background image

Mirus for H2 Classic GrainGage

                                                                                                                                                                                                      114

Harvest Mode

6.3.10  Configure Test Weight in Spatial Display

To set the minimum and maximum test weight, 

1.  Tap the Spatial Display icon 

 to display data in a heat map format.

2.  Select the 

Test Weight

 attribute. 

3.  Tap the gear icon 

 in the Attribute bar.

4.  Set the 

Minimum

 and 

Maximum 

Test Weight Settings.

5.  Tap the check icon  . 

Adjusting the minimum and maximum values helps to create a more detailed legend and define the scope 

of the graphs and maps. The narrower the minimum and maximum range, the more detailed the 

information displayed becomes.

Select the 

test weight 

attribute. 

Tap the gear 

icon. 

Set the minimum 

and maximum test 

weight.

Содержание HarvestMaster mirus H2

Страница 1: ......

Страница 2: ...nc All other trademarks are registered or recognized by their respective owners Disclaimer Information is subject to change without notice Cautions CAUTION This symbol indicates that failure to follow...

Страница 3: ...4 2 2 2 Set Preferred Units of Measure 14 2 2 3 Set Preferred Language 15 2 2 4 Set Preferred Backup Log Location 16 2 2 5 Clear Cached Settings 16 2 3 Setup H2 Classic GrainGage 17 2 3 1 Open Setup 1...

Страница 4: ...ion Calibration 43 4 2 Weigh Bucket Calibration 45 4 2 1 Calibrate Weigh Bucket 45 4 2 2 Check Weigh Bucket Calibration 48 4 3 Test Weight Calibration 48 4 3 1 Calibrate Test Weight 48 4 3 2 Check Tes...

Страница 5: ...p Data 93 5 6 1 Export Data 93 5 6 2 Export a Heat Map 95 6 Harvest Mode 99 6 1 Options for Opening Harvest Mode 99 6 2 Open Harvest Mode 99 6 3 Configure Harvest Screen Options 103 6 3 1 Configure Cy...

Страница 6: ...8 1 2 Find and Send Error Logs 124 8 2 Enable Debug Streaming 125 8 3 Common Errors 125 8 3 1 Inaccurate Plot Weight 125 8 3 2 Not Meeting Minimum Weight Threshold 126 8 3 3 Can t Connect to GrainGage...

Страница 7: ...CHAP TER ONE Mirus Ins tallation...

Страница 8: ...ge 500 MB available disk space Display Resolution 1280 x 800 or higher 1 2 Download and Install Mirus 1 2 1 Download and Activate Mirus After you have purchased a license for Mirus 1 Go to http www ha...

Страница 9: ...here is a newer version download it 5 Follow the installation instructions 1 3 Preparing the GrainGage 1 3 1 Verify GrainGage Readiness Verify the GrainGage is ready for operation by checking the foll...

Страница 10: ...To turn on the H2 Classic GrainGage 1 Start the combine 2 Activate the GrainGage by pressing the red button on the system controller 3 Open Mirus Note HarvestMaster recommends verifying the weight and...

Страница 11: ...Mirus and GrainGage S etup CHAP TER T WO...

Страница 12: ...on your Windows desktop Mirus opens the Home screen 2 1 1 Load H2 GrainGage Plugin On the Mirus Home screen 1 Tap Connect Plugin 2 Tap H2 GrainGage 3 Tap the check icon Note Mirus for H2 GrainGages d...

Страница 13: ...ecommended for setting up the H2 Classic GrainGage After adding the H2 GrainGage plugin Mirus displays an icon for the H2 GrainGage on the Main Menu screen If you upgraded Mirus to a new version befor...

Страница 14: ...Mirus and H2 Classic GrainGage Setup 2 2 Setup Mirus Preferences 2 2 1 Open Setup On the Home screen 1 Tap Setup Mirus opens the Setup screen 2 2 2 Set Preferred Units of Measure On the Setup screen 1...

Страница 15: ...nces screen 2 Tap Units of Measure 3 Select your preferred units of measure 4 Tap Save 2 2 3 Set Preferred Language On the Setup Preferences screen 1 Select Language 2 Choose your preferred language 3...

Страница 16: ...3 Tap Save Note Changing the Backup Log location is not recommended If you do change it be sure to record the new location 2 2 5 Clear Cached Settings This option can be found on the Setup Preferences...

Страница 17: ...1 Tap Setup Mirus opens the Setup screen 2 3 2 Configure Actuators Note Changing actuator times should only be done under the direction of a HarvestMaster Field Service Engineer This is especially tr...

