Do not raise the fully loaded silo
tank completely. First raise the
silo tank in first of the three
steps of the piston, after the half of the
silo tank is emptied, raise completely.
Finish discharging
•
Open and close the stop valve for
fluidiser air several times.
•
Stop the compressed air supply by
switching off the compressor.
•
Close the on-off valve on the ma-
terial coupling.
•
Close the stop valves of the top air
and fluidiser air.
Terminate discharging
•
Lower the silo tank slowly.
•
Slowly ventilate the silo tank by
means of the venting valve (8). Le-
ave the ventilation valve open until
the next time the tank is loaded in
order to avoid vacuum damage.
Ventilation valve
•
Wear goggles when relea-
sing the remaining pressure.
•
While the silo tank is empty,
leave the ventilation valve open in
order to avoid vacuum damage.
•
Uncouple the air lines and the mate-
rial hose.
•
Retract the folding handrail.
•
Retract the rear landing legs.
•
Set the suspension to the drive po-
sition.
7.2.4.1. Discharge With Hydrau-
lic Pump
For discharging procedure firstly a comp-
ressor must be provided (a compressor
which generates pressure of 2 bar in the
tank, has air intake flow of minimum 500-
600 m
3
/ h, has the power of 40 KW is nee-
ded.)
In order for the pump to work, an electrical
connection must be made to the tractor with
the NATO socket in the socket holder area.
Connection coupling
Connection of the compressor to the vehic-
le's air line; It is made with the connecting
coupling (1) in front of the side air line. The
air line is connected to the air battery loca-
ted at the rear of the vehicle with a coupling.
Side air line
The discharge elbow should be coupled to
the discharge cone end.
While the air ventilation valve, the fluidiza-
tion valve going to the discharge cone, the
Содержание SILO Series