Instruction manual JetCat-PRO engines, 1.7 - V12.01V
The RUN Menu
As soon as the ECU is switched on, the
Run
menu is displayed.
In the lower display line, the actual engine RPM is indicated.
In the upper display line, the following selections can be monitored. Use the
+ / -
buttons alone for selecting the
different parameters.
Value
Explanation
Temp.
Current EGT (
E
xhaust
G
as
T
emperature).
The units, °C or °F can be selected in the LIMITs menu.
OffCnd
SetRpm
Last Off command (reason for shut down). See table on page 28
State
Current engine state.
U-Pump
Current pump voltage.
Airspeed
Current Air speed (km/h) this readout is usual for function check of the speed sensor.
Note: This readout is only supported by connected airspeed sensor.
Set Speed
Target state-air speed (km/h). This readout is for checking at the “speed control” mode the set
target state-airspeed of throttle stick.
Note: This readout is only supported by connected airspeed sensor.
The Min/Max Menu
The Min/Max menu is used primarily for diagnostics purposes. All the following variables may be sampled manually by
pressing the
Change Value/Item
button on the GSU.
Value
Explanation
Upump-Max
Upump-Min
Maximum pump voltage.
Minimum pump voltage.
MaxTemp
MinTemp
Maximum EGT.
Minimum EGT.
MaxRpm
MinRpm
Maximum engine RPM.
Minimum engine RPM.
MaxAirSpd
AvgAirSpd
Maximum Airspeed (*)
Average Airspeed (*)
Flight Distance
Flight distance in km (*)
AvgRpm
MaxRTmp
Average-RPM
Average temperature at full throttle
AvgPump
AvgTemp
Average pump voltage
Average temperature
(*) Only by connected air speed sensor!