Страница 18: ...nGage 18 Mirus and H2 Classic GrainGage Setup 2 Tap Actuator Mirus opens the Actuator Setup screen on which you can configure settings for each actuator in the GrainGage Tap Description for more infor...

Страница 19: ...ate These settings can only be changed with the help of HarvestMaster Field Service Engineers See 8 4 2 Contact a HarvestMaster Field Service Engineer on page 128 Bottom Gate Settings Setup Parameter...

Страница 20: ...te Settings Setup Parameter Default Value Description Actuator Dual The type of actuator Close Transition Time 200 msec The amount of time it takes the actuator to close the gate Limit Switch on Close...

Страница 21: ...tup 2 3 3 View GrainGage Info On the Setup H2 GrainGage screen 1 Tap Info Mirus opens the Info screen on which you can view Chamber Module and Sensor information for the H2 GrainGage 2 3 4 Configure W...

Страница 22: ...e minimum weight threshold chamber head room Mirus will not record the data because it is not likely to be accurate Evacuation Time 2000 msec The amount of time all the top and bottom gates remain ope...

Страница 23: ...b 0 227 kg This is the threshold above which a tare warning is generated after weigh bucket evacuation Note Preconfigured values are default values based on generalized harvest conditions They may not...

Страница 24: ...settings see 4 3 1 Calibrate Test Weight on page 48 2 3 6 Configure Moisture Sensors On the Setup H2 GrainGage Sensors screen 1 Tap Moisture Mirus opens the Moisture Sensor Setup screen where you can...

Страница 25: ...ntly only H2 Classics mounted on Wintersteiger Quantum or Classic Plus combines are equipped with an overflow sensor that trips when grain is in close proximity The overflow sensor should be enabled i...

Страница 26: ...26 Mirus and H2 Classic GrainGage Setup 2 3 8 Configure H2 Classic GrainGage System Settings On the Setup H2 GrainGage screen 1 Tap System Mirus opens the System Setup screen on which you can configu...

Страница 27: ...Isolation Gate Mode Normally Open Controls the initial state of the isolation gate In some situations closed is preferred Max Sub Cycle Count 1 The maximum number of sub cycles that can be run during...

Страница 28: ...ing actuator timers and weight calibrations This should only be done in consultation with a HarvestMaster Field Service Engineer 2 3 10 Update H2 Classic GrainGage Firmware This option can be found on...

Страница 29: ...for H2 Classic GrainGage 29 Mirus and H2 Classic GrainGage Setup 2 3 11 Create and Record Traits This option can be found on the Setup Traits screen To create a new trait 1 Tap the new icon Traits New...

Страница 30: ...acter limit Length and or a Default Value for quick selection Number A number trait allows the user to record a number e g a score relative to an individual plot You can set a character limit Length a...

Страница 31: ...fault Value This is the most common or most expected value for this trait Mirus will automatically populate the record field with this value to save the operator time The operator needs only to press...

Страница 32: ...H2 Clas sic GrainGage Diagnos tic s and Aler t s CHAP TER THREE...

Страница 33: ...to tare all load cells and the moisture sensor in the GrainGage 2 Allows the operator to enter and exit Glean Mode which opens all gates in the GrainGage and allows the grain to flow straight through...

Страница 34: ...he zero weight readings for the empty weigh bucket and test chamber Mirus also resets the moisture to zero Enter Glean button Use the Enter Glean button to put the GrainGage in Glean Mode This mode op...

Страница 35: ...Glean off border plots All gates are in the open position 3 Tap Exit Glean to begin measuring grain again 4 Tap the check icon to exit Diagnostics All gates are in the correct position for Harvest Mod...

Страница 36: ...ivolt readings vary linearly with weight added The empty weigh bucket causes the load cells to read between 3 and 4 mV Q This multiplier corrects the weight measurement based on the slope and motion o...

Страница 37: ...moisture curve Absolute Moisture Voltage This is the raw moisture sensor reading without any offset applied from a moisture curve This is primarily used for troubleshooting EM Frequency This is a basi...

Страница 38: ...load cell Test Weight Q This multiplier corrects the test weight measurement based on the slope and motion of the weighing platform Test Weight Tare Check Test weight value lb bu or kg hL at the time...

Страница 39: ...The Health Diagnostics screen is used by HarvestMaster Field Service Engineers 3 1 8 Actuators Diagnostics Use the Actuators Diagnostics screen to manually test the actuators controlling all gates co...

