P/N 960-100190RA_Rev. A {EDP #148851}
© 2009, Japan CashMachine Co., Limited
2 - 6
Section 2
VEGA-RC™ BankNote Recycler Installation/Operation
C
HANGE
D
ISPLAY
To perform a VEGA-RC “Change Display” opera-
tion proceed as follows.
1. Ensure that the total number of the recyclable
Banknote within VEGA-RC is indicated on the
Seven (7) Segment Display when the Unit is in
Stand-By Mode.
2. Press
the
“
A
” [
Change Display
] Pushbutton; the
Seven (7) Segment Display flashing sequence
shown in Figure 2-20 will appear.
3. When the Storage Limit amount is indicated,
Press the “
A
” [
Change Display
] Pushbutton
again within 5 seconds.
The Seven (7) Segment Display flashing
sequence shown in Figure 2-21 will appear.
Refer to Table 2-3 and Figure 2-22 for examples
of a Euro (
€
) denomination stacking operation.
S
TORAGE
L
IMITATION
1. The Seven (7) Segment Display flashing
sequence previously shown in Figure 2-20 will
re-appear by pressing the “
A
” [
Change Display
]
Pushbutton (Review the Figure 2-20 display).
2. When pressing the “
C
” [
Restore
] or “
B
” [
Dis-
pense
] Pushbuttons while the Seven (7) Segment
Display shows the Storage Limit Value, the limit
value can be set to any value desired between 1 &
30 (e.g., Figure 2-23 shows a Limit set value of
28).
The new storage limit data value will be
written into EEPROM within 5 seconds after
the “
D
” [
Retrieve
] Pushbutton is pressed.
Table 2-3
Stacking Denomination Example Table
Typical
Denomination
7 Segment Indicator
Left
Right
€1
0
1
€100
1
A
€500
5
A
€1000
1
B
€2000
2
B
€10000
1
C
0.5 Seconds
Interval
Figure 2-20
Storage Limit (30 LImit)
Interval
0.5 Seconds
Figure 2-21
Storage Limit/Stacked (20 Money
Class)
NOTE: If the storage limit or stacking
denomination operation is not started within
five (5) seconds of the button push, the
VEGA-RC status will return to the Stand-By
Mode.
5 Euros
10 Euros
500 Euros
Figure 2-22
Stacking € Denomination Examples
NOTE: After showing the storage limit value
for five (5) seconds, the VEGA-RC status will
return to the Stand-By Mode.
Interval
0.5 Seconds
Figure 2-23
Storage Limit Value Set at 28
LImit)
NOTE: Reducing the storage limit value by
one (-1) can be accomplished by pressing
the “C” [Restore] Pushbutton once per
declination, and increasing the storage limit
value by one (+1) can be accomplished by
pressing “B” [Dispense] Pushbutton once
per inclination.
Pressing the “C” [Restore] Pushbutton
when the Seven (7) Segment Display is
showing thirty (30), will cause the count
indicator to roll-over to “00”.
The Storage Limit setting range is therefore
00 to 30. If the Storage Limit setting is “00”,
the storage limit value will depend on the
Stacker Full Sensor’s limit detection. If the
storage limit is set between 01 and 30, the
specified number set is the desired storage
limit setting obeyed.
NOTE: If the “D” [Retrieving] Pushbutton is
not pressed within 5 seconds after setting
the new storage limit value, the new setting
value is not recorded and the VEGA-RC
Unit will return to the Stand-By Mode.