P/N 960-100190RA_Rev. A {EDP #148851}
© 2009, Japan CashMachine Co., Limited
6 - 4
Section 6
VEGA-RC™BankNote Recycler
Performance Tests
4. On the VEGA-RC DIP Switch, set Switches #1,
#3, #5 and #7 to ON and Switches #2, #4, #6 and
#8 to OFF. The Seven (7) Segment Display
should indicate “
DS
” followed by “
55
”.
5. On the VEGA-RC DIP Switch set Switches #1,
#3, #5 and #7 to OFF and Switches #2, #4, #6
and #8 to ON. The Seven (7) Segment Display
should indicate “
DS
” followed by “
AA
”.
6. On the VEGA-RC DIP Switch, set Switches #1
through #8 to ON. The Seven (7) Segment Dis-
play should indicate “
DS
” followed by “
FF
”.
The DIP Switch Test is now complete. Press and
hold the “
A
” Pushbutton down for 3 seconds to
return the unit to Test Selection Mode. Figure 6-7
and Table 6-2 illustrates a typical DIP Switch Test
Display.
Rear Cover Sensor Test
This test is performed to make sure that the Rear
Cover Sensors work properly. Open the Rear
Cover. When the Rear Cover functions normally,
one of the Seven (7) Segment Displays shown in
Figure 6-8 or Figure 6-9 will appear.
To perform the Rear Cover Sensor Test proceed as
follows:
1. Use Pushbutton “B” or “D” to select Test Zero
(T0).
2. Press
Pushbutton
“
A
”. The Seven (7) Segment
Display should indicate “
TS
” followed by “
01
”.
3. Open the Rear Cover of the VEGA-RC and
verify that the Seven (7) Segment Display indi-
cates a “
door open
” message (
dr oP
) as shown in
Figure 6-8.
4. Close the Rear Cover of the VEGA-RC and ver-
ify that the Seven (7) Segment Display indicates
a “
door closed
” message (
dr CL
)as shown in Fig-
ure 6-9.
The Rear Cover Sensor Test is now complete.
Press and hold-down the “
A
” Pushbutton for 3
seconds to return the Unit to the Test Selection
Mode.
VEGA E
SCROW
S
ENSOR
, VEGA S
TACK
-I
N
S
EN
-
SOR
AND
VEGA-RC F
LAP
S
ENSOR
I
NPUT
T
ESTS
These tests are performed in order to check proper
operation of the VEGA Escrow Sensor, the VEGA
Stack-In Sensor, and the VEGA-RC Flap Sensor.
Refer to Figure 2-10 on page 2-5 of the “VEGA
Operation and Maintenance Manual” to verify the
location of each Sensor prior to testing them.
Perform the following steps to verify their proper
operation.
VEGA Escrow Sensor Input Test
This test is performed to verify the VEGA Escrow
Sensors’ status. Before proceeding, perform the
Light Interception and Transmissive Tests of the
VEGA Unit’s Escrow Sensors.
To perform the VEGA Unit Escrow Sensor Test,
proceed as follows:
1. Use Pushbutton “B” or “D” on the VEGA-RC to
select Test Zero (T0).
2. Press
Pushbutton
“
A
”. The Seven (7) Segment
Display should indicate “
TS
” followed by “
01
”.
3. On the VEGA BV Unit, press in on the Upper
Section Open/Close Buttons (review Figure 1-4 c
of the VEGA BV Service Manual), and lift open
the Upper Section approximately 3 to 4 inches.
Verify that the Seven (7) Segment Display
indicates a “
Sensor OFF
” condition as shown in
Figure 6-10.
Table 6-2
Typical DIP Switch Test Indications
DIP Switch: All OFF
DIP Switch No.
8
7
6
5
4
3
2
1
Binary Digit
0
0
0
0
0
0
0
0
7 Segment Display
DIP Switch: 3, 6, 8 ON
DIP Switch No.
8
7
6
5
4
3
2
1
Binary Digit
1
0
1
0
0
1
0
0
7 Segment Display
DIP Switch: All ON
DIP Switch No.
8
7
6
5
4
3
2
1
Binary Setting
1
1
1
1
1
1
1
1
7 Segment Display
0.5 Seconds
Figure 6-7
Typical DIP Switch Test Display
0.5 Seconds
Figure 6-8
Rear Cover Open (dr oP)
0.5 Seconds
Figure 6-9
Rear Cover Closed (dr CL)