![Juniper JUNOSE 11.2 Скачать руководство пользователя страница 97](http://html1.mh-extra.com/html/juniper/junose-11-2/junose-11-2_configuration-manual_2032833097.webp)
The following commands cause the router to retain the VBR-RT service category for the
PVC because it is still the most recent explicitly specified value for this attribute. The
router takes the values for the other attributes from the VC class my-premium-class.
host1(config)#
interface atm 2/0.200
host1(config-subif)#
pvc 200 0/200
host1(config-subif-vc)#
class-vc my-premium-class
host1(config-subif-vc)#
exit
Example 2: Changing the Encapsulation Method in the VC Class
The following commands change the value for the encapsulation method in the VC class
my-premium-class from
aal5autoconfig
to
aal5snap
. As a result, the router now uses
aal5snap
instead of
aal5autoconfig
as the encapsulation method for the PVCs to which
this VC class is assigned.
host1(config)#
vc-class atm my-premium-class
host1(config-vc-class)#
encapsulation aal5snap
host1(config-vc-class)#
exit
Example 3: Effect of Using the atm pvc Command
The following commands, which attempt to assign the my-premium-class VC class to
a PVC originally created with the
atm pvc
command, have no effect. The router interprets
all attribute values specified with the
atm pvc
command as explicitly specified values,
and therefore takes the values for these attributes from the
atm pvc
command instead
of from the VC class. As a result, the router continues to use
aal5mux ip
as the
encapsulation method for this PVC instead of the encapsulation method specified in the
VC class my-premium-class.
host1(config)#
interface atm 2/0.300
host1(config-subif)#
atm pvc 300 0 300 aal5mux ip
host1(config-subif)#
pvc 300 0/300
host1(config-subif-vc)#
class-vc my-premium-class
host1(config-subif-vc)#
exit
Example 4: Overriding RADIUS Values
If RADIUS is configured to provide traffic parameters for PVCs, a more recent, explicitly
specified change in the VC class associated with that PVC overrides the PVC values
applied through RADIUS.
In the following example, assume that RADIUS has been configured to apply a service
category of CBR with a PCR of 400 Kbps to the PVC. Initially, the PVC uses the service
category configured in my-premium-class, CBR with a PCR of 200 Kbps. However, when
the subscriber logs in through RADIUS, the router applies the RADIUS-configured service
category, CBR with a PCR of 400 Kbps.
While the subscriber is still logged in, my-premium-class is modified to change the service
category to CBR with a PCR of 600 Kbps. Because this VC class modification results in
the most recent, explicitly specified value for the service category, the router now uses
CBR with a PCR of 600 Kbps as the service category for the PVC instead of the service
category configured through RADIUS.
host1(config)#
interface atm 2/0.200
host1(config-subif)#
pvc 200 0/200
65
Copyright © 2010, Juniper Networks, Inc.
Chapter 1: Configuring ATM
Содержание JUNOSE 11.2
Страница 6: ...Copyright 2010 Juniper Networks Inc vi ...
Страница 8: ...Copyright 2010 Juniper Networks Inc viii JunosE 11 2 x Link Layer Configuration Guide ...
Страница 26: ...Copyright 2010 Juniper Networks Inc xxvi JunosE 11 2 x Link Layer Configuration Guide ...
Страница 34: ...Copyright 2010 Juniper Networks Inc 2 JunosE 11 2 x Link Layer Configuration Guide ...
Страница 136: ...Copyright 2010 Juniper Networks Inc 104 JunosE 11 2 x Link Layer Configuration Guide ...
Страница 162: ...Copyright 2010 Juniper Networks Inc 130 JunosE 11 2 x Link Layer Configuration Guide ...
Страница 228: ...Copyright 2010 Juniper Networks Inc 196 JunosE 11 2 x Link Layer Configuration Guide ...
Страница 290: ...Copyright 2010 Juniper Networks Inc 258 JunosE 11 2 x Link Layer Configuration Guide ...
Страница 330: ...Copyright 2010 Juniper Networks Inc 298 JunosE 11 2 x Link Layer Configuration Guide ...
Страница 376: ...Copyright 2010 Juniper Networks Inc 344 JunosE 11 2 x Link Layer Configuration Guide ...
Страница 390: ...Copyright 2010 Juniper Networks Inc 358 JunosE 11 2 x Link Layer Configuration Guide ...
Страница 402: ...Copyright 2010 Juniper Networks Inc 370 JunosE 11 2 x Link Layer Configuration Guide ...
Страница 468: ...Copyright 2010 Juniper Networks Inc 436 JunosE 11 2 x Link Layer Configuration Guide ...
Страница 496: ...Copyright 2010 Juniper Networks Inc 464 JunosE 11 2 x Link Layer Configuration Guide ...
Страница 534: ...Copyright 2010 Juniper Networks Inc 502 JunosE 11 2 x Link Layer Configuration Guide ...
Страница 650: ...Copyright 2010 Juniper Networks Inc 618 JunosE 11 2 x Link Layer Configuration Guide ...
Страница 739: ...PART 2 Index Index on page 709 707 Copyright 2010 Juniper Networks Inc ...
Страница 740: ...Copyright 2010 Juniper Networks Inc 708 JunosE 11 2 x Link Layer Configuration Guide ...
Страница 772: ...Copyright 2010 Juniper Networks Inc 740 JunosE 11 2 x Link Layer Configuration Guide ...