Страница 40: ...ask The problem could cause erroneous measurements data corruption data loss or some other system malfunction Warning A warning message provides cautionary information Confirmation A confirmation mess...

Страница 41: ...ide the message Or Tap the X or Clear to clear it Or Do nothing and Mirus will automatically hide the message Messages that have been hidden can be viewed again by clicking on the notifications tab on...

Страница 42: ...GrainGage Calibration CHAP TER FOUR...

Страница 43: ...1G voltage for the accelerometer inside the GrainGage This calibration is critical for good weight measurements on the moving combine It only needs to be done once a year 1 Park the combine on a leve...

Страница 44: ...e check icon to apply the new slope and motion settings 9 Tap the gear icon below the calibration wizard to open Diagnostics 10 Tap the padlock icon to extend the dialog box 11 Verify that slope and m...

Страница 45: ...ibrate Weigh Bucket Use the weight calibration wizard and the larger weight 11 lb 5 kg included with the GrainGage to calibrate the weigh bucket load cells 1 Park the combine on a level surface 2 Shut...

Страница 46: ...lue stamped on the side of the weight 10 Enter that value in the prompt 11 Tap the next arrow to initiate the calibration 12 Follow the on screen video instructions 13 Check for and remove any extra w...

Страница 47: ...he weight on the other side as directed 17 Tap the next arrow 18 Mirus displays the old and new load cell coefficients 19 Tap the next arrow 20 Remove the calibration weight 21 Tap the next arrow The...

Страница 48: ...hangers 3 The Diagnostics screen should report Weight readings that are very close to the value stamped on the calibration weight If it s not within 05 lb 23 g with the combine off HarvestMaster reco...

Страница 49: ...Select Open Calibration Wizard 8 Follow the on screen video instructions 9 Find the value stamped on the side of the weight 10 Enter that value in the prompt 11 Tap the next arrow to initiate the cal...

Страница 50: ...ight as directed 15 Tap the next arrow 16 Mirus displays the old and new load cell coefficients 17 Tap the next arrow 18 Remove the calibration weight 19 Tap the next arrow The system will tare and sh...

Страница 51: ...n 4 Tap the check icon to close Diagnostics 4 4 Moisture Curve Calibration CAUTION Do not re wet grain samples If you need to adjust the moisture content take a natural sample and dry it down Before h...

Страница 52: ...ollect and prepare samples Your challenge is to create a moisture curve that is representative of the moisture range that will be encountered during harvest The more samples available during calibrati...

Страница 53: ...ample B Wet Grain Test weight output should reflect the benchtop test weight 4 Cycle Sample B two more times 5 Sample C Dry Grain Test weight output should reflect the benchtop test weight 6 Cycle Sam...

Страница 54: ...rm up 2 Test the ambient samples in a benchtop sensor by cycling sub samples from each larger sample 3 5 times and then averaging the moisture and test weight readings This is the Known Moisture and T...

Страница 55: ...e test chamber which is important to the accuracy of the system For more information on insert counts see 7 Appendix A Standard Grain Information on page 121 11 Enable M2 0 calibration if you are harv...

Страница 56: ...t change The GrainGage cycles the grain and Mirus displays the voltage moisture percentage and test weight 18 Collect the same sample and pour it into the GrainGage again 19 Repeat the calibration cyc...

Страница 57: ...it into the GrainGage again 24 Tap Last Value to automatically populate the Known Moisture with the same value as the previous sample 25 Repeat steps 20 24 until all grain samples have been cycled thr...

Страница 58: ...rve HarvestMaster recommends testing the new moisture curve against other grain samples to confirm the moisture and test weight values 1 Test the grain sample in a benchtop sensor by cycling sub sampl...

Страница 59: ...average the moisture readings for the sample 10 If the moisture curve needs to be tuned to match the sample tap Recalibrate The Recalibrate feature is designed to adjust previously created moisture c...

Страница 60: ...Moisture percentage 14 Tap Click to run a sample 15 Repeat steps 12 14 with the same sample at least two more times Note The Last Value button can be used to fill the Known Moisture field with the pre...

Страница 61: ...c GrainGage 61 H2 Classic GrainGage Calibration 4 4 6 Test Weight Recalibration 1 Open Mirus 2 Go to Setup H2 GrainGage Moisture Curves 3 Select the moisture curve you want to test 4 Tap the edit icon...

Страница 62: ...7 Pour the grain sample into the hopper to simulate harvest Ensure the isolation gate is open so the grain drops into the GrainGage 8 Enter the Known Test Weight 9 Tap Click to run a sample 10 After...

