Model 2700 Multimeter/Switch System User’s Manual
Status Structure
11-17
Questionable event register
The used bits of the Questionable Event Register (
) are described as follows:
•
Bits B0 through B3
— Not used.
•
Bit B4, Temperature Summary (Temp)
— Set bit indicates that an invalid refer-
ence junction measurement has occurred for thermocouple temperature
measurements.
•
Bits B5, B6 and B7
— Not used.
•
Bit B8, Calibration Summary (Cal)
— Set bit indicates that an invalid calibration
constant was detected during the power-up sequence. The instrument will instead
use a default calibration constant. This error will clear after successful calibration
of the instrument.
•
Bits B9 through B13
— Not used.
•
Bit B14, Command Warning (Warn)
— Set bit indicates that a Signal Oriented
Measurement Command parameter has been ignored.
•
Bit B15
— Not used.
NOTE
Whenever a questionable event occurs, the ERR annunciator will turn on. The
annunciator will turn off when the questionable event clears.
Figure 11-7
Questionable event status
(B13 - B9)
(B14)
(B8)
(B15)
OR
Questionable
Condition
Register
Questionable
Event Enable
Register
Warn = Command Warning
Cal = Calibration Summary
Temp = Temperature Summary
& = Logical AND
OR = Logical OR
0
(B13 - B9)
(B14)
(B8)
(B15)
0
Warn
Cal
Questionable
Event
Register
(B13 - B9)
(B14)
(B8)
(B15)
To
Questionable
Summary Bit of
Status (QSB)
Byte Register
(B7 - B5)
(B7 - B5)
(B7 - B5)
Warn
Cal
0
Warn
Cal
(B4)
Temp
(B4)
Temp
(B3 - B0)
(B3 - B0)
(B3 - B0)
(B4)
Temp
&
&
&
&
Содержание 2700
Страница 3: ......
Страница 7: ......
Страница 197: ...5 24 Rel Math Ratio Channel Average dB Model 2700 Multimeter Switch System User s Manual...
Страница 213: ...6 16 Buffer Model 2700 Multimeter Switch System User s Manual...
Страница 289: ...9 18 Limits and Digital I O Model 2700 Multimeter Switch System User s Manual...
Страница 335: ...11 24 Status Structure Model 2700 Multimeter Switch System User s Manual...
Страница 336: ...12 CommonCommands...
Страница 344: ...13 SCPISignalOriented MeasurementCommands...
Страница 353: ...13 10 SCPI Signal Oriented Commands Model 2700 Multimeter Switch System User s Manual...
Страница 363: ...14 10 FORMat and Misc SYSTem Commands Model 2700 Multimeter Switch System User s Manual...
Страница 364: ...15 SCPIReferenceTables...
Страница 391: ...A 2 Specifications Model 2700 Multimeter Switch System User s Manual...
Страница 392: ...Model 2700 Multimeter Switch System User s Manual Specifications A 3...
Страница 393: ...A 4 Specifications Model 2700 Multimeter Switch System User s Manual...
Страница 394: ...Model 2700 Multimeter Switch System User s Manual Specifications A 5...
Страница 395: ...A 6 Specifications Model 2700 Multimeter Switch System User s Manual...
Страница 400: ...B Model7700ConnectionGuide...
Страница 411: ...B 12 Model 7700 Connection Guide Model 2700 Multimeter Switch System User s Manual...
Страница 412: ...C StatusandErrorMessages...
Страница 419: ...C 8 Status and Error Messages Model 2700 Multimeter Switch System User s Manual...
Страница 420: ...D SignalProcessing SequenceandDataFlow...
Страница 433: ...D 14 Signal Processing Sequence and Data Flow Model 2700 Multimeter Switch System User s Manual...
Страница 434: ...E MeasurementConsiderations...
Страница 443: ...E 10 Measurement Considerations Model 2700 Multimeter Switch System User s Manual...
Страница 454: ...G IEEE 488BusOverview...
Страница 469: ...G 16 IEEE 488 Bus Overview Model 2700 Multimeter Switch System User s Manual...
Страница 470: ...H KE2700InstrumentDriver Examples...
Страница 489: ...H 20 KE2700 Instrument Driver Examples Model 2700 Multimeter Switch System User s Manual...
Страница 499: ......