45
/
88
4.1.2.3. Fluidiser Air Line
The fluidiser air line mixes the products with
the air to prevent the product being accumula-
ted at the hole of the discharge cone by relea-
sing the accumulated product during unloa-
ding, thus the product discharges much more
freely and easily. The fluidiser air also inhibits
clogging at the hole of the discharge cone. For
this reason, connect the fluidiser air line to its
location on the discharge cone during unloa-
ding operation.
Fluidiser air line
4.1.2.4. Fluidiser Air Line Valve
The fluidiser air line stop valve is located on
the air battery and it controls the air which pas-
ses into the fluidiser air line. The position of the
lever (2) which is seen in the picture is the
open position. To stop the compressed air
which passes to the line, you can bring the le-
ver to the closed position by turning 90 deg-
rees counter clockwise.
Fluidiser air line and valve
4.1.2.5. Jet Air Line
Jet air line (1) supports the material to disc-
harge from the discharge hole. To be able to
use the jet air, the discharge cone which is
supplied with the vehicle has to be connected
to the discharging cone. One end of the jet air
is connected to the air battery, during unloa-
ding connect the other end of the line to its
place (2) on the discharge cone. The material
which is mixed and sent to the discharge cone
by fluidizer air, discharges quickly by the help
of the jet air.
Jet air line
4.1.2.5.1. Jet Air Line Valve
The jet air line stop valve is located on the air
battery and it controls the air which passes into
the jet air line. The position of the lever (3)
which is seen in the picture is the open posi-
tion. To stop the compressed air which passes
to the line, you can bring the lever to the closed
position by turning 90 degrees counter
clockwise.
Jet air line valve