4.1.2.14. Reduction Adapter of Ma-
terial Discharging
The adapter of the material discharging is lo-
cated at end of the discharge cone (1) and
used to connect the coupling on the outlet of
the silo vehicle’s discharge cone. The disc-
harge cone is controlled by the open-close
valve (2) on the adapter of material dischar-
ging.
Material discharging reduction connection
Opening or loosening a hose co-
upling during the emptying proce-
dure will cause the product to
spray around and the material hose could
whip back and forth. The whipping hose
could cause injuries.
Never loosen or open a hose coupling that
is under pressure.
Tighten the hose coupling firmly before
discharging.
Always use the blind cover to
close the hose coupling after use.
It acts as an additional shut-off ele-
ment to avoid product loss.
4.1.2.15. On Off Butterfly Valve Lo-
cated on Material Discharge
Connection
This valve is used to open or close the con-
nection of material discharging. The locking
arm (1) prevents unwanted, inadvertent shif-
ting in the butterfly valve arm (2).
Butterfly valve
To move the valve with the arm of the butterfly
valve, firstly the lock arm should be released.
After the valve is adjusted and the arm of the
butterfly valve is released, the lock arm is re-
locked. When the discharge begins, the valve
must be put into fully open position, dischar-
ging when the valve is not fully opened causes
valve gasket to wear.
Make sure that the lock arm is
always in locked position.