened.
9.5.5.5. Configuration of IP Wall Reader and network relay module
The configuration of the two devices is done via the web interface of the network relay module. This
configuration is based on the same structure as on the Kentix AccessPoint.
To configure reader and module please follow the steps as described later in this manual.
9.5.6. AccessPoint
To mount the AccessPoint simply fix the supplied mounting bracket to wall or ceiling and attach the AccessPoint
to it. Connect the AccessPoint to a PoE-enabled switch.
Please note that the maximum distance to the DoorLock-devices must not exceed 25 meters. Otherwise the
radio connection is not guaranteed.