PAGE 25 of 140
DP0029 Rev 02.2
4.3.3. SKOOT HT Umbilical
The umbilical is the backbone of the system,
connecting the crawler to the power controller.
While designed for high temperature operation,
the umbilical must be protected in the high
temperature cable management at all times.
4.3.4. Handheld Controller
The handheld controller is used to manipulate a
scanner installed on an inspection surface. User
settings and scan information are edited using the
handheld controller.
The handheld controller is not watertight and
is not intended to be used in extremely wet
environments. The handheld controller utilizes a
resistive touch screen, care should be taken to not
use sharp or gritty objects on the screen as the
touch membrane can scratch. If the screen is damaged, all programmed functions
can still be accessed using the D-pad.
NOTE:
Do
NOT
connect the handheld controller while system activated.
4.3.5. Manipulation Handle
The manipulation handle is used to assist with the
placement of the crawler onto the scan surface.
As well, the manipulation handle can be used to
make small adjustments to the direction of the
crawler's travel.
Fig. 47 - SKOOT HT umbilical
CAUTION!
DO NOT DISCONNECT
UNDER LOAD.
Shut off power before connection or
disconnecting. Permanent damage to electronics
could occur.
WARNING!
MAGNETIC MATERIAL.
The
handheld controller contains magnetic material.
Those with pacemakers or ICD’s must stay at least
10 cm
(4 in)
away.
Fig. 48 - Handheld controller
Fig. 49 - Manipulation handle