Страница 63: ...en Mirus 2 Go to Setup H2 GrainGage Moisture Curves 3 Select the moisture curve you want to adjust 4 Tap the edit icon 5 Tap Recalibrate Adjusting the M2 0 calibration does not factor in the samples o...

Страница 64: ...e is open so the grain drops into the GrainGage 8 Enter the Known Moisture percentage 9 Tap Click to run a sample 10 Repeat steps 7 9 with the same sample at least two more times Note The Last Value b...

Страница 65: ...ves call a HarvestMaster Field Service Engineer to walk you through the adjustment See 8 4 2 Contact a HarvestMaster Field Service Engineer on page 128 1 Test the grain samples in a benchtop sensor by...

Страница 66: ...ght for more information about the moisture curve Note Only adjust these settings if a HarvestMaster Field Service Engineer tells you to 9 Cycle the same sample through the GrainGage repeat steps 7 an...

Страница 67: ...nts never adjust 0 or 1 Subtract for a negative average offset Do not adjust voltages In the example above readings from the benchtop sensor indicate that the samples have on average 1 higher moisture...

Страница 68: ...base curve as described in 4 4 3 Chamber Calibration Overview on page 52 Once you have a base curve use 3 5 samples multiple samples required that are 26 and above to manually adjust the top half of t...

Страница 69: ...heck samples starting with the lower half of the moisture curve 10 After adjusting the lower half of the curve cycle samples above 26 and repeat the adjustment procedure steps 1 8 above Only adjust th...

Страница 70: ...urve Adjusted Curve Moisture Voltage Moisture Voltage 0 0 0 000 0 0 0 000 1 0 0 400 1 0 0 400 8 0 0 793 8 0 0 793 11 0 0 892 11 0 0 892 14 0 0 990 14 0 0 990 17 0 1 089 17 0 1 089 20 0 1 187 20 0 1 18...

Страница 71: ...Field Maps CHAP TER FIVE...

Страница 72: ...Range increment is the numeric interval between ranges This will usually be 1 Range numbering begins with the bottom left corner of a field and proceeds upward In the example to the left Starting Ran...

Страница 73: ...Mirus for H2 Classic GrainGage 73 Field Maps The following instructions walk you through creation of a Range Row map On the Mirus Home screen 1 Tap Maps 2 Tap New 3 Select New Empty Map Maps New...

Страница 74: ...or the following special characters 7 Set the following Ranges deep Plots wide Range increment Plot increment Starting range Starting plot 8 Tap the check icon to save the map Mirus displays a descri...

Страница 75: ...oup of plots Rows wide indicates the number of rows within a given field Plot increment is the numeric interval between plots This will usually be 1 In the example to the left Plot increment is 1 Fiel...

Страница 76: ...plots in parallel columns The columns can be ranges horizontal or rows vertical Direction indicates the direction in which plot increments increase Note In order to collect the correct data the map p...

Страница 77: ...irus for H2 Classic GrainGage 77 Field Maps The following instructions walk you through creation of a Standard Plot ID map On the Mirus Home screen 1 Tap Maps 2 Tap New 3 Select New Empty Map Maps New...

Страница 78: ...wing special characters 7 Set the following Ranges deep Rows wide Starting plot ID Plots per replication Replication increment Plot increment Pattern Direction 8 Tap the check icon to save the map Mir...

Страница 79: ...initially displays Standard Plot ID maps as Range Row maps To display the plot IDs select Plot ID under Attribute 5 1 3 Create a Sub Map Mirus allows the creation of sub maps smaller divisions of the...

Страница 80: ...will be a sub map of 6 Tap the next arrow Note The Name box will only accept basic letters and numbers Do not use emojis or the following special characters 7 The plot and range increments are the sa...

Страница 81: ...Mirus for H2 Classic GrainGage 81 Field Maps On the Manage Maps screen Mirus displays the sub map under the main field map it is a part of Sub map...

Страница 82: ...following is an importable range row map file Note The range row map is in list format and the range and row columns are entirely numeric The column names are unimportant During the import process Mi...

Страница 83: ...GrainGage 83 Field Maps The following instructions walk you through importing a Range Row map On the Mirus Home screen 1 Tap Maps 2 Tap New 3 Select Import Map from File 4 Navigate to and select the d...

Страница 84: ...ge the columns designated as Range and Row by clicking on their respective drop down menus 6 Tap the next arrow On the Manage Maps screen Mirus displays a notification that the map has been imported s...

