Mirus for H2 Classic GrainGage
62
H2 Classic GrainGage Calibration
6. Select
Test Weight
and tap the next arrow .
7. Pour the grain sample into the hopper (to simulate
harvest). Ensure the isolation gate is open so the grain
drops into the GrainGage.
8. Enter the
Known
Test Weight
.
9. Tap
Click to run a sample
.
10. After you have run one sample 3–5 times, tap the next
arrow .
11. The final screen will display the recalibrated values.
Содержание HarvestMaster mirus H2
Страница 1: ......
Страница 7: ...CHAP TER ONE Mirus Ins tallation...
Страница 11: ...Mirus and GrainGage S etup CHAP TER T WO...
Страница 32: ...H2 Clas sic GrainGage Diagnos tic s and Aler t s CHAP TER THREE...
Страница 42: ...GrainGage Calibration CHAP TER FOUR...
Страница 71: ...Field Maps CHAP TER FIVE...
Страница 98: ...Har ves t Mode CHAP TER SIX...
Страница 111: ...Mirus for H2 Classic GrainGage 111 Harvest Mode 6 3 7 List View In List View you can see the data in the form of a chart...
Страница 120: ...Standard Grain Information APPENDIX A...
Страница 123: ...Troubleshooting APPENDIX B...
Страница 129: ...Limited Warrant y APPENDIX C...