Model 2700 Multimeter/Switch System User’s Manual
Common Commands
12-3
A *IDN? — identification query
Reads identification code
The identification code includes the manufacturer, model number, serial number, and
firmware revision levels and is sent in the following format:
KEITHLEY INSTRUMENTS INC., Model 2700, xxxxxxx, yyyyy/zzz
Where:
xxxxxxx is the serial number.
yyyyy/zzzzz is the firmware revision levels of the digital board ROM and
display board ROM.
B *OPC
⎯
Operation Complete
Set the OPC bit in the standard event register
after all pending commands are complete.
Description
After the *OPC command is sent, the Operation Complete bit (bit B0) of the Standard
Event Status Register will set immediately after the last pending command is completed.
If the corresponding bit (Bit B0) in the Standard Event Enable Register and Bit 5 (Event
Summary Bit) of the Service Request Enable Register is set, the RQS/MSS (Request for
Service/Master Summary Status) bit in the Status Byte Register will set.
When used with the immediate initiation command (:INITiate), the OPC bit in the
Standard Event Status Register will not set until the Model 2700 goes back into the idle
state. The :INIT command operation is not considered finished until the Model 2700 goes
back into the idle state. See the description for *WAI for more information on command
execution.
Programing example – The first group of commands program send the *OPC command
after the :INITiate command and verifies that the OPC bit in the Standard Event Status
Register does not set while the instrument continues to make measurements (not in idle).
The second group of commands return the Model 2700 to the idle state and verifies that
the OPC bit did set.
SYST:PRES
‘ Returns 2700 to default setup.
INIT:CONT OFF
‘ Disables continuous initiation.
ABORt
‘ Aborts operation. Places 2700 in idle.
INIT:IMM
‘ Initiate one trigger cycle.
*OPC
‘ Sends the OPC command.
*ESR?
‘ Reads the Standard Event Status Register.
After addressing the Model 2700 to talk, the returned value of 0 denotes that the bit (bit 0)
is not set indicating that the :INITiate operation is not complete.
ABORt
‘ Aborts operation. Places 2700 in idle.
*ESR?
‘ Reads the Standard Event Status Register.
Содержание 2700
Страница 3: ......
Страница 7: ......
Страница 197: ...5 24 Rel Math Ratio Channel Average dB Model 2700 Multimeter Switch System User s Manual...
Страница 213: ...6 16 Buffer Model 2700 Multimeter Switch System User s Manual...
Страница 289: ...9 18 Limits and Digital I O Model 2700 Multimeter Switch System User s Manual...
Страница 335: ...11 24 Status Structure Model 2700 Multimeter Switch System User s Manual...
Страница 336: ...12 CommonCommands...
Страница 344: ...13 SCPISignalOriented MeasurementCommands...
Страница 353: ...13 10 SCPI Signal Oriented Commands Model 2700 Multimeter Switch System User s Manual...
Страница 363: ...14 10 FORMat and Misc SYSTem Commands Model 2700 Multimeter Switch System User s Manual...
Страница 364: ...15 SCPIReferenceTables...
Страница 391: ...A 2 Specifications Model 2700 Multimeter Switch System User s Manual...
Страница 392: ...Model 2700 Multimeter Switch System User s Manual Specifications A 3...
Страница 393: ...A 4 Specifications Model 2700 Multimeter Switch System User s Manual...
Страница 394: ...Model 2700 Multimeter Switch System User s Manual Specifications A 5...
Страница 395: ...A 6 Specifications Model 2700 Multimeter Switch System User s Manual...
Страница 400: ...B Model7700ConnectionGuide...
Страница 411: ...B 12 Model 7700 Connection Guide Model 2700 Multimeter Switch System User s Manual...
Страница 412: ...C StatusandErrorMessages...
Страница 419: ...C 8 Status and Error Messages Model 2700 Multimeter Switch System User s Manual...
Страница 420: ...D SignalProcessing SequenceandDataFlow...
Страница 433: ...D 14 Signal Processing Sequence and Data Flow Model 2700 Multimeter Switch System User s Manual...
Страница 434: ...E MeasurementConsiderations...
Страница 443: ...E 10 Measurement Considerations Model 2700 Multimeter Switch System User s Manual...
Страница 454: ...G IEEE 488BusOverview...
Страница 469: ...G 16 IEEE 488 Bus Overview Model 2700 Multimeter Switch System User s Manual...
Страница 470: ...H KE2700InstrumentDriver Examples...
Страница 489: ...H 20 KE2700 Instrument Driver Examples Model 2700 Multimeter Switch System User s Manual...
Страница 499: ......