Страница 85: ...r text editor and saved as a tab delimited file or TXT file Do not use any headings or spaces when creating a 2D map Plot IDs may not contain any symbols Two dimensional maps need to be in TXT format...

Страница 86: ...or H2 Classic GrainGage 86 Field Maps 2 Tap New 3 Select Import Map from File 4 Navigate to and select the desired file 5 If desired change the default description displayed by Mirus 6 Tap the next ar...

Страница 87: ...us for H2 Classic GrainGage 87 Field Maps On the Manage Maps screen Mirus displays a notification that the map has been imported successfully Mirus imports the additional attributes Select to change v...

Страница 88: ...Mirus for H2 Classic GrainGage 88 Field Maps 5 2 3 Import Multiple Maps It is possible to import multiple maps at the same time On the Mirus Home screen 1 Tap Maps 2 Tap New Maps New...

Страница 89: ...s and click Open 6 Tap Yes to enable Smart Import Smart Import will import each file automatically without any additional input from the user If the map name already exists the import will stop to all...

Страница 90: ...assic GrainGage 90 Field Maps 5 3 View a Map On the Manage Maps screen 1 Select the map you want to view 2 Tap View Mirus opens the Map View screen The image below displays a map that has not yet been...

Страница 91: ...s of the grain as shown in the image below 5 4 Delete a Map On the Manage Maps screen 1 Select the map you want to delete 2 Tap Delete Mirus asks if you are sure CAUTION This cannot be undone You cann...

Страница 92: ...from year to year To do so simply copy the map in Mirus On the Manage Maps screen 1 Select the map you want to copy 2 Tap Copy 3 Enter the name and description for the map 4 Tap the check icon to save...

Страница 93: ...The heat map option creates a color coded visual map in a spreadsheet of the parameters you set for each color 5 6 1 Export Data On the Manage Maps screen 1 Select the map you want to export data from...

Страница 94: ...ur preferred Traits Note If you check Include Cycle Data the export will include sub cycle and weight trip data 7 Select EM Moisture if you would like to export the EM moisture data 8 Tap the check ic...

Страница 95: ...preadsheet for each desired attribute The colors in the heat map are determined by the Legend It can be altered by changing the minimum and maximum for each attribute For instructions see the followin...

Страница 96: ...he exported map 5 Select whether or not you want to increase color resolution 6 Select the attributes you want included in the export Multiple attributes are OK 7 Tap the check icon to finish exportin...

Страница 97: ...Mirus for H2 Classic GrainGage 97 Field Maps If Microsoft Excel is installed a spreadsheet opens automatically showing the exported heat map...

Страница 98: ...Har ves t Mode CHAP TER SIX...

Страница 99: ...arvest Note If the Harvest icon is not visible see page 12 for instructions on loading the H2 GrainGage plugin Or Tap Maps Mirus opens the Manage Maps screen From there select a map and tap Harvest Or...

Страница 100: ...the starting location 5 Select the direction of harvest 6 Choose a navigation type 7 Tap the next arrow Note If you check Enable Random Navigation you will be able to change your location on the main...

Страница 101: ...mation about configuring Traits from the Setup screen see 2 3 11 Create and Record Traits on page 29 9 Select one or all of the traits to include 10 Tap the next arrow If you selected Moisture Test We...

Страница 102: ...Mirus for H2 Classic GrainGage 102 Harvest Mode Mirus opens the Harvest screen and is ready to be configured or to collect data...

Страница 103: ...the operator to make changes to location direction and navigation type 5 Observations Opens a dialog box in which the operator can record notes for each plot during harvest This is also where you can...

Страница 104: ...e Countdown Mode 1 Tap the cycle settings icon in the toolbar 2 Select Countdown or Cycle 3 If you choose Countdown adjust the countdown time If you choose Cycle there is no countdown timer 4 Tap the...

Страница 105: ...e as follows Cycle Data Displays the plot weight moisture and test weight for each cycle Diagnostics Displays the Diagnostics dialog box for monitoring during harvest Graph Shows the plot progression...

Страница 106: ...icon If desired enlarge and shrink specific screens by dragging the borders of the Quad View screens 2 Tap the Quad View icon a second time Mirus displays options for each of the four screens 3 Tap t...

Страница 107: ...st Mode 6 3 3 Diagnostics Screen To access the Diagnostics screen in Harvest Mode 1 Tap the gear icon on the toolbar Note The Diagnostics screen will not open while the GrainGage is cycling Info Diagn...

