Performance Tests
hold-down the “
A
” Pushbutton on the VEGA-RC
Unit for 3 seconds to return the Unit to Test
Selection Mode.
Test T1 - Position Detection Sensor 1 A/D
Value Display Test
This test verifies the operation of Position Detec-
tion Sensor #1 (shown in Figure 2-26 on page 2-8
of Section 2 of this Manual) by displaying its
current A/D Value on the VEGA-RC Seven (7)
Segment Display. The displayable range is from
“00” to “FF” hexadecimal. The Banknote detection
threshold is set at 80H.
To perform the Position Detection Sensor #1 A/D
Value Display Test, proceed as follows:
1. On the VEGA-RC unit use Pushbutton “
B
” or
“
D
” to select Test #1 (T1).
2. Press Pushbutton “
A
” to begin the test.
3. The Seven (7) Segment Display will indicate the
current A/D Sensor’s Value as shown in Figure 6-
16.
4. If the VEGA-RC Unit currently contains any
Banknotes, verify that the displayed A/D value is
less than 80H.
5. If the VEGA-RC does not contain any Ban-
knotes, verify that the displayed A/D value is
more than 80H.
The Position Detection Sensor #1 Test is now
complete. Press and hold-down the “
A
” Push-
button on the VEGA-RC Unit for 3 seconds to
return the Unit to Test Selection Mode.
Test T2 - Position Detection Sensor 2 A/D
Value Display Test
This test verifies the operation of Position Detec-
tion Sensor #2 (shown in Figure 2-26 on page 2-8
of Section 2 of this Manual) by displaying its
current A/D Value on the VEGA-RC Seven (7)
Segment Display. The displayable range is from 00
to FF hexadecimal. The Banknote detection thresh-
old is set to a mean value of 80H.
To perform the Position Detection Sensor #2 A/D
Value Display Test, proceed as follows:
1. On the VEGA-RC unit use Pushbutton “
B
” or
“
D
” to select Test #2 (T2).
2. Press
Pushbutton
“
A
” to begin the test.
3. The Seven (7) Segment Display will indicate the
current A/D Sensor’s Value as shown in Figure 6-
17.
4. If the VEGA-RC Unit currently contains any
Banknotes, verify that the displayed A/D value is
less than 80H.
5. If the VEGA RC does not contain any Banknotes,
verify that the displayed A/D value is more than
80H.
The Position Detection Sensor #2 Test is now
complete. Press and hold-down the “
A
” Pushbut-
ton on the VEGA-RC Unit for 3 seconds to return
the Unit to Test Selection Mode.
Test T3 - Full/Empty Detection Sensors 1
& 2, and A/D Value Indication Test
This test verifies that Full/Empty Detection Sen-
sors #1 and #2 (shown in Figure 2-26 on page 2-8
of Section 2 of this Manual) are properly detecting
the Clear Film Belts (also referred to as Transport
Tapes) inside the VEGA-RC by displaying their
current A/D Values on the Seven (7) Segment
Display. The displayable range for each Sensor is
from 00 to FF hexadecimal.
To perform the Full/Empty Detection Sensors #1 &
#2, and A/D Value Indication Tests, proceed as
follows:
1. On the VEGA-RC unit use Pushbutton “
B
” or
“
D
” to select Test #3 (T3).
2. Press
Pushbutton
“
A
” to begin the Test.
3. The Seven (7) Segment Display will alternately
indicate the current A/D Values of both Sensors.
When the Green LED flashes, the displayed
value is for Full/Empty Detection Sensor #1.
When the Red LED flashes, the displayed value
is for Full/Empty Detection Sensor #2
(See Figure 6-18).
NOTE: The A/D value threshold of both
Position Detection Sensor 1 & 2 is set at
80H. If the A/D value is over 80H, both
Sensors determine that no Banknote is
detected. However, if the A/D value is less
than 80H, these Sensors determine a
Banknote is detected.
0.5 Seconds
Figure 6-16
Position Detection Sensor 1 Test
NOTE: While the A\D value is showing,
the Green LED will blink at 0.5 second
intervals.
NOTE: The A/D value threshold of both
Position Detection Sensor 1 & 2 is set to
80H. If the A/D value is over 80H, both
Sensors determine that no Banknote is
detected. However, if the A/D value is less
than 80H, these Sensors determine a
Banknote is detected.
0.5 Seconds
Figure 6-17
Position Detection Sensor 2 Test
NOTE: While the A\D value is showing, the
Green LED will blink at 0.5 second
intervals.