Страница 108: ...2 Select the location on the map where you wish to resume data collection in one of two ways Tap on the plot in the map Or Enter the range and row in the fields at the top of the dialog box 3 Select a...

Страница 109: ...position and provides character fields for notes on each trait and a Quick Notes text box to record any other observations for each plot Mirus stores the quick notes and trait notes alongside harvest...

Страница 110: ...ts the map for three different traits green for weight blue for moisture and orange for test weight The values shown at the end of the graphs show the averages The green average shows the yield based...

Страница 111: ...Mirus for H2 Classic GrainGage 111 Harvest Mode 6 3 7 List View In List View you can see the data in the form of a chart...

Страница 112: ...and maximum values helps to create a more detailed legend and define the scope of the graphs and maps The narrower the minimum and maximum range the more detailed the information displayed becomes Thi...

Страница 113: ...ure attribute 3 Tap the gear icon in the Attribute bar 4 Set the Minimum and Maximum moisture 5 Tap the check icon Adjusting the minimum and maximum values helps to create a more detailed legend and d...

Страница 114: ...attribute 3 Tap the gear icon in the Attribute bar 4 Set the Minimum and Maximum Test Weight Settings 5 Tap the check icon Adjusting the minimum and maximum values helps to create a more detailed lege...

Страница 115: ...e yield per acre bu ac kg ha using the weight measurements divided by the plot area For each minimum and maximum changed the Legend will change to match the correct values Adjusting the minimum and ma...

Страница 116: ...p choose traits and a moisture curve See 6 2 Open Harvest Mode on page 99 for specifics 3 Start the thresher and throttle up 4 Tare the GrainGage if necessary 5 Tap the Start button in Mirus 6 Harvest...

Страница 117: ...times through the plot until the weight trip no longer occurs Note The amount of grain in the weigh bucket can be seen on the Real Time Weight display Make sure the weight peaks and stabilizes before...

Страница 118: ...curve See 6 2 Open Harvest Mode on page 99 for specifics 3 Start the thresher and throttle up 4 Tare the GrainGage if necessary 5 Tap the Start button in Mirus 6 Harvest the first plot 7 When the hea...

Страница 119: ...wn Note If the weight trip is triggered during the countdown the timer will continue as the GrainGage cycles If the timer has reached zero by the time the weigh cycle finishes the flush cycle will beg...

Страница 120: ...Standard Grain Information APPENDIX A...

Страница 121: ...t 63 74 oz 1885 ml 2 inserts 44 97 oz 1 330 ml Typical Weights for Test Chamber Volumes Insert Counts Grain Legume Insert Count Volume Typical Weight Wheat 60 lb bu 77 kg hL 0 82 51 oz 2 440 ml 4 05 l...

Страница 122: ...Canola 8 5 47 lb bu 60 kg hL Soybean 13 55 lb bu 71 kg hL Barley 14 5 48 lb bu 62 kg hL Corn 15 5 56 lb bu 72 kg hL Rye 14 56 lb bu 72 kg hL Sorghum 13 56 lb bu 72 kg hL Oats 13 5 32 lb bu 41 kg hL Su...

Страница 123: ...Troubleshooting APPENDIX B...

Страница 124: ...n an error has been flagged the engineers can find it easily within the error logs Use F5 to flag the error in the error log Use F6 to flag and leave a message in the error log 8 1 2 Find and Send Err...

Страница 125: ...inaccurate open Diagnostics and follow the steps listed below 1 Ensure the weigh bucket of the GrainGage is in the tracks 2 Clean inside the bucket around the bucket and around the load cells of the...

Страница 126: ...eight threshold value is outside 2 6 lb recalibrate the test weight for the chamber calibration If you are not harvesting enough grain to meet the minimum weight threshold install low yield inserts an...

Страница 127: ...30 seconds then plug them back in and attempt to connect 7 If the problem persists contact the HarvestMaster Field Service Engineers 8 3 4 Tare Warnings A tare warning can be prompted for the reasons...

Страница 128: ...on Mirus and the H2 GrainGage This instructional content includes but is not limited to M2 0 Calibration Recalibrate Traditional Moisture Curve to the New M2 0 Model in Mirus 4 3 0 Mirus Overview Weig...

Страница 129: ...Limited Warrant y APPENDIX C...

Страница 130: ...hardware or software including without limitation warranties as to merchantability fitness for a particular purpose any warranty arising from course of performance course of dealing or usage of trade...

Отзывы: